Yiyu Li

Dr. Yiyu Li


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2018 in Eye and Vision
Verified
Journal Article
Open access
PDF file
JCJiaojie Chen
Jiaojie Chen
WHWei Huang
Wei Huang
RZRong Zhu
Rong Zhu
JJJun Jiang
Jun Jiang
YLYiyu Li
Yiyu Li
This retrospective study was designed to investigate the sole influence of orthokeratology (OK) lens fitting decentration on the Zernike coefficients of the reshaped anterior corneal surface. This study comprised a review of 106 right eyes and measurements of corneal topography both before OK and at 1-month follow-up visit. A routine was designed to calculate local corneal surface astigmatism and assist the determination of OK lens fitting decentration from pupil center. The pupil-centered corneal Zernike coefficients of baseline (PCCB) and post-treatment (PCCP) were calculated. Meanwhile, the OK-lens-centered corneal Zernike coefficients of post-treatment (OCCP) were also calculated and considered as the presumptive ideal fitting group without decentration. Relationships between lens fitting decentration and the change of Zernike coefficients including (PCCP − PCCB) and (PCCP − OCCP) were analyzed. Patients with a mean age of 11 ± 2.36 years old had an average spherical equivalent refractive error of −3.52 ± 1.06 D before OK. One month after treatment, OK lens fitting decentration from pupil center was 0.68 ± 0.35 mm. RMS of 3rd-order (P < 0.05), RMS of 4th-order (P < 0.001) and RMS of total high order (P < 0.001) corneal Zernike coefficients were increased in PCCP by comparing with OCCP, which was solely caused by lens fitting decentration. Nevertheless, no significant difference was observed in $$ {C}_2^0 $$ (P > 0.05). For the high order corneal Zernike coefficients in (PCCP – OCCP), radial distance of decentration was correlated with $$ {C}_3^{-1} $$ (r = −0.296, P < 0.05), $$ {C}_3^1 $$ (r = −0.396, P < 0.001), and $$ {C}_4^0 $$ (r = 0.449, P < 0.001), horizontal decentration was significantly correlated with $$ {C}_3^1 $$ (r = 0.901, P < 0.001) and $$ {C}_5^1 $$ (r = 0.340, P < 0.001), and vertical decentration was significantly correlated with $$ {C}_3^{-1} $$ (r = 0.904, P < 0.001). OK lens fitting decentration within 1.5 mm hardly influenced the change of corneal spherical power for myopia correction, but significantly induced additional corneal high order Zernike coefficients including $$ {C}_3^{-1} $$ , $$ {C}_3^1 $$ , $$ {C}_4^0 $$ , and $$ {C}_5^1 $$ .

21 June 2022 in Frontiers in Medicine
Verified
Journal Article
Open access
RCRuru Chen
Ruru Chen
HLHengli Lian
Hengli Lian
CMColm McAlinden
Colm McAlinden
ESEirini Skiadaresi
Eirini Skiadaresi
SLSiyu Liu
Siyu Liu
YLYiyu Li
Yiyu Li
Objective: To establish a normative database for the vascular density (VD) in macular, disc, and peripapillary regions in healthy myopic children and to evaluate associated ocular features with optical coherence tomography angiography (OCTA).Methods: This was an observational, prospective and cross-sectional study. 776 Chinese healthy myopic children (375 boys and 401 girls) were enrolled, mean (±SD) age 9.84 ± 1.98 (range 6–16) years. En-face angiogram OCTA was performed on 6 mm × 6 mm retinal and 4.5 mm × 4.5 mm disc regions. VD measurements in the macular retina were segmented into the four regions: superficial capillary plexus (SCP), intermediate capillary plexus (ICP), deep capillary plexus (DCP), and choriocapillaris (CC). Correlations between macular, disc, and peripapillary VD and possible influencing factors [age, gender, axial length (AL), spherical equivalent refraction (SER), right/left eye, and signal strength index (SSI)] were assessed by Pearson’s correlation and multivariate regression analysis.Results: For macular scans, the corrected VD in the ICP region was (48.25 ± 4.24)% for the whole macular retina. The macular ICP VD in most sections was lower than the SCP, DCP, and CC (all P < 0.001). The corrected VD in CC was (72.96 ± 4.42)% for the whole macular retina. The macular CC VD in every section was all higher than the SCP, ICP, and DCP (all P < 0.001). The size of foveal avascular zone (FAZ) and foveal VD 300 (FD-300) was 0.28 mm2± 0.10 mm2 and (58.43 ± 4.17)% respectively. For disc scans, the corrected VD was (58.04 ± 2.73)% for the whole disc area. Both AL and SER were strongly correlated with ICP, DCP, and CC VD in all regions (all P < 0.01). Larger SSI was correlated with a lower VD in the SCP and ICP, and a higher VD in DCP and CC (all P < 0.01).Conclusion: Vascular density values provide large scale normative data on macular, disc, and peripapillary vascular parameters in a large sample of healthy myopic children with OCTA measured in the four different retinal plexuses and regions. The VD in different regions had various influencing factors; mainly a close correlation with AL and SSI.

