Cellular heterogeneity is of significance in cell-based assays for life science, biomedicine and clinical diagnostics. Electrical impedance sensing technology has become a powerful tool, allowing for rapid, non-invasive, and label-free acquisition of electrical parameters of single cells. These electrical parameters, i.e., equivalent cell resistance, membrane capacitance and cytoplasm conductivity, are closely related to cellular biophysical properties and dynamic activities, such as size, morphology, membrane intactness, growth state, and proliferation. This review summarizes basic principles, analytical models and design concepts of single-cell impedance sensing devices, including impedance flow cytometry (IFC) to detect flow-through single cells and electrical impedance spectroscopy (EIS) to monitor immobilized single cells. Then, recent advances of both electrical impedance sensing systems applied in cell recognition, cell counting, viability detection, phenotypic assay, cell screening, and other cell detection are presented. Finally, prospects of impedance sensing technology in single-cell analysis are discussed.
We present a microfluidic cell-culture chip that enables trapping, cultivation and release of selected individual cells. The chip is fabricated by a simple hybrid glass-SU-8-PDMS approach, which produces a completely transparent microfluidic system amenable to optical inspection. Single cells are trapped in a microfluidic channel using mild suction at defined cell immobilization orifices, where they are cultivated under controlled environmental conditions. Cells of interest can be individually and independently released for further downstream analysis by applying a negative dielectrophoretic force via the respective electrodes located at each immobilization site. The combination of hydrodynamic cell-trapping and dielectrophoretic methods for cell releasing enables highly versatile single-cell manipulation in an array-based format. Computational fluid dynamics simulations were performed to estimate the properties of the system during cell trapping and releasing. Polystyrene beads and yeast cells have been used to investigate and characterize the different functions and to demonstrate biological compatibility and viability of the platform for single-cell applications in research areas such as systems biology.
As a complement and alternative to optical methods, wide-band electrical impedance spectroscopy (EIS) enables multi-parameter, label-free and real-time detection of cellular and subcellular features. We report on a microfluidics-based system designed to reliably capture single rod-shaped Schizosaccharomyces pombe cells by applying suction through orifices in a channel wall. The system enables subsequent culturing of immobilized cells in an upright position, while dynamic changes in cell-cycle state and morphology were continuously monitored through EIS over a broad frequency range. Besides measuring cell growth, clear impedance signals for nuclear division have been obtained. The EIS system has been characterized with respect to sensitivity and detection limits. The spatial resolution in measuring cell length was 0.25 μm, which corresponds to approximately a 5-min interval of cell growth under standard conditions. The comprehensive impedance data sets were also used to determine the occurrence of nuclear division and cytokinesis. The obtained results have been validated through concurrent confocal imaging and plausibilized through comparison with finite-element modeling data. The possibility to monitor cellular and intracellular features of single S. pombe cells during the cell cycle at high spatiotemporal resolution renders the presented microfluidics-based EIS system a suitable tool for dynamic single-cell investigations.
11 July 2014 in Analytical and Bioanalytical Chemistry
This paper reports a versatile and irreversible bonding method for poly(dimethylsiloxane) (PDMS) and SU-8. The method is based on epoxide opening and dehydration reactions between surface-modified PDMS and SU-8. A PDMS replica is first activated via the low-cost lab equipment, i.e., the oxygen plasma cleaner or the corona treater. Then both SU-8 and plasma-treated PDMS samples are functionalized using hydrolyzed (3-aminopropyl)triethoxysilane (APTES). Ultimately, the samples are simply brought into contact and heated to enable covalent bonding. The molecular coupling and chemical reactions behind the bonding occurring at the surfaces were characterized by water contact angle measurement and X-ray photoelectron spectroscopy (XPS) analysis. The reliability of bonded PDMS-SU-8 samples was examined by using tensile strength and leakage tests, which revealed a bonding strength of over 1.4 MPa. The presented bonding method was also applied to create a metal-SU-8-PDMS hybrid device, which integrated SU-8 microfluidic structures and microelectrodes. This hybrid system was used for the effective trapping of microparticles on-chip, and the selective releasing and identification of predefined trapped microparticles. The hybrid fabrication approach presented here, based on the PDMS-SU-8 bonding, enables multifunctional integration in complex microfluidic devices.