Epileptic seizure is one of the most chronic neurological diseases that instantaneously disrupts the lifestyle of affected individuals. Toward developing novel and efficient technology for epileptic seizure management, recent diagnostic approaches have focused on developing machine/deep learning model (ML/DL)-based electroencephalogram (EEG) methods. Importantly, EEG’s noninvasiveness and ability to offer repeated patterns of epileptic-related electrophysiological information have motivated the development of varied ML/DL algorithms for epileptic seizure diagnosis in the recent years. However, EEG’s low amplitude and nonstationary characteristics make it difficult for existing ML/DL models to achieve a consistent and satisfactory diagnosis outcome, especially in clinical settings, where environmental factors could hardly be avoided. Though several recent works have explored the use of EEG-based ML/DL methods and statistical feature for seizure diagnosis, it is unclear what the advantages and limitations of these works are, which might preclude the advancement of research and development in the field of epileptic seizure diagnosis and appropriate criteria for selecting ML/DL models and statistical feature extraction methods for EEG-based epileptic seizure diagnosis. Therefore, this paper attempts to bridge this research gap by conducting an extensive systematic review on the recent developments of EEG-based ML/DL technologies for epileptic seizure diagnosis. In the review, current development in seizure diagnosis, various statistical feature extraction methods, ML/DL models, their performances, limitations, and core challenges as applied in EEG-based epileptic seizure diagnosis were meticulously reviewed and compared. In addition, proper criteria for selecting appropriate and efficient feature extraction techniques and ML/DL models for epileptic seizure diagnosis were also discussed. Findings from this study will aid researchers in deciding the most efficient ML/DL models with optimal feature extraction methods to improve the performance of EEG-based epileptic seizure detection.
Swallowing is a continuous process with substantive interdependencies among different muscles, and it plays a significant role in our daily life. The aim of this study was to propose a novel technique based on high-density surface electromyography (HD sEMG) for the evaluation of normal swallowing functions. A total of 96 electrodes were placed on the front neck to acquire myoelectric signals from 12 healthy subjects while they were performing different swallowing tasks. HD sEMG energy maps were constructed based on the root mean square values to visualize muscular activities during swallowing. The effects of different volumes, viscosities, and head postures on the normal swallowing process were systemically investigated by using the energy maps. The results showed that the HD sEMG energy maps could provide detailed spatial and temporal properties of the muscle electrical activity, and visualize the muscle contractions that closely related to the swallowing function. The energy maps also showed that the swallowing time and effort was also explicitly affected by the volume and viscosity of the bolus. The concentration of the muscular activities shifted to the opposite side when the subjects turned their head to either side. The proposed method could provide an alternative method to physiologically evaluate the dynamic characteristics of normal swallowing and had the advantage of providing a full picture of how different muscle activities cooperate in time and location. The findings from this study suggested that the HD sEMG technique might be a useful tool for fast screening and objective assessment of swallowing disorders or dysphagia.
Biopotential signals are mainly characterized by low amplitude and thus often distorted by extraneous interferences, such as power line interference in the recording environment and movement artifacts during the acquisition process. With the presence of such large-amplitude interferences, subsequent processing and analysis of the acquired signals becomes quite a challenging task that has been reported by many previous studies. A number of software-based filtering techniques have been proposed, with most of them being able to minimize the interferences but at the expense of distorting the useful components of the target signal. Therefore, this study proposes a hardware-based method that utilizes a shielded drive circuit to eliminate extraneous interferences on biopotential signal recordings, while also preserving all useful components of the target signal. The performance of the proposed method was evaluated by comparing the results with conventional hardware and software filtering methods in three different biopotential signal recording experiments (electrocardiogram (ECG), electro-oculogram (EOG), and electromyography (EMG)) on an ADS1299EEG-FE platform. The results showed that the proposed method could effectively suppress power line interference as well as its harmonic components, and it could also significantly eliminate the influence of unwanted electrode lead jitter interference. Findings from this study suggest that the proposed method may provide potential insight into high quality acquisition of different biopotential signals to greatly ease subsequent processing in various biomedical applications.
