Zhixuan Er

Dr. Zhixuan Er

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2024 in Optics and Lasers in Engineering
Verified
Journal Article
Closed access
ZEZhixuan Er
Zhixuan Er
PGPing Gong
Ping Gong
JZJian Zhou
Jian Zhou
YCYang Chang
Yang Chang
YJYu Ju
Yu Ju
LXLiang Xie
Liang Xie

11 March 2022 in Photonics
Verified
Journal Article
Open access
PDF file
PGPing Gong
Ping Gong
JZjian Zhou
jian Zhou
ZEZhixuan Er
Zhixuan Er
YJYu Ju
Yu Ju
XLXie Liang
Xie Liang
In this paper, a single humidity sensor for water vapor and heavy oxygen water vapor detection is presented. The sensor is based on tunable diode laser absorption spectroscopy (TDLAS) and thus has high sensitivity, good selectivity, and a short response time. A 1372 nm distributed feedback (DFB) diode laser is utilized as the light source, the wavelength tuning range of which covers the absorption lines of water vapor and heavy oxygen water vapor. A Herriott gas cell with 12 m optical length is designed for signal-to-noise ratio (SNR) enhancement. The sensor can distinguish between water vapor and heavy oxygen water vapor effectively. The accuracy of water detection is within ±0.5% RH. The accuracy of heavy oxygen water vapor detection is within ±1.0% RH.

25 May 2022 in Applied Optics
Verified
Journal Article
Closed access
PDF file
ZEZhixuan Er
Zhixuan Er
PGPing Gong
Ping Gong
JZJian Zhou
Jian Zhou
YWYiming Wang
Yiming Wang
XJXiaokang Jiang
Xiaokang Jiang
XLXie Liang
Xie Liang
Measurement of dissolved oxygen (DO) in liquid samples is of vital importance in both industrial and biomedical fields. In this paper, a DO sensor based on the fluorescence quenching method has been built. The measurement principle is based on fluorescence lifetime detection, which is indicated by the phase difference between an excitation light signal and a fluorescence signal. The nonlinear effect of the fluorescent material has been taken into consideration to obtain a more accurate fitting model. The performance of the system varying with the modulation frequency of excitation light signals is also reported. Modulation frequency mainly affects the sensitivity and phase resolution ratio of the system. The system at the optimized modulation frequency has a good degree of fitting with R 2 value of 0.9981 and a small relative error of 0.79%. The study shows that this kind of sensor with optimal modulation frequency has good performance, which can be used in many important fields.