Jun Jiang

Prof. Jun Jiang

Wenzhou Medical University, Wenzhou, Zhejiang, China
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2024 in Ophthalmology
Verified
Journal Article
Closed access
BSBinbin Su
Binbin Su
PCPauline Cho
Pauline Cho
SVStephen J. Vincent
Stephen J. Vincent
JCJiaojie Chen
Jiaojie Chen
CYCong Ye
Cong Ye
JJJun Jiang
Jun Jiang

2 December 2021 in Eye and Vision
Verified
Journal Article
Open access
PDF file
XLXinting Liu
Xinting Liu
ZLZhiyi Lin
Zhiyi Lin
FWFeifu Wang
Feifu Wang
XPXiaoyi Peng
Xiaoyi Peng
WHWenwen He
Wenwen He
JJJun Jiang
Jun Jiang
Background: This study aims to examine interocular differences in the choroidal thickness and vascular density of the choriocapillaris in anisometropic myopes and to further explore the relationship between choroidal blood flow and myopia. Methods: The sample comprised 44 participants with anisometropic myopia, aged 9 to 18 years, with normal best-corrected visual acuity. All participants underwent a series of examinations, including spherical equivalent refraction (SER) and axial length (AL), measured by a Lenstar optical biometer and optical coherence tomography angiography (OCTA) scanner. OCT measured the choroidal thickness, vascular density, and flow voids of the choriocapillaris, and a customized algorithm was implemented in MATLAB R2017a with the post-correction of AL. The choroidal thickness was measured at the fovea and 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 mm nasally, temporally, inferiorly, and superiorly to the fovea. The vascular density and the flow voids of the choriocapillaris were measured at a 0.6-mm-diameter central circle, and the 0.6–2.5 mm diameter circle in the nasal, temporal, inferior, and superior regions. Repeated-measured ANOVAs were used to analyze the interocular differences. Partial correlations with the K value and age adjustments were used to study the relationships between the choroidal thickness, the choriocapillaris vascular density and flow voids, the SER and AL. Results: The choroidal thickness of the more myopic eyes was significantly thinner than less myopic eyes (P ≤ 0.001), and the flow voids in the more myopic eyes were more than less myopic eyes (P = 0.002). There was no significant difference in the vascular density of the choriocapillaris between the more and less myopic eyes (P = 0.525). However, when anisometropia was more than 1.50 D, the vascular density of choriocapillaris in the more myopic eyes was significantly less than the less myopic eyes (P = 0.026). The interocular difference of the choroidal thickness was significantly correlated with the interocular difference in SER and AL in the center, superior, and inferior regions but not in the nasal or temporal regions. The interocular differences of the vascular density and the flow voids of the choriocapillaris were not correlated with the interocular difference of SER and AL. Conclusions: The choroidal thickness is thinner in the more myopic eyes. The flow void is increased, and the vascular density of the choriocapillaris is reduced in the more myopic eyes of children with anisometropia exceeding 1.50 D.

