Simple sensor-based procedures, including auscultation and electrocardiography (ECG), can facilitate early diagnosis of valvular diseases, resulting in timely treatment. This study assessed the impact of combining these sensor-based procedures with machine learning on diagnosing valvular abnormalities and ventricular dysfunction. Data from auscultation at three distinct locations and 12-lead ECGs were collected from 1052 patients undergoing echocardiography. An independent cohort of 103 patients was used for clinical validation. These patients were screened for severe aortic stenosis (AS), severe mitral regurgitation (MR), and left ventricular dysfunction (LVD) with ejection fractions ≤ 40%. Optimal neural networks were identified by a fourfold cross-validation training process using heart sounds and various ECG leads, and their outputs were combined using a stacking technique. This composite sensor model had high diagnostic efficiency (area under the receiver operating characteristic curve (AUC) values: AS, 0.93; MR, 0.80; LVD, 0.75). Notably, the contribution of individual sensors to disease detection was found to be disease-specific, underscoring the synergistic potential of the sensor fusion approach. Thus, machine learning models that integrate auscultation and ECG can efficiently detect conditions typically diagnosed via imaging. Moreover, this study highlights the potential of multimodal artificial intelligence applications.
Introduction: Periprocedural oral anticoagulation (OAC) strategies for atrial fibrillation (AF) ablation procedures are changing rapidly. Objective: To assess the management and course of periprocedural OAC for AF ablation procedures in experienced electrophysiology (EP) centers in Germany over the last 12 months. Methods: The data are based on an electronic questionnaire, which was sent to 35 experienced EP centers in September 2018 and then exactly 1 year later. Participants provided information on their periprocedural OAC management, the handling with dual therapy (OAC plus single antiplatelet therapy), the availability of specific antidotes, the transseptal puncture approach, and noteworthy complications. Results: Responses were received from all 35 centers and represent 10,010 AF ablation procedures annually. In 2018, the administration of vitamin K antagonist (VKA) was continued throughout the procedure at all centers (100%). In contrast, the majority of centers used minimally interrupted periprocedural non-vitamin K antagonist oral anticoagulants (NOAC) (54.3%), 13 centers (37.2%) completely interrupted NOAC, and only 3 centers (8.5%) continued NOAC throughout the procedure. At the 1-year follow-up survey, 32 centers were found to have continued their previous strategy of periprocedural OAC and 3 changed from a minimally interrupted to a continued NOAC strategy. Of note, 30 centers (85.7%) performed transseptal puncture fluoroscopically without additional cardiac imaging. In the setting of uninterrupted periprocedural OAC management, no relevant complications were noted. Conclusion: Our survey shows marked heterogeneous periprocedural OAC management at experienced EP centers in Germany. Whereas continuation of VKA has already been integrated into clinical practice, the majority of centers still use a minimally interrupted NOAC strategy.
8 February 2024 in Journal of Cardiovascular Electrophysiology
Introduction: Pulsed field ablation (PFA) has emerged as an innovative technique for pulmonary vein isolation (PVI). Typically, a transeptal puncture (TSP) with a standard sheath precedes a switch to the larger diameter sheath in the left atrium. This study aimed to describe the safety and feasibility of direct TSP using the large diameter Faradrive sheath before performing PVI with PFA.Methods: We prospectively enrolled 166 consecutive patients with paroxysmal or persistent atrial fibrillation (AF) undergoing PVI with PFA at our institution. TSP was performed in all cases with transesophageal echocardiography guidance, using the Faradrive sheath and a 98 cm matched Brockenbrough needle. The primary endpoint was the occurrence of pericardial tamponade during or within the first 48 h after the procedure. The secondary endpoint was the occurrence of any major complication.Results: All 166 patients were included into the final analysis (44% female): 64% of patients had paroxysmal AF and 36% persistent AF (68 ± 11 years old, median CHA2DS2Vasc Score 3, median left atrial volume index 31). The median duration of the procedure was 60 min, median time to TSP was 15 min, and the median fluoroscopy dose was 595 cGy × cm2. The primary endpoint occurred in one patient: a non‐TSP related pericardial tamponade, which was managed with pericardial puncture.Conclusion: Direct TSP with skipping sheath exchange using the large diameter Faradrive sheath for PVI with PFA was safe, feasible, and reduced costs in all patients. Large scale studies and registries are needed to verify this workflow.
20 January 2026 in Journal of Cardiovascular Electrophysiology
Background: Pulsed field ablation (PFA) is a novel, non‐thermal ablation modality to achieve pulmonary vein isolation (PVI) for the treatment of atrial fibrillation (AF). For the pentaspline catheter, eight applications per pulmonary vein (PV) are considered standard, with four in basket configuration and four in flower configuration. The objective of the study is to investigate whether pentaspline PFA using 16 applications per PV is associated with an improved outcome compared with the standard procedure. Methods: The prospective study included a total of 292 patients with AF. According to the number of applications per PV, patients were assigned to group PFA‐8 (8 applications per PV; 4x basket configuration, 4x flower configuration; n = 130) or group PFA‐16 (16 applications per PV; 6x basket, 10x flower; n = 162). The primary endpoint was freedom from atrial arrhythmia (AA), i.e. AF, atrial flutter, and atrial tachycardia, after a follow‐up period of 1 year, as assessed by Holter monitoring after 3 and 12 months, respectively. Results: Freedom from AA was significantly higher in group PFA‐16 than in group PFA‐8 (73.9% vs. 62.3%; p < 0.05). Subgroup analysis showed greater effectiveness in the PFA‐16 group than in the PFA‐8 group (66.1% vs. 45.3%; p < 0.05) in patients with persistent AF, while freedom from AA was similar in both groups in patients with paroxysmal AF (78.8% in PFA‐16 vs. 75.7% in PFA‐8; p = ns). Serious adverse events were observed in 8 (2.7%) patients, with no differences between the two groups. Conclusion: PVI using 16 PFA applications per PV may improve clinical outcome in patients with persistent AF.
Recent studies highlight artificial intelligence’s ability to identify ventricular dysfunction via electrocardiograms (ECGs); however, specific indicative waveforms remain unclear. This study analysed ECG and echocardiography data from 17,422 cases in Japan and Germany. We developed 10-layer convolutional neural networks to detect left ventricular ejection fractions below 50%, using four-fold cross-validation. Model performance, evaluated among different ECG configurations (3 s strips, single-beat, and two-beat overlay) and segments (PQRST, QRST, P, QRS, and PQRS), showed two-beat ECGs performed best, followed by single-beat models, surpassing 3 s models in both internal and external validations. Single-beat models revealed limb leads, particularly I and aVR, as most indicative of dysfunction. An analysis indicated segments from QRS to T-wave were most revealing, with P segments enhancing model performance. This study confirmed that dual-beat ECGs enabled the most precise ventricular function classification, and segments from the P- to T-wave in ECGs were more effective for assessing ventricular dysfunction, with leads I and aVR offering higher diagnostic utility.
Performing repeated pulmonary vein isolation (re-PVI) after recurrent atrial fibrillation (AF) following prior PVI is a standard procedure. However, no consensus exists regarding the most effective approach in redo procedures. We assessed the efficacy of re-PVI using wide antral circumferential re-ablation (WACA) supported by high-density electroanatomical mapping (HDM) as compared to conventional re-PVI. Consecutive patients with AF recurrences showing true PV reconnection (residual intra-PV and PV antral electrical potentials within the initial ablation line) or exclusive PV antral potentials (without intra-PV potentials) in the redo procedure were prospectively enrolled and received HDM-guided WACA (Re-WACA group). Conventional re-PVI patients treated using pure ostial gap ablation guided by a circular mapping catheter served as a historical control (Re-PVI group). Patients with durable PVI and no antral PV potentials were excluded. Arrhythmia recurrences ≥30 s were calculated as recurrences. In total, 114 patients were investigated (Re-WACA: n = 56, 68 ± 10 years, Re-PVI: n = 58, 65 ± 10 years). There were no significant differences in clinical characteristics including the AF type or the number of previous PVIs. In the Re-WACA group, 11% of patients showed electrical potentials only in the antrum but not inside any PV. At 402 ± 71 days of follow-up, the estimated freedom from arrhythmia was 89% in the Re-WACA group and 69% in the Re-PVI group (p = 0.01). Re-WACA independently predicted arrhythmia-free survival (HR = 0.39, 95% CI 0.16–0.93, p = 0.03), whereas two previous PVI procedures predicted recurrences (HR = 2.35, 95% CI 1.20–4.46, p = 0.01). The Re-WACA strategy guided by HDM significantly improved arrhythmia-free survival as compared to conventional ostial re-PVI. Residual PV antral potentials after prior PVI are frequent and can be easily visualized by HDM.