Individuals with lower-limb amputation often have gait deficits and diminished mobility function. Biofeedback systems have the potential to improve gait rehabilitation outcomes. Research on biofeedback has steadily increased in recent decades, representing the growing interest toward this topic. This systematic review highlights the methodological designs, main technical and clinical challenges, and evidence relating to the effectiveness of biofeedback systems for gait rehabilitation. This review provides insights for developing an effective, robust, and user-friendly wearable biofeedback system. The literature search was conducted on six databases and 31 full-text articles were included in this review. Most studies found biofeedback to be effective in improving gait. Biofeedback was most commonly concurrently provided and related to limb loading and symmetry ratios for stance or step time. Visual feedback was the most used modality, followed by auditory and haptic. Biofeedback must not be obtrusive and ideally provide a level of enjoyment to the user. Biofeedback appears to be most effective during the early stages of rehabilitation but presents some usability challenges when applied to the elderly. More research is needed on younger populations and higher amputation levels, understanding retention as well as the relationship between training intensity and performance.

2 June 2023 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
RNRafael Escamilla Nunez
Rafael Escamilla Nunez
AGA. Gouda
A. Gouda
JAJan Andrysek
Jan Andrysek
Individuals with lower-limb amputation (LLA) often exhibit atypical gait patterns and asymmetries. These patterns can be corrected using biofeedback (BFB). Real-time BFB strategies have demonstrated to be effective to various degrees in BFB systems. However, no studies have evaluated the use of corrective vibrotactile BFB strategies to improve temporal gait symmetry of LLA. The aim of this study was to evaluate a wearable vibrotactile BFB system to improve stance time symmetry ratio (STSR) of LLA, and compare two corrective BFB strategies that activate either one or two vibrating motors at two different frequency and amplitude levels, based on a pre-set STSR target. Gait patterns of five unilateral LLA were assessed with and without BFB. Spatiotemporal and kinematic gait parameters were measured and assessed using a wearable motion capture system. Usability and workload were assessed using the System Usability Scale and NASA Task Load Index questionnaires, respectively. Results showed that participants significantly (p<0.001) improved STSR with BFB; however, this coincided with a reduction in gait speed and cadence compared to walking without feedback. Knee and hip flexion angles improved and changes in other parameters were variable. Immediate post-test retention effects were observed, suggesting that gait changes due to BFB were preserved for at least a short-time after feedback was withdrawn. System usability was found to be acceptable while using BFB. The outcomes of this study provide new insights into the development and implementation of clinically practical and viable BFB systems. Future work should focus on assessing the long-term use and retention effects of BFB outside controlled-laboratory conditions.

23 October 2021 in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
Verified
Journal Article
Open access
PDF file
RNRafael Escamilla Nunez
Rafael Escamilla Nunez
HSHarry Sivasambu
Harry Sivasambu
JAJan Andrysek
Jan Andrysek
BACKGROUND: Gait symmetry is the degree of equality of biomechanical parameters between limbs within a gait cycle. Human gait is highly symmetrical; however, in the presence of pathology, gait often lacks symmetry. Biofeedback (BFB) systems have demonstrated the potential to reduce gait asymmetry, improve gait function, and benefit overall long-term musculoskeletal health. OBJECTIVE(S): The aim of this study was to develop a BFB system and evaluate three unique BFB strategies, including bidirectional control – constant vibration (BC), bidirectional control – variable vibration (BV), and unidirectional control – variable vibration (UV) relevant to gait symmetry. The assessed feedback strategies were a combination of vibration frequency/amplitude levels, vibration thresholds, and vibrotactile stimuli from one and two vibrating motors (tactors). Learning effect and short-term retention were also assessed. METHODOLOGY: Testing was performed using a custom BFB system that induces stance time asymmetries to modulate temporal gait symmetry. The BFB system continuously monitors specific gait events (heel-strike and toe-off) and calculates the symmetry ratio, based on the stance time of both limbs to provide real-time biomechanical information via the vibrating motors. Overall walking performance of ten (n=10) able-bodied individuals (age 24.8 ± 4.4 years) was assessed via metrics of symmetry ratio, symmetry ratio error, walking speed, and motor's vibration percentages. FINDINGS: All participants utilized BFB somatosensory information to modulate their symmetry ratio. UV feedback produced a greater change in symmetry ratio, and it came closer to the targeted symmetry ratio. Learning or short-term retention effects were minimal. Walking speeds were reduced with feedback compared to no feedback; however, UV walking speeds were significantly faster compared to BV and BC. CONCLUSION: The outcomes of this study provide new insights into the development and implementation of feedback strategies for gait retraining BFB systems that may ultimately benefit individuals with pathological gait. Future work should assess longer-term use and long-term learning and retention effects of BFB systems in the populations of interest. Layman's Abstract Healthy walking is usually highly symmetrical with the same movements occurring on both sides of the body. However, certain disorders can cause abnormal and asymmetrical walking movements. Biofeedback can improve the movements during walking. This study used a custom biofeedback system to test three ways of applying biofeedback including having one and two motors that vibrated in unique ways. The biofeedback system was set up to guide participants to change their normal walking pattern to be less symmetrical. Walking movements of ten young able-bodied individuals were measured while walking with the biofeedback system. The results showed a change in walking symmetry for all participants. Using a single vibrating motor resulted in the greatest changes in walking symmetry. The changes in walking symmetry occurred only when using biofeedback, and walking patterns quickly returned to normal when the biofeedback was turned off. Overall, all feedback methods caused the users to walk slower than their typical walking speed. These findings provide important new information about the changes in walking caused by different biofeedback methods. Future work should evaluate long-term effects of biofeedback methods in the populations of interest. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/36744/28677 How To Cite: Escamilla-Nunez R, Sivasambu H, Andrysek J. Exploration of vibrotactile biofeedback strategies to induce stance time asymmetries. Canadian Prosthetics & Orthotics Journal. 2022; Volume 5, Issue 1, No.2. https://doi.org/10.33137/cpoj.v5i1.36744 Corresponding Author: Rafael Escamilla-Nunez,