Objectives: To compare the value of zero echo time (ZTE) and gradient echo “black bone” (BB) MRI sequences for bone assessment of the sacroiliac joint (SI) using computed tomography (CT) as the reference standard. Materials and methods: Between May 2019 and January 2021, 79 patients prospectively underwent clinically indicated 3-T MRI including ZTE and BB imaging. Additionally, all patients underwent a CT scan covering the SI joints within 12 months of the MRI examination. Two blinded readers performed bone assessment by grading each side of each SI joint qualitatively in terms of seven features (osteophytes, subchondral sclerosis, erosions, ankylosis, joint irregularity, joint widening, and gas in the SI joint) using a 4-point Likert scale (0 = no changes–3 = marked changes). Scores were compared between all three imaging modalities. Results: Interreader agreement was largely good (k values: 0.5–0.83). Except for the feature “gas in SI joint” where ZTE exhibited significantly lower scores than CT (p < 0.001), ZTE and BB showed similar performance relative to CT for all other features (p > 0.52) with inter-modality agreement being substantial to almost perfect (Krippendorff’s alpha coefficients: 0.724–0.983). When combining the data from all features except for gas in the SI joint and when binarizing grading scores, combined sensitivity/specificity was 76.7%/98.6% for ZTE and 80.8%/99.1% for BB, respectively, compared to CT. Conclusions: The performance of ZTE and BB sequences was comparable to CT for bone assessment of the SI joint. These sequences may potentially serve as an alternative to CT yet without involving exposure to ionizing radiation.
We evaluate the preoperative visualization of the inferior alveolar nerve (IAN) and lingual nerve (LN) as reported using radiation-free magnetic resonance imaging (MRI). An accurate visualization shall minimize the postoperative risk for nerve injuries in oral and maxillofacial surgery. PubMed MEDLINE, EMBASE, Biosis, and Cochrane databases were selected for the PICOS search strategy by two reviewers using medical subject headings (MeSH) terms. Thirty studies were included in the systematic review. Based on these studies’ findings, the use of black bone MRI sequences, especially 3D short-tau inversion recovery (STIR), provides superior soft-tissue resolution and high sensitivity in detecting pathological changes. Due to the implementation variability regarding scan parameters and the use of different magnetic field strengths, studies with well-designed protocols and a low risk of bias should be conducted to obtain stronger evidence. With improved cost and time efficiency and considering the benefit–risk ratio, MRI is a promising imaging modality that could become part of routine clinical practice in the future.
31 October 2013 in Forensic Science, Medicine and Pathology