6 June 2023 in Eye and Vision
Verified
Journal Article
Open access
PDF file
HWHao Wu
Hao Wu
TPTianli Peng
Tianli Peng
WZWeihe Zhou
Weihe Zhou
ZHZihan Huang
Zihan Huang
HLHongyu Li
Hongyu Li
JJJun Jiang
Jun Jiang
Background: Despite receiving orthokeratology (ortho-k), the efficacy of retarding ocular elongation during myopia varies among myopic children. The current study aimed to investigate the early changes of choroidal vasculature at one month after ortho-k treatment and its association with one-year ocular elongation, as well as the role of such choroidal responses in predicting the one-year control efficacy of ortho-k treatment. Methods: A prospective cohort study was conducted in myopic children treated with ortho-k. Myopic children aged between 8 and 12 years who were willing to wear ortho-k lenses were recruited consecutively from the Eye Hospital of Wenzhou Medical University. Subfoveal choroidal thickness (SFCT), submacular total choroidal luminal area (LA), stromal area (SA), choroidal vascularity index (CVI), choriocapillaris flow deficit (CcFD) were evaluated by optical coherence tomography (OCT) and OCT angiography over a one-year period. Results: Fifty eyes from 50 participants (24 males) who finished one-year follow-ups as scheduled were included, with a mean age of 10.31 ± 1.45 years. The one-year ocular elongation was 0.19 ± 0.17 mm. The LA (0.03 ± 0.07 mm2), SA (0.02 ± 0.05 mm2) increased proportionally after one-month of ortho-k wear (both P < 0.01), as did the SFCT (10.62 ± 19.98 μm, P < 0.001). Multivariable linear regression analyses showed that baseline CVI (β = − 0.023 mm/1%, 95% CI: − 0.036 to − 0.010), one-month LA change (β = − 0.009 mm/0.01 mm2, 95% CI: − 0.014 to − 0.003), one-month SFCT change (β = − 0.035 mm/10 µm, 95% CI: − 0.053 to − 0.017) were independently associated with one-year ocular elongation during ortho-k treatment after adjusting with age and sex (all P < 0.01). The area under the receiver operating characteristic curve of prediction model including baseline CVI, one-month SFCT change, age, and sex achieved 0.872 (95% CI: 0.771 to 0.973) for discriminating children with slow or fast ocular elongation. Conclusions: Choroidal vasculature is associated with ocular elongation during ortho-k treatment. Ortho-k treatment induces increases in choroidal vascularity and choroidal thickness as early as one month. Such early changes can act as predictive biomarkers of myopia control efficacy over a long term. The utilization of these biomarkers may help clinicians identify children who can benefit from ortho-k treatment, and thus has critical implications for the management strategies towards myopia control.

15 March 2018 in Eye and Vision
Verified
Journal Article
Open access
PDF file
JCJiaojie Chen
Jiaojie Chen
WHWei Huang
Wei Huang
RZRong Zhu
Rong Zhu
JJJun Jiang
Jun Jiang
YLYiyu Li
Yiyu Li
This retrospective study was designed to investigate the sole influence of orthokeratology (OK) lens fitting decentration on the Zernike coefficients of the reshaped anterior corneal surface. This study comprised a review of 106 right eyes and measurements of corneal topography both before OK and at 1-month follow-up visit. A routine was designed to calculate local corneal surface astigmatism and assist the determination of OK lens fitting decentration from pupil center. The pupil-centered corneal Zernike coefficients of baseline (PCCB) and post-treatment (PCCP) were calculated. Meanwhile, the OK-lens-centered corneal Zernike coefficients of post-treatment (OCCP) were also calculated and considered as the presumptive ideal fitting group without decentration. Relationships between lens fitting decentration and the change of Zernike coefficients including (PCCP − PCCB) and (PCCP − OCCP) were analyzed. Patients with a mean age of 11 ± 2.36 years old had an average spherical equivalent refractive error of −3.52 ± 1.06 D before OK. One month after treatment, OK lens fitting decentration from pupil center was 0.68 ± 0.35 mm. RMS of 3rd-order (P < 0.05), RMS of 4th-order (P < 0.001) and RMS of total high order (P < 0.001) corneal Zernike coefficients were increased in PCCP by comparing with OCCP, which was solely caused by lens fitting decentration. Nevertheless, no significant difference was observed in $$ {C}_2^0 $$ (P > 0.05). For the high order corneal Zernike coefficients in (PCCP – OCCP), radial distance of decentration was correlated with $$ {C}_3^{-1} $$ (r = −0.296, P < 0.05), $$ {C}_3^1 $$ (r = −0.396, P < 0.001), and $$ {C}_4^0 $$ (r = 0.449, P < 0.001), horizontal decentration was significantly correlated with $$ {C}_3^1 $$ (r = 0.901, P < 0.001) and $$ {C}_5^1 $$ (r = 0.340, P < 0.001), and vertical decentration was significantly correlated with $$ {C}_3^{-1} $$ (r = 0.904, P < 0.001). OK lens fitting decentration within 1.5 mm hardly influenced the change of corneal spherical power for myopia correction, but significantly induced additional corneal high order Zernike coefficients including $$ {C}_3^{-1} $$ , $$ {C}_3^1 $$ , $$ {C}_4^0 $$ , and $$ {C}_5^1 $$ .

