Ping Gong

Ms. Ping Gong


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2021 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
PGPing Gong
Ping Gong
XJXiaokang Jiang
Xiaokang Jiang
JZJian Zhou
Jian Zhou
XLXie Liang
Xie Liang
In this letter, a wavelength-tunable Optical Time-Domain Reflectometer (OTDR) for Dense Wavelength Division Multiplexing Passive Optical Network (DWDM-PON) is proposed and experimentally demonstrated. An Integrated Tunable Laser Assembly (ITLA) serves as the light source permitting measurements of 80 DWDM channels in the C-band. Dither modulation is added to ITLA to depress coherent noise resulted from the narrow linewidth of the light source. Semiconductor Optical Amplifier (SOA) modulates the continuous light into pulsed light and meanwhile amplifies peak optical power of the pulsed light to 13 dBm. In addition, we optimize the wavelet denoising algorithm for further signal-noise ratio (SNR) enhancement. Dynamic range and spatial resolution of the proposed OTDR reach up to 16.2 dB and 2 m respectively. A DWDM-PON fiber link including an Arrayed Waveguide Grating (AWG) is measured to verify the system performances, and the OTDR profiles of different channels coincide with each other. The designed wavelength-tunable OTDR is shown to be appropriate for DWDM-PON.

28 December 2022 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
YJYuxuan Jiang
Yuxuan Jiang
MJMingqi Jiao
Mingqi Jiao
CLCongbiao Lei
Congbiao Lei
JYJiaqi Yao
Jiaqi Yao
WYWenyang Yuan
Wenyang Yuan
XLXie Liang
Xie Liang
This letter proposes a simple method for measuring frequency responses of photodetectors (PDs) based on the multiple harmonic responses of a direct-modulated laser (DML). This method provides numerous harmonics as carriers for subsequent Mach–Zehnder modulator (MZM) modulation based on the nonlinear effect of the direct modulation laser. The modulated signal is injected into the photodetector under test, and the frequency response of the photodetector detector is obtained by sampling the MZM modulation component around multiple harmonics on the electronics spectrum analyzer (ESA). By measuring the relative amplitude of the modulation components around different harmonics, measurement error caused by harmonic amplitude differences can be eliminated. This method greatly expands the measurement range of the frequency response from DC to 2nfm. Moreover, since the modulator modulation frequency range occupies only $\frac {1}{2{\mathrm {n}}}$ of the entire measurement range, the uneven frequency response caused by the modulator is reduced, and extra calibration is avoided. According to this method, we use a 35GHz Mach-Zehnder modulator to measure the frequency response of photodetectors with the bandwidth of 35GHz and 50GHz, respectively. We also compared our method with those conventional methods, and the results show that the method which has a wide frequency response can accurately measure the frequency response of the PD under the condition of the method.

10 November 2022 in Photonics
Verified
Journal Article
Open access
PDF file
JYJiaqi Yao
Jiaqi Yao
YWyuan wenyang
yuan wenyang
PGPing Gong
Ping Gong
XLXie Liang
Xie Liang
A frequency division multiplexing (FDM) WMS system for multi-gas detection is reported in this paper. The distributed feedback lasers with different wavelengths adopt different modulation frequencies to achieve multi-components gas detection by the FDM technology. Combining optical path extension, normalized harmonic detection and wavelength modulation spectroscopy technology, the highly self-made system realized high sensitivity, high precision and short response time. The performance of this system was evaluated through the mixed gas of methane and hydrogen chloride. Experimental results show great linear response between gas concentration and normalized second harmonic (2f/1f) signal, the minimum detection limit (MDL) of the system is calculated to be 30.16 ppb for CH4 and 31.6 ppb for HCl with the integration time of 15 s. The MDL could be further enhanced to 11 ppb for CH4 and 13.1 ppb for HCl with an extended integration time. The maximum relative error is 2.16% and 3.19% for CH4 and HCl respectively.

12 April 2023 in Atmosphere
Verified
Journal Article
Open access
PDF file
YWyuan wenyang
yuan wenyang
JYJiaqi Yao
Jiaqi Yao
PGPing Gong
Ping Gong
MJMingqi Jiao
Mingqi Jiao
CLCongbiao Lei
Congbiao Lei
XLXie Liang
Xie Liang
In this paper, a compact ambient gas sensor with an optimized photoacoustic cell is reported. The relationship between the geometric dimensions (usually radius and length) of the photoacoustic cell (PAC) and the acoustic signal was studied through theoretical and finite element analysis. Then an optimized H-type PAC with a volume of 80 mm × 30 mm × 30 mm was machined out. The gas capacity is only 18.85 millilitres. The performance of the photoacoustic cell has been verified experimentally by the detection of nitrogen dioxide (NO2) standard gas. With an electret microphone and an economically self-designed 450 nm laser module, the detection of NO2 concentration was executed. The experimental results show good linearity with a fitting R-square of 0.9991. With an SNR (signal-to-noise ratio) of 41.247, the minimum detection limit (MDL) of the system can reach 4.85 ppb (1σ). With an analysis of allan variance, the MDL can achieve 0.11 ppb with a 228 s integration time. By replacing the light source, the system shows great potential for sensitive and compact detectors for other ambient gasses as well.

5 March 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YJYuxuan Jiang
Yuxuan Jiang
CLChangming Liu
Changming Liu
SLShirong Lv
Shirong Lv
CLCongbiao Lei
Congbiao Lei
GZGuangcheng Zhong
Guangcheng Zhong
XLXie Liang
Xie Liang
The multimode thru-reflect-line (TRL) algorithm is widely used for on-wafer differential circuit calibration. This paper presents the design and calibration of coplanar grounded waveguide (GCPW) based calibration kits. Based on the original algorithm, we optimise the reflect standard symbol determination algorithm. The impedance transformation algorithm is added so that the algorithm can be applied to calibrating strongly coupled devices. An improved algorithm and the designed calibration kits enabled precise calibration from 0.1 GHz to 110 GHz. The conventional multimode TRL algorithm line standards have a narrow calibration range and require manual selection. In this paper, an algorithm for selecting line standards is proposed, which automatically selects line standards with minor errors and expands the calibration frequency of line standards. Finally, the error of the improved multimode TRL algorithm is quantitatively analysed and discussed.

11 March 2022 in Photonics
Verified
Journal Article
Open access
PDF file
PGPing Gong
Ping Gong
JZjian Zhou
jian Zhou
ZEZhixuan Er
Zhixuan Er
YJYu Ju
Yu Ju
XLXie Liang
Xie Liang
In this paper, a single humidity sensor for water vapor and heavy oxygen water vapor detection is presented. The sensor is based on tunable diode laser absorption spectroscopy (TDLAS) and thus has high sensitivity, good selectivity, and a short response time. A 1372 nm distributed feedback (DFB) diode laser is utilized as the light source, the wavelength tuning range of which covers the absorption lines of water vapor and heavy oxygen water vapor. A Herriott gas cell with 12 m optical length is designed for signal-to-noise ratio (SNR) enhancement. The sensor can distinguish between water vapor and heavy oxygen water vapor effectively. The accuracy of water detection is within ±0.5% RH. The accuracy of heavy oxygen water vapor detection is within ±1.0% RH.