20 March 2024 in IEEE Journal of Biomedical and Health Informatics
The efficient patient-independent and interpretable framework for electroencephalogram (EEG) epileptic seizure detection (ESD) has informative challenges due to the complex pattern of EEG nature. Automated detection of ES is crucial, and Explainable Artificial Intelligence (XAI) is urgently needed to justify algorithmic predictions in clinical settings. Therefore, this study implements an XAI-based computer-aided ES detection system (XAI-CAESDs), comprising three major modules including of feature engineering module, a seizure detection module, and an explainable decision-making process module in a smart healthcare system. To ensure the privacy and security of biomedical EEG data, the blockchain is employed. Initially, the Butterworth filter eliminates various artifacts, and the Dual-Tree Complex Wavelet Transform (DTCWT) decomposes EEG signals, extracting real and imaginary eigenvalue features using frequency domain (FD), time domain (TD), and Fractal Dimension (FD) of linear and non-linear features. The best features are selected by using Correlation Coefficients (CC) and Distance Correlation (DC). The selected features are fed into the Stacking Ensemble Classifiers (SEC) for EEG ES detection. Further, the Shapley Additive Explanations (SHAP) method of XAI is implemented to facilitate the interpretation of predictions made by the proposed approach, enabling medical experts to make accurate and understandable decisions. The proposed ensemble-based stacking classifiers in XAI-CAESDs have demonstrated 2% best average accuracy, Recall, specificity, and F1-score using the University of California, Irvine, Bonn University, and Boston Children's Hospital-MIT EEG data sets. The proposed framework enhances decision-making and the diagnosis process using biomedical EEG signals and ensures data security in smart healthcare systems.
Objective. Silent speech recognition (SSR) based on surface electromyography (sEMG) is an attractive non-acoustic modality of human-machine interfaces that convert the neuromuscular electrophysiological signals into computer-readable textual messages. The speaking process involves complex neuromuscular activities spanning a large area over the facial and neck muscles, thus the locations of the sEMG electrodes considerably affected the performance of the SSR system. However, most of the previous studies used only a quite limited number of electrodes that were placed empirically without prior quantitative analysis, resulting in uncertainty and unreliability of the SSR outcomes. Approach. In this study, the technique of high-density sEMG was proposed to provide a full representation of the articulatory muscle activities so that the optimal electrode configuration for SSR could be systemically explored. A total of 120 closely spaced electrodes were placed on the facial and neck muscles to collect the high-density sEMG signals for classifying ten digits (0–9) silently spoken in both English and Chinese. The sequential forward selection algorithm was adopted to explore the optimal electrodes configurations. Main Results. The results showed that the classification accuracy increased rapidly and became saturated quickly when the number of selected electrodes increased from 1 to 120. Using only ten optimal electrodes could achieve a classification accuracy of 86% for English and 94% for Chinese, whereas as many as 40 non-optimized electrodes were required to obtain comparable accuracies. Also, the optimally selected electrodes seemed to be mostly distributed on the neck instead of the facial region, and more electrodes were required for English recognition to achieve the same accuracy. Significance. The findings of this study can provide useful guidelines about electrode placement for developing a clinically feasible SSR system and implementing a promising approach of human-machine interface, especially for patients with speaking difficulties.
Objective. The neurocognitive attention functions involve the cooperation of multiple brain regions, and the defects in the cooperation will lead to attention-deficit/hyperactivity disorder (ADHD), which is one of the most common neuropsychiatric disorders for children. The current ADHD diagnosis is mainly based on a subjective evaluation that is easily biased by the experience of the clinicians and lacks the support of objective indicators. The purpose of this study is to propose a method that can effectively identify children with ADHD. Approach. In this study, we proposed a CNN-LSTM model to solve the three-class problems of classifying ADHD, attention deficit disorder (ADD) and healthy children, based on a public electroencephalogram (EEG) dataset that includes event-related potential (ERP) EEG signals of 144 children. The convolution visualization and saliency map methods were used to observe the features automatically extracted by the proposed model, which could intuitively explain how the model distinguished different groups. Main results. The results showed that our CNN-LSTM model could achieve an accuracy as high as 98.23% in a five-fold cross-validation method, which was significantly better than the current state-of-the-art CNN models. The features extracted by the proposed model were mainly located in the frontal and central areas, with significant differences in the time period mappings among the three different groups. The P300 and contingent negative variation (CNV) in the frontal lobe had the largest decrease in the healthy control (HC) group, and the ADD group had the smallest decrease. In the central area, only the HC group had a significant negative oscillation of CNV waves. Significance. The results of this study suggest that the CNN-LSTM model can effectively identify children with ADHD and its subtypes. The visualized features automatically extracted by this model could better explain the differences in the ERP response among different groups, which is more convincing than previous studies, and it could be used as more reliable neural biomarkers to help with more accurate diagnosis in the clinics.