Representative Publications

View All Publications
22 March 2022 in Prosthetics and Orthotics International
Verified
Journal Article
Closed access
CNCalvin C Ngan
Calvin C Ngan
HSHarry Sivasambu
Harry Sivasambu
KKKerri Kelland
Kerri Kelland
SRSandra Ramdial
Sandra Ramdial
JAJan Andrysek
Jan Andrysek
Background: The implementation of digital technology (DT) in orthotics and prosthetics (O&P) has been slow despite recent research suggesting that the use of DT will continue to grow and become more prevalent within the industry. There is a need to further investigate DT in O&P practice and the current state of its use in the field. Objective: This study aimed to explore the views and experiences of practitioners using DT workflows in their O&P practice. Methods: In this qualitative descriptive study, 10 in-depth, semistructured interviews with O&P practitioners were conducted. A content analysis was performed to analyze the transcripts and identify key themes from the data. Results: The study examined the experiences of practitioners using or trying to use DT in their practices, and three key themes were identified on the implementation of digital practice: 1) technological advancement and scientific evidence; 2) marketplace, economic, and operational factors; and 3) industry mindset shift in embracing DT practice. Conclusion: A collaborative effort involving academia, healthcare institutions, vendors, and individual practitioners will be required to facilitate the widespread adoption of DT in O&P. More work is required to overcome challenges from the technical, logistical, and cultural aspects.

1 January 2022 in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
Verified
Journal Article
Open access
PDF file
AMAlexandria Michelini
Alexandria Michelini
HSHarry Sivasambu
Harry Sivasambu
JAJan Andrysek
Jan Andrysek
BACKGROUND: Biofeedback (BFB), the practice of providing real-time sensory feedback has been shown to improve gait rehabilitation outcomes. BFB training through rhythmic stimulation has the potential to improve spatiotemporal gait asymmetries while minimizing cognitive load by encouraging a synchronization between the user’s gait cycle and an external rhythm. OBJECTIVE: The purpose of this work was to evaluate if rhythmic stimulation can improve the stance time symmetry ratio (STSR) and to compare vibrotactile to auditory stimulation. Gait parameters including velocity, cadence, stride length, double support time, and step length symmetry, were also examined. METHODOLOGY: An experimental rhythmic stimulation system was developed, and twelve healthy adults (5 males), age 28.42 ± 10.93 years, were recruited to participate in walking trials. A unilateral ankle weight was used to induce a gait asymmetry to simulate asymmetry as commonly exhibited by individuals with lower limb amputation and other clinical disorders. Four conditions were evaluated: 1) No ankle weight baseline, 2) ankle weight without rhythmic stimulation, 3) ankle weight + rhythmic vibrotactile stimulation (RVS) using alternating motors and 4) ankle weight + rhythmic auditory stimulation (RAS) using a single-tone metronome at the participant’s self-selected cadence. FINDINGS: As expected the STSR became significantly more asymmetrical with the ankle weight (i.e. induced asymmetry condition). STSR improved significantly with RVS and RAS when compared to the ankle weight without rhythmic stimulation. Cadence also significantly improved with RVS and RAS compared to ankle weight without rhythmic stimulation. With the exception of double support time, the other gait parameters were unchanged from the ankle weight condition. There were no statistically significant differences between RVS and RAS. CONCLUSION: This study found that rhythmic stimulation can improve the STSR when an asymmetry is induced. Moreover, RVS is at least as effective as auditory stimulation in improving STSR in healthy adults with an induced gait asymmetry. Future work should be extended to populations with mobility impairments and outside of laboratory settings. Layman's Abstract Providing feedback to users in real-time has been shown to improve walking in many populations with gait deviations. Feedback in the form of rhythmic stimulation involves consistent cues to which the user matches their movement. This work compared the effects of sound-based (RAS) and vibration-based (RVS) stimulation systems on the walking symmetry of healthy adults. A simple stimulation system was used with twelve healthy adults in walking trials. The walking trials included some in which the participant wore an ankle weight on a single leg to create a non-symmetrical walking pattern. Four different conditions were tested: No ankle weight, with an ankle weight, with an ankle weight and RAS, and with an ankle weight and RVS. Walking symmetry improved with both RVS and RAS compared to ankle weight only. Walking speed, cadence, and step length did not change. These findings show that RVS is at least as effective as RAS and may be a useful technique for gait rehabilitation. Future work should involve clinical populations and in real-world settings. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/36223/29090 How To Cite: Michelini A., Sivasambu H., Andrysek J. The short-term effects of rhythmic vibrotactile and auditory biofeedback on the gait of individuals after weight-induced asymmetry. Canadian Prosthetics & Orthotics Journal. 2022; Volume 5, Issue 1, No.6. https://doi.org/10.33137/cpoj.v5i1.36223 Corresponding Author: Jan Andrysek, PhDBloorview Research Institute, Holland Bloorview Kids Rehabilitation Hospital, Toronto, Canada.,E-Mail: jandrysek@hollandbloorview.ca ORCID ID: https://orcid.org/0000-0002-4976-1228