21 August 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
FJFeng Jiang
Feng Jiang
ZCZheyi Chen
Zheyi Chen
HBHua Bi
Hua Bi
EEEdgar Ekure
Edgar Ekure
BSBinbin Su
Binbin Su
JJJun Jiang
Jun Jiang
To investigate the association between ocular sensory dominance and interocular refractive error difference (IRED). A total of 219 subjects were recruited. The refractive errors were determined by objective refraction with a fixation target located 6 meters away. 176 subjects were myopic, with 83 being anisometropic (IRED ≥ 0.75 D). 43 subjects were hyperopic, with 22 being anisometropic. Sensory dominance was measured with a continuous flashing technique with the tested eye viewing a Gabor increasing in contrast and the fellow eye viewing a Mondrian noise decreasing in contrast. The log ratio of Mondrian to Gabor’s contrasts was recorded when a subject just detected the tilting direction of the Gabor during each trial. T-test was used to compare the 50 values collected from each eye, and the t-value was used as a subject’s ocular dominance index (ODI) to quantify the degree of ocular dominance. A subject with ODI ≥ 2 (p < 0.05) had clear dominance and the eye with larger mean ratio was the dominant one. Otherwise, a subject had an unclear dominance. The anisometropic subjects had stronger ocular dominance in comparison to non-anisometropic subjects (rank-sum test, p < 0.01 for both myopic and hyperopic subjects). In anisometropic subjects with clear dominance, the amplitude of the anisometropia was correlated with ODI values (R = 0.42, p < 0.01 in myopic anisometropic subjects; R = 0.62, p < 0.01 in hyperopic anisometropic subjects). Moreover, the dominant eyes were more myopic in myopic anisometropic subjects (sign-test, p < 0.05) and less hyperopic in hyperopic anisometropic subjects (sign-test, p < 0.05). The degree of ocular sensory dominance is associated with interocular refractive error difference.

18 July 2022 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
LLLei Lei
Lei Lei
YHYuhan Hu
Yuhan Hu
HSHui Shi
Hui Shi
ZBZhishu Bao
Zhishu Bao
YWYiping Wu
Yiping Wu
XLXing yi Li
Xing yi Li
Poly(ethylene glycol) (PEG)-based hydrogels as highly promising 3D cell scaffolds have been widely implemented in the field of tissue regrowth and regeneration, yet the functionalized PEG hydrogel providing dynamic, cell-instructive microenvironments is inherently difficult to obtain. Here, we have exploited the specificity of click reaction to develop a set of hydrogels based on 4-arm PEG tetraazide (4-arm-PEG-N3) and di-propargylated peptides (GRGDG and GRDGG) with tunable physicochemical properties applicable for 3D cell scaffolds. The azide groups of PEG were reacted with the alkynyl groups of peptides, catalyzed by copper to form triazole rings, thus generating a cross-linked hydrogel. The gelation time and mechanical strength of the hydrogels varied according to the PEG/peptide feed ratio. The resulting hydrogel exhibited a typical porous microstructure and suitable swelling behavior. The in vitro cytotoxicity test indicated that the resulting hydrogels did not cause apparent cytotoxicity against human corneal epithelial cells (HCECs). After co-incubation with HCECs, the density of RGD as well as peptide sequence in the hydrogels remarkably affected the cell attachment, spreadability, and proliferation. Additionally, the proposed hydrogel showed high ocular biocompatibility after being embedded subconjunctivally into rabbit eyes. Overall, these findings highlighted that the biofunctional hydrogels formed by PEG and RGD motifs via a controllable click reaction might be promising 3D cell scaffolds for corneal epithelial regeneration.