It is important to estimate the current magnitude and charge amount of a partial discharge (PD) in a gas‐insulated switchgear (GIS). In this study, electromagnetic fields generated by a PD in an 84 kV‐class three‐phase GIS for testing have been measured with a voltage probe installed on the outer surface of an insulation spacer of the GIS tank, and the corresponding simulations have been carried out using the three‐dimensional finite‐difference time‐domain (FDTD) method. FDTD‐computed time‐domain voltages across spacers agree reasonably well with the corresponding measured ones, and the current magnitude of PD and its charge amount have been estimated.
Endoscopic-ultrasonography-guided tissue acquisition (EUS-TA) has been widely performed for the definitive diagnosis of solid pancreatic lesions (SPLs). As the puncture needles, puncture techniques, and sample processing methods have improved, EUS-TA has shown higher diagnostic yields and safety. Recently, several therapeutic target genomic biomarkers have been clarified in pancreatic ductal carcinoma (PDAC). Although only a small proportion of patients with PDAC can benefit from precision medicine based on gene mutations at present, precision medicine will also be further developed for SPLs as more therapeutic target genomic biomarkers are identified. Advances in next-generation sequencing (NGS) techniques enable the examination of multiple genetic mutations in limited tissue samples. EUS-TA is also useful for NGS and will play a more important role in determining treatment strategies. In this review, we describe the utility of EUS-TA for SPLs.
16 March 2011 in Analytical and Bioanalytical Chemistry
It is sometimes difficult to distinguish between malignant and benign biliary strictures using imaging studies alone, and pathological diagnosis is necessary. The aim of this study was to determine the usefulness of endoscopic transpapillary tissue sampling and factors predictive of diagnostic accuracy. From April 2008 to December 2014, 136 patients underwent endoscopic transpapillary tissue sampling for malignant biliary strictures. The cytological and histological findings were reported as negative, suspicious, or positive. Suspicious and positive findings were defined as pathologically positive. The sensitivity was 65.0% for forceps biopsy, 49.5% for brush cytology, 46.2% for bile aspiration cytology, and 21.9% for endoscopic nasobiliary drainage cytology. The combination of these procedures improved the sensitivity (72.8%). Endoscopic transpapillary tissue sampling was more sensitive for lesions of biliary origin (91.4%) than for extrabiliary lesions (66.3%). In surgical cases, the sensitivity for tumors with an infiltrative growth pattern (53.3%) was significantly lower than for a tumor with an expanding or intermediate growth pattern (87.5%). Combining procedures can improve diagnostic accuracy. It may be possible to predict the sensitivity of endoscopic transpapillary tissue sampling by evaluating the etiology and tumor growth pattern using preoperative imaging studies.
6 October 2015 in Clinical Journal of Gastroenterology