Anitha .H

Dr. Anitha .H


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2011 in Journal of Medical Systems
Verified
Journal Article
Closed access
PDF file
A.Anitha .H
Anitha .H
GPG. K. Prabhu
G. K. Prabhu

1 December 2016 in Digital Investigation
Verified
Journal Article
Closed access
ARAkshatha K R
Akshatha K R
KKKarunakar A K
Karunakar A K
A.Anitha .H
Anitha .H
RURaghavendra U.
Raghavendra U.
DSDinesh Shetty
Dinesh Shetty

1 November 2020 in Pattern Recognition Letters
Verified
Journal Article
Closed access
PPPooja Prabhu
Pooja Prabhu
AKA.K. Karunakar
A.K. Karunakar
A.Anitha .H
Anitha .H
NPN. Pradhan
N. Pradhan

1 June 2014 in Biomedical Engineering Letters
Verified
Journal Article
Closed access
PDF file
A.Anitha .H
Anitha .H
KKKarunakar A K
Karunakar A K
KDK. V. N. Dinesh
K. V. N. Dinesh

14 August 2023 in Brain Sciences
Verified
Journal Article
Open access
PDF file
ULUtkarsh Lal
Utkarsh Lal
SMSuhas M.V
Suhas M.V
A.Anitha .H
Anitha .H
Accurate sleep stage detection is crucial for diagnosing sleep disorders and tailoring treatment plans. Polysomnography (PSG) is considered the gold standard for sleep assessment since it captures a diverse set of physiological signals. While various studies have employed complex neural networks for sleep staging using PSG, our research emphasises the efficacy of a simpler and more efficient architecture. We aimed to integrate a diverse set of feature extraction measures with straightforward machine learning, potentially offering a more efficient avenue for sleep staging. We also aimed to conduct a comprehensive comparative analysis of feature extraction measures, including the power spectral density, Higuchi fractal dimension, singular value decomposition entropy, permutation entropy, and detrended fluctuation analysis, coupled with several machine-learning models, including XGBoost, Extra Trees, Random Forest, and LightGBM. Furthermore, data augmentation methods like the Synthetic Minority Oversampling Technique were also employed to rectify the inherent class imbalance in sleep data. The subsequent results highlighted that the XGBoost classifier, when used with a combination of all feature extraction measures as an ensemble, achieved the highest performance, with accuracies of 87%, 90%, 93%, 96%, and 97% and average F1-scores of 84.6%, 89%, 90.33%, 93.5%, and 93.5% for distinguishing between five-stage, four-stage, three-stage, and two distinct two-stage sleep configurations, respectively. This combined feature extraction technique represents a novel addition to the body of research since it achieves higher performance than many recently developed deep neural networks by utilising simpler machine-learning models.

6 July 2022 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
RNRoshan Ramakrishna Naik
Roshan Ramakrishna Naik
A.Anitha .H
Anitha .H
SBShyamasunder N Bhat
Shyamasunder N Bhat
NANishanth Ampar
Nishanth Ampar
RKRaghuraj Kundangar
Raghuraj Kundangar
Pedicle screw insertion is considered a complex surgery among Orthopaedics surgeons. Exclusively to prevent postoperative complications associated with pedicle screw insertion, various types of image intensity registration-based navigation systems have been developed. These systems are computation-intensive, have a small capture range and have local maxima issues. On the other hand, deep learning-based techniques lack registration generalizability and have data dependency. To overcome these limitations, a patient-specific hybrid 3D-2D registration principled framework was designed to map a pedicle screw trajectory between intraoperative X-ray image and preoperative CT image. An anatomical landmark-based 3D-2D Iterative Control Point (ICP) registration was performed to register a pedicular marker pose between the X-ray images and axial preoperative CT images. The registration framework was clinically validated by generating projection images possessing an optimal match with intraoperative X-ray images at the corresponding control point registration. The effectiveness of the registered trajectory was evaluated in terms of displacement and directional errors after reprojecting its position on 2D radiographic planes. The mean Euclidean distances for the Head and Tail end of the reprojected trajectory from the actual trajectory in the AP and lateral planes were shown to be 0.6–0.8 mm and 0.5–1.6 mm, respectively. Similarly, the corresponding mean directional errors were found to be 4.90 and 20. The mean trajectory length difference between the actual and registered trajectory was shown to be 2.67 mm. The approximate time required in the intraoperative environment to axially map the marker position for a single vertebra was found to be 3 min. Utilizing the markerless registration techniques, the designed framework functions like a screw navigation tool, and assures the quality of surgery being performed by limiting the need of postoperative CT.