Raghuraj Kundangar

Raghuraj Kundangar

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2022 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
RNRoshan Ramakrishna Naik
Roshan Ramakrishna Naik
A.Anitha .H
Anitha .H
SBShyamasunder N Bhat
Shyamasunder N Bhat
NANishanth Ampar
Nishanth Ampar
RKRaghuraj Kundangar
Raghuraj Kundangar
Pedicle screw insertion is considered a complex surgery among Orthopaedics surgeons. Exclusively to prevent postoperative complications associated with pedicle screw insertion, various types of image intensity registration-based navigation systems have been developed. These systems are computation-intensive, have a small capture range and have local maxima issues. On the other hand, deep learning-based techniques lack registration generalizability and have data dependency. To overcome these limitations, a patient-specific hybrid 3D-2D registration principled framework was designed to map a pedicle screw trajectory between intraoperative X-ray image and preoperative CT image. An anatomical landmark-based 3D-2D Iterative Control Point (ICP) registration was performed to register a pedicular marker pose between the X-ray images and axial preoperative CT images. The registration framework was clinically validated by generating projection images possessing an optimal match with intraoperative X-ray images at the corresponding control point registration. The effectiveness of the registered trajectory was evaluated in terms of displacement and directional errors after reprojecting its position on 2D radiographic planes. The mean Euclidean distances for the Head and Tail end of the reprojected trajectory from the actual trajectory in the AP and lateral planes were shown to be 0.6–0.8 mm and 0.5–1.6 mm, respectively. Similarly, the corresponding mean directional errors were found to be 4.90 and 20. The mean trajectory length difference between the actual and registered trajectory was shown to be 2.67 mm. The approximate time required in the intraoperative environment to axially map the marker position for a single vertebra was found to be 3 min. Utilizing the markerless registration techniques, the designed framework functions like a screw navigation tool, and assures the quality of surgery being performed by limiting the need of postoperative CT.

5 December 2018 in MUSCULOSKELETAL SURGERY
Verified
Journal Article
Closed access
PDF file
RKRaghuraj Kundangar
Raghuraj Kundangar
SMS. P. Mohanty
S. P. Mohanty
SBShyamasunder N Bhat
Shyamasunder N Bhat

10 June 2022 in Medical & Biological Engineering & Computing
Verified
Journal Article
Open access
PDF file
RNRoshan Ramakrishna Naik
Roshan Ramakrishna Naik
A.Anitha .H
Anitha .H
SBShyamasunder N Bhat
Shyamasunder N Bhat
NANishanth Ampar
Nishanth Ampar
RKRaghuraj Kundangar
Raghuraj Kundangar
Spine surgeries are vulnerable to wrong-level surgeries and postoperative complications because of their complex structure. Unavailability of the 3D intraoperative imaging device, low-contrast intraoperative X-ray images, variable clinical and patient conditions, manual analyses, lack of skilled technicians, and human errors increase the chances of wrong-site or wrong-level surgeries. State of the art work refers 3D-2D image registration systems and other medical image processing techniques to address the complications associated with spine surgeries. Intensity-based 3D-2D image registration systems had been widely practiced across various clinical applications. However, these frameworks are limited to specific clinical conditions such as anatomy, dimension of image correspondence, and imaging modalities. Moreover, there are certain prerequisites for these frameworks to function in clinical application, such as dataset requirement, speed of computation, requirement of high-end system configuration, limited capture range, and multiple local maxima. A simple and effective registration framework was designed with a study objective of vertebral level identification and its pose estimation from intraoperative fluoroscopic images by combining intensity-based and iterative control point (ICP)–based 3D-2D registration. A hierarchical multi-stage registration framework was designed that comprises coarse and finer registration. The coarse registration was performed in two stages, i.e., intensity similarity-based spatial localization and source-to-detector localization based on the intervertebral distance correspondence between vertebral centroids in projected and intraoperative X-ray images. Finally, to speed up target localization in the intraoperative application, based on 3D-2D vertebral centroid correspondence, a rigid ICP-based finer registration was performed. The mean projection distance error (mPDE) measurement and visual similarity between projection image at finer registration point and intraoperative X-ray image and surgeons’ feedback were held accountable for the quality assurance of the designed registration framework. The average mPDE after peak signal to noise ratio (PSNR)–based coarse registration was 20.41mm. After the coarse registration in spatial region and source to detector direction, the average mPDE reduced to 12.18mm. On finer ICP-based registration, the mean mPDE was finally reduced to 0.36 mm. The approximate mean time required for the coarse registration, finer registration, and DRR image generation at the final registration point were 10 s, 15 s, and 1.5 min, respectively. The designed registration framework can act as a supporting tool for vertebral level localization and its pose estimation in an intraoperative environment. The framework was designed with the future perspective of intraoperative target localization and its pose estimation irrespective of the target anatomy. Graphical


1 January 2024 in Gazi Medical Journal
Verified
Journal Article
Closed access
KUKeerthan Ranga Nayak U
Keerthan Ranga Nayak U
SBShyamasunder N Bhat
Shyamasunder N Bhat
NANishanth Ampar
Nishanth Ampar
RKRaghuraj Kundangar
Raghuraj Kundangar

15 April 2021 in BMJ Case Reports
Verified
Journal Article
Open access
PDF file
NHNikhil Hegde
Nikhil Hegde
RKRaghuraj Kundangar
Raghuraj Kundangar
ANAmpar Nishanth
Ampar Nishanth
SBShyamasunder N Bhat
Shyamasunder N Bhat