10 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
CNCalvin C Ngan
Calvin C Ngan
HSHarry Sivasambu
Harry Sivasambu
SRSandra Ramdial
Sandra Ramdial
JAJan Andrysek
Jan Andrysek
Advancements in digital imaging technologies hold the potential to transform prosthetic and orthotic practices. Non-contact optical scanners can capture the shape of the residual limb quickly, accurately, and reliably. However, their suitability in clinical practice, particularly for the transradial (below-elbow) residual limb, is unknown. This project aimed to evaluate the reliability of an optical scanner-based shape capture process for transradial residual limbs related to volumetric measurements and shape assessment in a clinical setting. A dedicated setup for digitally shape capturing transradial residual limbs was developed, addressing challenges with scanning of small residual limb size and aspects such as positioning and patient movement. Two observers performed three measurements each on 15 participants with transradial-level limb absence. Overall, the developed shape capture process was found to be highly repeatable, with excellent intra- and inter-rater reliability that was comparable to the scanning of residual limb cast models. Future work in this area should compare the differences between residual limb shapes captured through digital and manual methods.

23 October 2021 in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
Verified
Journal Article
Open access
PDF file
RNRafael Escamilla Nunez
Rafael Escamilla Nunez
HSHarry Sivasambu
Harry Sivasambu
JAJan Andrysek
Jan Andrysek
BACKGROUND: Gait symmetry is the degree of equality of biomechanical parameters between limbs within a gait cycle. Human gait is highly symmetrical; however, in the presence of pathology, gait often lacks symmetry. Biofeedback (BFB) systems have demonstrated the potential to reduce gait asymmetry, improve gait function, and benefit overall long-term musculoskeletal health. OBJECTIVE(S): The aim of this study was to develop a BFB system and evaluate three unique BFB strategies, including bidirectional control – constant vibration (BC), bidirectional control – variable vibration (BV), and unidirectional control – variable vibration (UV) relevant to gait symmetry. The assessed feedback strategies were a combination of vibration frequency/amplitude levels, vibration thresholds, and vibrotactile stimuli from one and two vibrating motors (tactors). Learning effect and short-term retention were also assessed. METHODOLOGY: Testing was performed using a custom BFB system that induces stance time asymmetries to modulate temporal gait symmetry. The BFB system continuously monitors specific gait events (heel-strike and toe-off) and calculates the symmetry ratio, based on the stance time of both limbs to provide real-time biomechanical information via the vibrating motors. Overall walking performance of ten (n=10) able-bodied individuals (age 24.8 ± 4.4 years) was assessed via metrics of symmetry ratio, symmetry ratio error, walking speed, and motor's vibration percentages. FINDINGS: All participants utilized BFB somatosensory information to modulate their symmetry ratio. UV feedback produced a greater change in symmetry ratio, and it came closer to the targeted symmetry ratio. Learning or short-term retention effects were minimal. Walking speeds were reduced with feedback compared to no feedback; however, UV walking speeds were significantly faster compared to BV and BC. CONCLUSION: The outcomes of this study provide new insights into the development and implementation of feedback strategies for gait retraining BFB systems that may ultimately benefit individuals with pathological gait. Future work should assess longer-term use and long-term learning and retention effects of BFB systems in the populations of interest. Layman's Abstract Healthy walking is usually highly symmetrical with the same movements occurring on both sides of the body. However, certain disorders can cause abnormal and asymmetrical walking movements. Biofeedback can improve the movements during walking. This study used a custom biofeedback system to test three ways of applying biofeedback including having one and two motors that vibrated in unique ways. The biofeedback system was set up to guide participants to change their normal walking pattern to be less symmetrical. Walking movements of ten young able-bodied individuals were measured while walking with the biofeedback system. The results showed a change in walking symmetry for all participants. Using a single vibrating motor resulted in the greatest changes in walking symmetry. The changes in walking symmetry occurred only when using biofeedback, and walking patterns quickly returned to normal when the biofeedback was turned off. Overall, all feedback methods caused the users to walk slower than their typical walking speed. These findings provide important new information about the changes in walking caused by different biofeedback methods. Future work should evaluate long-term effects of biofeedback methods in the populations of interest. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/36744/28677 How To Cite: Escamilla-Nunez R, Sivasambu H, Andrysek J. Exploration of vibrotactile biofeedback strategies to induce stance time asymmetries. Canadian Prosthetics & Orthotics Journal. 2022; Volume 5, Issue 1, No.2. https://doi.org/10.33137/cpoj.v5i1.36744 Corresponding Author: Rafael Escamilla-Nunez,
Institute of Biomedical Engineering, University of Toronto, Toronto, Canada. E-Mail: rafael.escamilla@mail.utoronto.ca ORCID ID: https://orcid.org/0000-0002-2739-878X

