The necessity of ensuring the long-term sustainability of existing structures is rising. An important issue concerning existing reinforced concrete (RC) structures in seismically active regions is that a significant number of them lack the required earthquake-resistant capacities to meet the increased design earthquake demands. Inexpensive, fast and long-term strengthening strategies for repairing/strengthening RC structures are urgently required, not only after destructive earthquakes, but even before they occur. Retrofitting existing buildings extending their service life rather than demolishing and rebuilding new ones is the best option in terms of economic gain and environmental protection. This paper experimentally investigates the effectiveness of externally applied (i) carbon fiber-reinforced polymer (C-FRP) ropes in X-type form and (b) C-FRP sheets that are bonded on both sides of the joint area of RC beam-column joint connections. Six comparative full-scale exterior RC beam-column joint specimens were tested under reverse cyclic deformation. Two of them were control specimens, two were strengthened using C-FRP ropes (novel technique) and two were retrofitted using C-FRP sheets (widely used technique). Extensive comparisons and discussion of the test results derive new quantitative and qualitative results concerning the seismic capacity and the service life extension of the strengthened RC members using the proposed retrofitting scheme.
Recent research has indicated that the implantation of a network of piezoelectric transducer patches in element regions of potential damage development, such as the beam–column joint (BCJ) area, substantially increases the efficacy and accuracy of the structural health monitoring (SHM) methods to identify damage level, providing a reliable diagnosis. The use of piezoelectric lead zirconate titanate (PZT) transducers for the examination of the efficiency of an innovative strengthening technique of reinforced concrete (RC) columns and BCJs is presented and commented on. Two real-scale RC BCJ subassemblages were constructed for this investigation. The columns and the joint panel of the second subassemblage were externally strengthened with carbon fiber-reinforced polymer (C-FRP) ropes. To examine the efficiency of this strengthening technique we used the following transducers: (a) PZT sensors on the ropes and the concrete; (b) tSring linear variable displacement transducers (SLVDTs), diagonally installed on the BCJ, to measure the shear deformations of the BCJ panel; (c) Strain gauges on the internal steel bars. From the experimental results, it became apparent that the PZT transducers successfully diagnosed the loading step at which the primary damage occurred in the first BCJ subassemblage and the damage state of the strengthened BCJ during the loading procedure. Further, data acquired from the diagonal SLVDTs and the strain gauges provided insight into the damage state of the two tested specimens at each step of the loading procedure and confirmed the diagnosis provided by the PZT transducers. Furthermore, data acquired by the PZT transducers, SLVDTs and strain gauges proved the effectiveness of the applied strengthening technique with C-FRP ropes externally mounted on the column and the conjunction area of the examined BCJ subassemblages.
The effectiveness of externally applied fiber-reinforced polymer (FRP) ropes made of carbon fibers in X-shape formation and in both sides of the joint area of reinforced concrete (RC) beam–column connections is experimentally investigated. Six full-scale exterior RC beam–column joint specimens are tested under reverse cyclic deformation. Three of them have been strengthened using carbon FRP (CFRP) ropes that have been placed diagonally in the joint as additional, near surface-mounted reinforcements against shear. Full hysteretic curves, maximum applied load capacity, damage modes, stiffness and energy dissipation values per each loading step are presented and compared. Test results indicated that joint sub assemblages with X-shaped CFRP ropes exhibited improved hysteretic behavior and ameliorated performance with respect to the reference specimens. The effectiveness and the easy-to-apply character of the presented strengthening technique is also discussed.
Buried pipes are extensively used for oil transportation from offshore platforms. Under unfavorable loading combinations, the pipe’s uplift resistance may be exceeded, which may result in excessive deformations and significant disruptions. This paper presents findings from a series of small-scale tests performed on pipes buried in geogrid-reinforced sands, with the measured peak uplift resistance being used to calibrate advanced numerical models employing neural networks. Multilayer perceptron (MLP) and Radial Basis Function (RBF) primary structure types have been used to train two neural network models, which were then further developed using bagging and boosting ensemble techniques. Correlation coefficients in excess of 0.954 between the measured and predicted peak uplift resistance have been achieved. The results show that the design of pipelines can be significantly improved using the proposed novel, reliable and robust soft computing models.
The use of the innovative material of Carbon Fiber-Reinforced (C-FRP) ropes as external near surface mounted reinforcement for the strengthening of reinforced concrete beam-column joints is studied. The ropes are diagonally applied forming external X-type reinforcements on both sides of the joint body. The efficiency of the technique is mainly based on the assumption that the confinement of the joint body due to the applied X-shaped ropes and the contribution of the ropes as shear reinforcement are efficient enough to reduce the shear deformations observed in the joint core during the seismic excitation. Thereof the experimental measurements of the shear deformations of nine full scale beam-column joints tested in cyclic deformations are elaborated and presented herein. The specimens are sorted in two groups. Specimens of group A have been designed in the way that damage is mainly expected in the beam. On the other hand, in order to investigate the efficacy of the use of the ropes for substandard joints the group B specimens have been designed in the way that cracks and some damages are expected to develop in the joint body. Systematic and extended comparative presentations for specimens with and without ropes proved in all the examined cases that the externally mounted C-FRP ropes kept the joint body intact and substantially reduced the shear deformations especially in high drifts. Moreover, the influence of the externally mounted X-shaped C-FRP ropes on the seismic behaviour of these specimens is also examined in terms of the developing principal tensile stresses inside the joint body. From the comparisons of the principal stresses developing in specimens with and without X-form C-FRP ropes it became quite obvious that the ropes kept the joint body intact and allowed the development of higher values of principal stresses comparing with the stresses developing in specimens without ropes.
Due to insufficient transverse reinforcement, the retrofitting of beam–column joints (BCJs) in existing reinforced concrete (RC) frame structures is commonly required to alter their brittle behavior. The construction industry has extensively embraced carbon-fiber-reinforced polymers (C-FRPs) as near-surface-mounted (NSM) reinforcement. Monitoring the performance of C-FRP retrofitting is crucial due to the wide range of factors influencing its effectiveness. A novel methodology has been implemented to assess the efficacy of the C-FRP retrofitting method in this study. This approach was validated through experimental investigation of full-scale BCJs, which were retrofitted with C-FRP ropes and subjected to cyclic loading. Furthermore, piezoelectric lead zirconate titanate (PZT) patches were placed on the NSM C-FRP ropes, and the electro-mechanical impedance (EMI) method was employed to monitor the retrofitting technique’s performance. A combination of the commonly used statistical damage index root mean squared deviation (RMSD) and a hierarchical clustering-based approach (HCA) was used to assess the performance of the C-FRP retrofitting technique. The experimental investigation results strongly indicate the proposed approach’s positive impact on the reliable assessment of C-FRP retrofitting performance. Thus, the proposed approach enhances the safety and resilience of retrofitted BCJs in RC structures.