Zhenyu Xiong

Dr. Zhenyu Xiong

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2017 in Progress in Neuro-Psychopharmacology and Biological Psychiatry
Verified
Journal Article
Closed access
YCYu-Chen Chen
Yu-Chen Chen
FBFan Bo
Fan Bo
WXWenqing Xia
Wenqing Xia
SLShenghua Liu
Shenghua Liu
PWPeng Wang
Peng Wang
XYXindao Yin
Xindao Yin

1 November 2020 in Brachytherapy
Verified
Journal Article
Closed access
TCTsuicheng Chiu
Tsuicheng Chiu
ZXZhenyu Xiong
Zhenyu Xiong
DPDavid Donald Mortimer Parsons
David Donald Mortimer Parsons
MFMichael R. Folkert
Michael R. Folkert
PMPaul M. Medin
Paul M. Medin
BHBrian Hrycushko
Brian Hrycushko

30 October 2019 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
YZYuncheng Zhong
Yuncheng Zhong
WLWeiguo Lu
Weiguo Lu
MCMingli Chen
Mingli Chen
ZXZhenyu Xiong
Zhenyu Xiong
XCXinyi Cheng
Xinyi Cheng
YSYiping Shao
Yiping Shao
Online positron emission tomography (PET) image-based method uses an initial particle beam to measure the particle beam range (BR) within the same fraction so that any measured range-shift with respect to the predicted BR can be compensated before the rest therapeutic beam deliveries. However, the method requires to use a low-dose initial beam to minimize the risk of beam overshooting, which leads to low image count and inaccurate BR measurement. In this in-silico study, we evaluate the feasibility of a new online PET imaging method that measures BR at the mid-plane of a target volume with part of the high-dose therapy beams to verify BR and guide adaptive treatment replanning. Simulations included various processes of proton beam radiations to a tumor inside a human-brain phantom, positron, and PET image generation at the mid-plane with initial beams, activity range measurement, and range-shift compensated beam delivery. The results demonstrated that the new method, under the simulated conditions, can achieve ~1.1-mm mid-plane BR measurement accuracy and closely match the delivered range-shift compensated dose distribution with the planned one. Overall, it is promising that this new method may significantly improve the particle therapy accuracy.

21 April 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
LJLiang Jiang
Liang Jiang
LZLeilei Zhou
Leilei Zhou
ZAZhongping Ai
Zhongping Ai
CXChaoyong Xiao
Chaoyong Xiao
WLWen Liu
Wen Liu
YCYu-Chen Chen
Yu-Chen Chen
Glioma grading plays an important role in surgical resection. We investigated the ability of different feature reduction methods in support vector machine (SVM)-based diffusion kurtosis imaging (DKI) histogram parameters to distinguish glioma grades. A total of 161 glioma patients who underwent magnetic resonance imaging (MRI) from January 2017 to January 2020 were included retrospectively. The patients were divided into low-grade (n = 61) and high-grade (n = 100) groups. Parametric DKI maps were derived, and 45 features from the DKI maps were extracted semi-automatically for analysis. Three feature selection methods [principal component analysis (PCA), recursive feature elimination (RFE) and least absolute shrinkage and selection operator (LASSO)] were used to establish the glioma grading model with an SVM classifier. To evaluate the performance of SVM models, the receiver operating characteristic (ROC) curves of SVM models for distinguishing glioma grades were compared with those of conventional statistical methods. The conventional ROC analysis showed that mean diffusivity (MD) variance, MD skewness and mean kurtosis (MK) C50 could effectively distinguish glioma grades, particularly MD variance. The highest classification distinguishing AUC was found using LASSO at 0.904 ± 0.069. In comparison, classification AUC by PCA was 0.866 ± 0.061, and 0.899 ± 0.079 by RFE. The SVM-PCA model with the lowest AUC among the SVM models was significantly better than the conventional ROC analysis (z = 1.947, p = 0.013). These findings demonstrate the superiority of DKI histogram parameters by LASSO analysis and SVM for distinguishing glioma grades.