4 January 2021 in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
Verified
Journal Article
Open access
PDF file
MHMegan Hamilton
Megan Hamilton
HSHarry Sivasambu
Harry Sivasambu
Kamran BehdinanKamran Behdinan
Kamran Behdinan
JAJan Andrysek
Jan Andrysek
BACKGROUND: Pressure sensing at the body-device interface can help assess the quality of fit and function of assistive devices during physical activities and movement such as walking and running. However, the dynamic performance of various pressure sensor configurations is not well established. OBJECTIVE(S): Two common commercially available thin-film pressure sensors were tested to determine the effects of clinically relevant setup configurations focusing on loading areas, interfacing elements (i.e. ‘puck’) and calibration methods. METHODOLOGY: Testing was performed using a customized universal testing machine to simulate dynamic, mobility relevant loads at the body-device interface. Sensor performance was evaluated by analyzing accuracy and hysteresis. FINDINGS: The results suggest that sensor calibration method has a significant effect on sensor performance although the difference is mitigated by using an elastomeric loading puck. Both sensors exhibited similar performance during dynamic testing that agree with accuracy and hysteresis values reported by manufacturers and in previous studies assessing mainly static and quasi-static conditions. CONCLUSION: These findings suggest that sensor performance under mobility relevant conditions may be adequately represented via static and quasi-testing testing. This is important since static testing is much easier to apply and reduces the burden on users to verify dynamic performance of sensors prior to clinical application. The authors also recommend using a load puck for dynamic testing conditions to achieve optimal performance. Layman's Abstract Pressure sensors can be used in prosthetics to provide clinicians with data about how well a device fits and functions. However, pressure sensors are unproven when it comes to use during activities such as walking or running. This study tested two common pressure sensors in a setup that applied forces similar to walking. These findings indicate that sensor calibration affects sensor accuracy. Accuracy can be improved by applying a small puck to the sensor to spread the load more evenly. With the puck, the performance of the sensors was found to be acceptable for potential use in clinical applications. These findings also show that dynamic testing of pressure sensors may not be needed prior to clinical usage. Instead, performance can be based on static testing which is easier to do. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/36059/27891 How To Cite: Hamilton M, Sivasambu H, Behdinan K, Andrysek J. Evaluating the dynamic performance of interfacial pressure sensors at a simulated body-device interface. Canadian Prosthetics & Orthotics Journal. 2021;Volume 4, Issue 1, No.4. https://doi.org/10.33137/cpoj.v4i1.36059 Corresponding Author: Jan Andrysek, PhD, Bloorview Research Institute, Holland Bloorview Kids Rehabilitation Hospital, Toronto, Canada. Email: jandrysek@hollandbloorview.ca ORCID: https://orcid.org/0000-0002-4976-1228