Tim Finkenstaedt

Dr. Tim Finkenstaedt

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 December 2018 in European Radiology
Verified
Journal Article
Closed access
PDF file
UMUrs J. Muehlematter
Urs J. Muehlematter
MMManoj Mannil
Manoj Mannil
ABAnton S. Becker
Anton S. Becker
KVKerstin N. Vokinger
Kerstin N. Vokinger
TFTim Finkenstaedt
Tim Finkenstaedt
RGRoman Guggenberger
Roman Guggenberger

30 June 2022 in Skeletal Radiology
Verified
Journal Article
Open access
PDF file
LWLucas Wolharn
Lucas Wolharn
RGRoman Guggenberger
Roman Guggenberger
KHKai Higashigaito
Kai Higashigaito
TSThomas Sartoretti
Thomas Sartoretti
SWSebastian Winklhofer
Sebastian Winklhofer
TFTim Finkenstaedt
Tim Finkenstaedt
Objectives: To compare the value of zero echo time (ZTE) and gradient echo “black bone” (BB) MRI sequences for bone assessment of the sacroiliac joint (SI) using computed tomography (CT) as the reference standard. Materials and methods: Between May 2019 and January 2021, 79 patients prospectively underwent clinically indicated 3-T MRI including ZTE and BB imaging. Additionally, all patients underwent a CT scan covering the SI joints within 12 months of the MRI examination. Two blinded readers performed bone assessment by grading each side of each SI joint qualitatively in terms of seven features (osteophytes, subchondral sclerosis, erosions, ankylosis, joint irregularity, joint widening, and gas in the SI joint) using a 4-point Likert scale (0 = no changes–3 = marked changes). Scores were compared between all three imaging modalities. Results: Interreader agreement was largely good (k values: 0.5–0.83). Except for the feature “gas in SI joint” where ZTE exhibited significantly lower scores than CT (p < 0.001), ZTE and BB showed similar performance relative to CT for all other features (p > 0.52) with inter-modality agreement being substantial to almost perfect (Krippendorff’s alpha coefficients: 0.724–0.983). When combining the data from all features except for gas in the SI joint and when binarizing grading scores, combined sensitivity/specificity was 76.7%/98.6% for ZTE and 80.8%/99.1% for BB, respectively, compared to CT. Conclusions: The performance of ZTE and BB sequences was comparable to CT for bone assessment of the SI joint. These sequences may potentially serve as an alternative to CT yet without involving exposure to ionizing radiation.

1 March 2017 in Investigative Radiology
Verified
Journal Article
Closed access
DKDavid Kenkel
David Kenkel
BBBorna K. Barth
Borna K. Barth
MPMarco Piccirelli
Marco Piccirelli
LFLukas Filli
Lukas Filli
TFTim Finkenstaedt
Tim Finkenstaedt
ABAndreas Boss
Andreas Boss
Objectives: The aims of this study were to implement a protocol for simultaneous multislice (SMS) accelerated diffusion-weighted imaging (DWI) of the kidneys and to perform a systematic analysis of image quality of the data sets. Materials and Methods: Ten healthy subjects and 5 patients with renal masses underwent DWI of the kidney in this prospective institutional review board–approved study on a 3 T magnetic resonance scanner. Simultaneous multislice DWI echo-planar sequences (acceleration factors [AFs] 2 and 3) were compared with conventional echo-planar DWI as reference standard for each acquisition scheme. The following 3 acquisition schemes were applied: comparison A, with increased number of acquisitions at constant scan time; comparison B, with reduction of acquisition time; and comparison C, with increased slice resolution (constant acquisition time, increasing number of slices). Interreader reliability was analyzed by calculating the intraclass correlation coefficient (ICC). Qualitative image quality features were evaluated by 2 independent radiologists on a 5-point Likert scale. Quantification accuracy of the apparent diffusion coefficients (ADCs) and signal-to-noise ratios (SNRs) were assessed by region of interest analysis. Furthermore, lesion conspicuity in the 5 patients was assessed using a 5-point Likert scale by 2 independent radiologists. Results: Interreader agreement was substantial with an ICC of 0.68 for the overall image quality and an ICC of 0.73 for the analysis of artifacts. In comparison A, AF2 resulted in increased SNR (P < 0.05) by 21% at stable image quality scores (image quality: P = 0.76, artifacts: P = 0.21). In comparison B, applying AF2, the scan time could be reduced by 46% without significant reduction in qualitative image quality scores (P = 0.059) or SNR (P = 0.126). In comparison C, slice resolution could be improved by 28% using AF2 with stable image quality scores and SNR. In general, AF3 resulted in reduced image quality and SNR. Significantly reduced ADC values were observed for AF3 in comparison C (cortex: P = 0.003; medulla: P = 0.001) compared with the standard echo-planar imaging sequence. The conventional DWI and the SMS DWI with AF2 showed stable lesion conspicuity ([AF1/AF2]: reader 1 [1.8/1.4] and reader 2 [1.8/1.4]). The lesion conspicuity was lower using AF3 (reader 1: 2.2 and reader 2: 1.8). Conclusions: In conclusion, SMS DWI of the kidney is a potential tool to substantially reduce scan time without negative effects on SNR, ADC quantification accuracy, and image quality if an AF2 is used. Although AF3 results in even higher scan time reduction, a negative impact on image quality, SNR, ADC quantification accuracy, and lesion conspicuity must be considered.