8 December 2022 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
PDF file
ZXZhenyu Xiong
Zhenyu Xiong
YZYuncheng Zhong
Yuncheng Zhong
TBThomas I. Banks
Thomas I. Banks
RRRobert Reynolds
Robert Reynolds
TCTsuicheng Chiu
Tsuicheng Chiu
SSStrahinja Stojadinovic
Strahinja Stojadinovic
Objectives. The purpose of this study is to present data from the clinical commissioning of an Xstrahl 150 x-ray unit used for superficial radiotherapy, Methods. Commissioning tasks included vendor acceptance tests, timer reproducibility, linearity and end-effect measurements, half-value layer (HVL) measurements, inverse square law verification, head-leakage measurements, and beam output calibration. In addition, percent depth dose (PDD) curves were determined for different combinations of filter/kV settings and applicators. Automated PDD water phantom scans were performed utilizing four contemporary detectors: a microDiamond detector, a microSilicon detector, an EDGE detector, and a PinPoint ionization chamber. The measured PDD data were compared to the published values in BJR Supplement 25, Results. The x-ray unit’s mechanical, safety, and radiation characteristics were within vendor-stated specifications. Across sixty commissioned x-ray beams, the PDDs determined in water using solid state detectors were in excellent agreement with the BJR 25 data. For the lower (<100 kVp) and medium-energy (≥100 kVp) superficial beams the average agreement was within [−3.6,+0.4]% and [−3.7,+1.4]% range, respectively. For the high-energy superficial (low-energy orthovoltage) x-rays at 150 kVp, the average difference for the largest 20 × 20 cm2 collimator was (−0.7 ± 1.0)%, Conclusions. This study presents machine characterization data collected for clinical use of a superficial x-ray unit. Special focus was placed on utilizing contemporary detectors and techniques for the relative PDD measurements using a motorized water phantom. The results in this study confirm that the aggregate values published in the BJR 25 report still serve as a valid benchmark when comparing data from site-specific measurements, or the reference data for clinical utilization without such measurements, Advances in knowledge. This paper presents comprehensive data from the acceptance and commissioning of a modern kilovoltage superficial x-ray radiotherapy machine. Comparisons between the PDD data measured in this study using different detectors and BJR 25 data are highlighted.

27 February 2026 in Cancers
Verified
Journal Article
Open access
PDF file
Xiao WangXiao Wang
Xiao Wang
YZYin Zhang
Yin Zhang
XZXinxin Zhang
Xinxin Zhang
ZXZhenyu Xiong
Zhenyu Xiong
KXKeying Xu
Keying Xu
CMChi Ma
Chi Ma
Proton FLASH radiotherapy represents a promising innovation in the treatment of abdominal cancers, offering the potential to expand the therapeutic window by delivering ultra-high dose rates (UHDR) that spare normal tissue while maintaining tumor control. This approach is particularly beneficial for gastrointestinal (GI) tumors, where radiation dose escalation is often limited by the radiosensitivity of nearby organs. This review explores recent preclinical, planning, and technical developments in proton FLASH for abdominal sites and outlines the challenges and future directions for clinical translation. We reviewed the available published literature on proton FLASH radiotherapy, with a focus on abdominal applications. Recent preclinical studies in abdominal models have shown encouraging, though inconsistent, evidence of reduced toxicity with proton FLASH. Parallel advances in treatment planning have also demonstrated technical feasibility in achieving UHDR across complex abdominal geometries. However, key challenges remain, including variability in biological responses, lack of standardized dose-rate definitions, delivery system constraints, and the absence of robust clinical data. Although only limited clinical trials are currently underway, proton FLASH may enable safer hypofractionation, reirradiation, and dose escalation strategies in the future. Its successful clinical translation will require coordinated advances in biology, physics, and technology, supported by rigorous preclinical validation and carefully designed clinical trials.