1 January 2018 in Chinese Optics Letters
Verified
Journal Article
Closed access
YLYiyu Li
Yiyu Li
WHWei Huang Wei Huang
Wei Huang Wei Huang
HFHaihua Feng Haihua Feng
Haihua Feng Haihua Feng
JCJiaojie Chen Jiaojie Chen
Jiaojie Chen Jiaojie Chen
Astigmatism is inevitable and inherent to progressive addition lenses (PALs), which are typically distributed in the lateral areas on both sides of the progressive corridor. In this study, we took into account the spectacle frame for the customized freeform PAL design with the variational-difference numerical approach. The PAL surface with minimized astigmatism, approximately equal to 84% of the added power, was numerically resolved without expending the zone for clear vision. We validated our approach by experimentally demonstrating the procedure from tool path generation to surface power measurement, thus providing an efficient solution to the personalization of astigmatism-minimized PAL design and manufacture.

26 January 2025 in Photonics
Verified
Journal Article
Open access
PDF file
HJHuilv Jiang
Huilv Jiang
ZWZhao zeng Wei
Zhao zeng Wei
QYQuan Yuan
Quan Yuan
YLYiqian Li
Yiqian Li
KMKe Ma
Ke Ma
YLYiyu Li
Yiyu Li
Using micro-structure components in spectacle lenses has enabled myopia progression control in children and teenagers. However, the optical design of these spectacle lenses has never been discussed, leading to a lack of correct understanding of the underlying optical treatment principles. In this work, array-patterned hexagonal lenslets with two powers of opposite signs were proposed to construct a lenslet array-integrated (LARI) spectacle lens developed for an ongoing, randomized, controlled clinical trial and to support the optical approach to myopia control leveraging retinal image blur. We found that the phase modulation induced by the micro-structures of the lenslet array contributes to the increase in RMS wavefront aberrations, leading to image blur, further inspiring the novel array-patterned micro-structure design with high-order phase elements (HOPEs). The optical performance of both LARI and HOPE spectacle lenses was investigated by simulation and experiment.

23 January 2019 in OSA Continuum
Verified
Journal Article
Open access
PDF file
YLYiyu Li
Yiyu Li
RZRong Zhu
Rong Zhu
WHWei Huang
Wei Huang
HCHao Chen
Hao Chen
We propose a ray-mapping based algorithm for the tissue ablation calculation to produce an optimum freeform anterior corneal surface that is responsible for the correction of ocular aberrations. With knowledge of the measured ocular wavefront and the anterior corneal surface, the numerical ray tracing method is used to calculate the intra-corneal wavefront and to generate the optimal corneal ablation profile determined by the accurate ray-mapping between the intra-corneal wavefront and the target ocular wavefront. This method is compared with the conventional wavefront-guided based algorithm for the ametropic eye models in theory, providing superior performance both in the aberration-free correction and the aberration selective correction.

25 May 2026 in Ophthalmology Science
Verified
Journal Article
Open access
BMBangXun Mao
BangXun Mao
CHChangChang He
ChangChang He
QYQian Ye
Qian Ye
WLWeiJia Liu
WeiJia Liu
YLYiQian Li
YiQian Li
FBFangjun Bao
Fangjun Bao
To compare regional biomechanical and topographic outcomes between transepithelial (Epi-on) and epithelium-off (Epi-off) continuous accelerated corneal cross-linking (ACXL) in keratoconus. A retrospective cohort study. Seventy-seven keratoconic eyes were included: 45 with Epi-on ACXL and 32 with Epi-off ACXL. All eyes underwent ACXL (10 mW/cm2, 7.2 J/cm2). Pentacam HR and Corvis ST measurements were obtained preoperatively (pre), and at 1 month (pos1m), and 6 months (pos6m) postoperatively. The SSIv2m, M, and J0, J45 were evaluated across central (0–3 mm), paracentral (3–6 mm), and peripheral (6–9 mm) regions. Correlated measurements were analyzed using generalized estimating equations for regional and longitudinal data, and generalized linear models for intergroup comparisons, with both absolute (Δ) and relative changes (Δ%) evaluated. Regional changes in SSIv2m, M, J0, and J45 were analyzed across central (0–3 mm), paracentral (3–6 mm), and peripheral (6–9 mm) regions preoperatively and at 1 and 6 months postoperatively. At 6 months, SSIv2m increased significantly in all regions of the Epi-off ACXL group (greatest centrally), whereas the Epi-on group showed no consistent change. ΔSSIv2m between preoperative and pos6m was significantly greater in Epi-off ACXL than Epi-on ACXL across all regions (central: P < 0.01; paracentral and peripheral: P < 0.05). Central flattening (negative ΔM) was significant in the Epi-off ACXL group (P < 0.001) and exceeded that in Epi-on ACXL (P < 0.001). No significant changes were detected in J0 or J45. Δ%SSIv2m exceeded Δ%M in the paracentral and peripheral (paracentral: P < 0.01; peripheral: P < 0.05) regions after Epi-off ACXL. Epi-off ACXL induces stronger and more durable biomechanical stiffening and central flattening than Epi-on ACXL. Biomechanical parameters, particularly SSIv2, were more sensitive than curvature-based metrics for detecting regional treatment effects. Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.