A Fresnel lens is an optical component that can be used to create systems more compact, cost-effective, and lightweight than those using conventional continuous surface optics. However, Fresnel lenses can usually cause a loss of flux efficiency and non-uniform distribution of illuminance due to secondary refraction by surface discontinuities, especially along the groove facet. We therefore proposed to modify a groove angle in the Fresnel lens and analyzed interrelation between the groove angle and multiple optical performances, such as flux efficiency and the uniformity of illuminance and color. The groove angle was optimized to maximize the uniformity and efficiency in the target viewing angle considering various weights of merit functions. Specifically, in our study, when the uniformity of illuminance had a little more weight than the flux efficiency (ratio of 0.6:0.4), final optimum groove angles of 24.7°, 29.4°, and 31.3° were obtained at target viewing angles of 20°, 30°, and 40°, respectively. We also fabricated a modified Fresnel lens with a groove angle of 29.4° using UV-imprinting. The real optical performance of the fabricated Fresnel lens was then compared to that of a spherical lens.
Osteoporosis is the most common bone disorder, which is a highly dangerous condition that can promote bone metastases. As the current treatment for osteoporosis involves long-term medication therapy and a cure for bone metastasis is not known, ongoing efforts are required for drug development for osteoporosis. Animal experiments, traditionally used for drug development, raise ethical concerns and are expensive and time-consuming. Organ-on-a-chip technology is being developed as a tool to supplement such animal models. In this study, we developed a bone-on-a-chip by co-culturing osteoblasts, osteocytes, and osteoclasts in an extracellular matrix environment that can represent normal bone, osteopenia, and osteoporotic conditions. We then simulated bone metastases using breast cancer cells in three different bone conditions and observed that bone metastases were most active in osteoporotic conditions. Furthermore, it was revealed that the promotion of bone metastasis in osteoporotic conditions is due to increased vascular permeability. The bone-on-a-chip developed in this study can serve as a platform to complement animal models for drug development for osteoporosis and bone metastasis.
In this study, a design methodology for a multi-optical probe confocal imaging system was developed. To develop an imaging system that has the required resolving power and imaging area, this study focused on a design methodology to create a scalable and easy-to-implement confocal imaging system. This system overcomes the limitations of the optical complexities of conventional multi-optical probe confocal imaging systems and the short working distance using a micro-objective lens module composed of two microlens arrays and a telecentric relay optical system. The micro-objective lens module was fabricated on a glass substrate using backside alignment photolithography and thermal reflow processes. To test the feasibility of the developed methodology, an optical system with a resolution of 1 μm/pixel using multi-optical probes with an array size of 10 × 10 was designed and constructed. The developed system provides a 1 mm × 1 mm field of view and a sample scanning range of 100 μm. The optical resolution was evaluated by conducting sample tests using a knife-edge detecting method. The measured lateral resolution of the system was 0.98 μm.
An all-glass bifurcation microfluidic chip for blood plasma separation was fabricated by a cost-effective glass molding process using an amorphous carbon (AC) mold, which in turn was fabricated by the carbonization of a replicated furan precursor. To compensate for the shrinkage during AC mold fabrication, an enlarged photoresist pattern master was designed, and an AC mold with a dimensional error of 2.9% was achieved; the dimensional error of the master pattern was 1.6%. In the glass molding process, a glass microchannel plate with negligible shape errors (~1.5%) compared to AC mold was replicated. Finally, an all-glass bifurcation microfluidic chip was realized by micro drilling and thermal fusion bonding processes. A separation efficiency of 74% was obtained using the fabricated all-glass bifurcation microfluidic chip.
1 May 2022 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy