Oluwarotimi Williams Samuel

Dr. Oluwarotimi Williams Samuel

Chinese Academy of Sciences
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2017 in Expert Systems with Applications
Verified
Journal Article
Closed access
Oluwarotimi Williams SamuelOluwarotimi Williams Samuel
Oluwarotimi Williams Samuel
GAGrace Mojisola Asogbon
Grace Mojisola Asogbon
Arun Kumar SangaiahArun Kumar Sangaiah
Arun Kumar Sangaiah
PFPeng Fang
Peng Fang
GLGuanglin Li
Guanglin Li

7 January 2017 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
XLXiangxin Li
Xiangxin Li
Oluwarotimi Williams SamuelOluwarotimi Williams Samuel
Oluwarotimi Williams Samuel
XZXu Zhang
Xu Zhang
HWHui Wang
Hui Wang
PFPeng Fang
Peng Fang
GLGuanglin Li
Guanglin Li
Most of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs. However, the residual muscles are usually limited, especially after above-elbow amputations, which would not provide enough sEMG for the control of prostheses with multiple degrees of freedom. Signal fusion is a possible approach to solve the problem of insufficient control commands, where some non-EMG signals are combined with sEMG signals to provide sufficient information for motion intension decoding. In this study, a motion-classification method that combines sEMG and electroencephalography (EEG) signals were proposed and investigated, in order to improve the control performance of upper-limb prostheses. Four transhumeral amputees without any form of neurological disease were recruited in the experiments. Five motion classes including hand-open, hand-close, wrist-pronation, wrist-supination, and no-movement were specified. During the motion performances, sEMG and EEG signals were simultaneously acquired from the skin surface and scalp of the amputees, respectively. The two types of signals were independently preprocessed and then combined as a parallel control input. Four time-domain features were extracted and fed into a classifier trained by the Linear Discriminant Analysis (LDA) algorithm for motion recognition. In addition, channel selections were performed by using the Sequential Forward Selection (SFS) algorithm to optimize the performance of the proposed method. The classification performance achieved by the fusion of sEMG and EEG signals was significantly better than that obtained by single signal source of either sEMG or EEG. An increment of more than 14% in classification accuracy was achieved when using a combination of 32-channel sEMG and 64-channel EEG. Furthermore, based on the SFS algorithm, two optimized electrode arrangements (10-channel sEMG + 10-channel EEG, 10-channel sEMG + 20-channel EEG) were obtained with classification accuracies of 84.2 and 87.0%, respectively, which were about 7.2 and 10% higher than the accuracy by using only 32-channel sEMG input. This study demonstrated the feasibility of fusing sEMG and EEG signals towards improving motion classification accuracy for above-elbow amputees, which might enhance the control performances of multifunctional myoelectric prostheses in clinical application. The study was approved by the ethics committee of Institutional Review Board of Shenzhen Institutes of Advanced Technology, and the reference number is SIAT-IRB-150515-H0077.

15 January 2019 in IEEE Access
Verified
Journal Article
Open access
Oluwarotimi Williams SamuelOluwarotimi Williams Samuel
Oluwarotimi Williams Samuel
MAMojisola Grace Asogbon
Mojisola Grace Asogbon
YGYanjuan Geng
Yanjuan Geng
AAAli H. Al-Timemy
Ali H. Al-Timemy
SPSandeep Pirbhulal
Sandeep Pirbhulal
GLGuanglin Li
Guanglin Li
Upper-limb amputation imposes significant burden on amputees thereby restricting them from fully exploring their environments during activities of daily living. The use of intelligent learning algorithm for electromyogram-pattern recognition (EMG-PR)-based control in upper-limb prostheses is considered as an important clinical option. Though the existing EMG-PR prostheses could discriminate multiple degrees of freedom (DOF) limb movements, their transition to clinically viable option is still being challenged by some confounding factors. Toward realizing a clinically viable multiple DOF prostheses, this paper first explored the principles and dynamics of the existing intelligently driven EMG-PR-based prostheses control scheme. Then, investigations on core issues including variation in muscle contraction force, electrode shift, and subject mobility affecting the existing EMG-PR prosthetic control scheme were reported. For instance, variation in muscle contraction force and subject mobility led to degradation in the performance of the EMG-PR controlled prostheses with approximately 17.00% and 8.98% error values, respectively, which are still challenging issues among others. Thus, this paper reports core issues and best practices with respect to intelligent EMG-PR controlled prosthesis, the major challenges in implementing adaptively robust control scheme and provides future research directions that may result in the clinical realization of intuitively dexterous multiple DOF EMG-PR-based prostheses in the near future.

1 April 2018 in Computers and Electrical Engineering
Verified
Journal Article
Closed access
Oluwarotimi Williams SamuelOluwarotimi Williams Samuel
Oluwarotimi Williams Samuel
HZHui Zhou
Hui Zhou
XLXiangxin Li
Xiangxin Li
HWHui Wang
Hui Wang
HZHaoshi Zhang
Haoshi Zhang
GLGuanglin Li
Guanglin Li

1 June 2019 in Future Generation Computer Systems
Verified
Journal Article
Closed access
SPSandeep Pirbhulal
Sandeep Pirbhulal
Oluwarotimi Williams SamuelOluwarotimi Williams Samuel
Oluwarotimi Williams Samuel
Wanqing WuWanqing Wu
Wanqing Wu
Arun Kumar SangaiahArun Kumar Sangaiah
Arun Kumar Sangaiah
GLGuanglin Li
Guanglin Li

17 June 2022 in Computational Intelligence and Neuroscience
Verified
Journal Article
Open access
PDF file
IAIjaz Ahmad
Ijaz Ahmad
XWXin Wang
Xin Wang
MZMingxing Zhu
Mingxing Zhu
CWCheng Wang
Cheng Wang
YPYao Pi
Yao Pi
GLGuanglin Li
Guanglin Li
Epileptic seizure is one of the most chronic neurological diseases that instantaneously disrupts the lifestyle of affected individuals. Toward developing novel and efficient technology for epileptic seizure management, recent diagnostic approaches have focused on developing machine/deep learning model (ML/DL)-based electroencephalogram (EEG) methods. Importantly, EEG’s noninvasiveness and ability to offer repeated patterns of epileptic-related electrophysiological information have motivated the development of varied ML/DL algorithms for epileptic seizure diagnosis in the recent years. However, EEG’s low amplitude and nonstationary characteristics make it difficult for existing ML/DL models to achieve a consistent and satisfactory diagnosis outcome, especially in clinical settings, where environmental factors could hardly be avoided. Though several recent works have explored the use of EEG-based ML/DL methods and statistical feature for seizure diagnosis, it is unclear what the advantages and limitations of these works are, which might preclude the advancement of research and development in the field of epileptic seizure diagnosis and appropriate criteria for selecting ML/DL models and statistical feature extraction methods for EEG-based epileptic seizure diagnosis. Therefore, this paper attempts to bridge this research gap by conducting an extensive systematic review on the recent developments of EEG-based ML/DL technologies for epileptic seizure diagnosis. In the review, current development in seizure diagnosis, various statistical feature extraction methods, ML/DL models, their performances, limitations, and core challenges as applied in EEG-based epileptic seizure diagnosis were meticulously reviewed and compared. In addition, proper criteria for selecting appropriate and efficient feature extraction techniques and ML/DL models for epileptic seizure diagnosis were also discussed. Findings from this study will aid researchers in deciding the most efficient ML/DL models with optimal feature extraction methods to improve the performance of EEG-based epileptic seizure detection.