4 November 2019 in Investigative Radiology
Verified
Journal Article
Closed access
FHFlorian A. Huber
Florian A. Huber
PSPaul Schumann
Paul Schumann
JSJochen von Spiczak
Jochen von Spiczak
MWMoritz C. Wurnig
Moritz C. Wurnig
MKMarkus Klarhöfer
Markus Klarhöfer
RGRoman Guggenberger
Roman Guggenberger
Objective: The aim of this study was to compare bone imaging between ultrashort echo-time (UTE) magnetic resonance (MR) imaging and cone-beam computed tomography (CBCT) as the reference standard in patients with medication-related osteonecrosis of the jaw (MRONJ). Materials and Methods: A 1-year retrospective, blinded, and randomized qualitative analysis of UTE MR images and CBCT from 19 patients with clinically diagnosed MRONJ was performed by 2 independent radiologists. Medication-related osteonecrosis of the jaw imaging hallmarks such as osteolysis, periosteal thickening, and medullary osteosclerosis were rated visually (0 and 1 to 3 for normal and mild to severe changes) for defined anatomic regions of the jaw. In addition, segmentation of these regions was performed on coregistered MR/CBCT images for the following quantitative comparison of signal intensity (SI) on MR and gray values (GVs) on CBCT images. Interreader/modality agreement (Cohen kappa), standard testing for significant differences of (non)parametric values, and Pearson correlation of signal intensity/GV were used for statistical analysis. Results: The anterior corpus of the mandible was most often affected by MRONJ (P < 0.001). Overall, interreader agreement of qualitative MRONJ hallmark scores was almost perfect (κ = 0.81) and without significant differences between modalities (κ = 0.81 vs 0.82, CBCT vs MR, respectively). Intermodality agreement for qualitative gradings was substantial for both readers (κ = 0.77 and 0.70). Signal intensity/GV in MRONJ-affected areas differed significantly from healthy bone (P < 0.001) as well as correlation significantly between modalities (r = −0.77; P < 0.001). Conclusions: Qualitative assessment of MRONJ with radiation-free UTE MR imaging is comparable to reference standard CBCT. Quantitative measurements of both modalities significantly distinguish diseased from normal bone with strong correlations among the quantitative values in both modalities.

1 January 2019 in Investigative Radiology
Verified
Journal Article
Closed access
TFTim Finkenstaedt
Tim Finkenstaedt
PSPalanan Siriwanarangsun
Palanan Siriwanarangsun
SASuraj Achar
Suraj Achar
MCMichael Carl
Michael Carl
SFSina Finkenstaedt
Sina Finkenstaedt
WBWon C. Bae
Won C. Bae
Objectives: The objective of this study was to compare the diagnostic performance and confidence of conventional, optimized, and ultrashort time to echo (UTE) magnetic resonance (MR) protocols for detection of simulated lumbar spondylolysis in human cadavers. In addition, we sought to demonstrate the feasibility of the UTE technique in subjects with and without spondylolysis. Materials and Methods: Four human lumbar spine specimens with 46 individual pars interarticularis were randomly left intact (n = 26) or received experimental osteotomy (n = 20) using a microsurgical saw to simulate spondylolysis. The specimens were imaged using a computed tomography (CT) scan along with 3 “Tiers” of MR protocols at 3 T: Tier 1, conventional lumbar MR protocol; Tier 2, optimized conventional protocol consisting of a sagittal oblique spoiled gradient recall echo and axial oblique T1 and short tau inversion recovery sequences; and Tier 3, a sagittal UTE MR sequence. Two blinded readers evaluated the images using a 4-point scale (1 = spondylolysis certainly absent, 2 = probably absent, 3 = probably present, 4 = certainly present) at each individual pars. For each imaging protocol, diagnostic performance (sensitivity, specificity, and area under the receiver operating characteristic curve, using the surgical osteotomy as the reference) and confidence were assessed and compared using the McNemar test. Furthermore, 2 human subjects were imaged with the conventional and UTE MR protocols to demonstrate feasibility in vivo. Results: Diagnostic performance was moderate for Tiers 1 and 2, with a moderate sensitivity (0.70 to 0.75) and high (1.00) specificity. In contrast, CT and Tier 3 UTE MR imaging had both high sensitivity (1.00) and specificity (1.00). The sensitivities of CT or Tier 3 were statistically greater than Tier 1 sensitivity (P = 0.041) and neared statistical significance when compared with Tier 2 sensitivity (P = 0.074). Area under the receiver operating characteristic curve was also significantly greater for CT and Tier 3 (each area = 1.00), compared with the areas for Tier 1 (0.89, P = 0.037) or Tier 2 (0.873, P = 0.024). Diagnostic confidences of CT or Tier 3 were much greater than other Tiers: Both Tiers 1 and 2 had a large percentage of uncertain (>60%, P < 0.001) or wrong interpretations (>10%, P < 0.001), unlike CT or Tier 3 (0% uncertain or wrong interpretations). Preliminary in vivo UTE images clearly depicted intact and fractured pars. Conclusions: Our study demonstrated that the detection of pars fractures using a single sagittal UTE MR sequence is superior in performance and confidence to conventional and optimized MR protocols at 3 T, whereas matching those from CT evaluation. Furthermore, we demonstrated the feasibility of in vivo application of the UTE sequence in subjects with and without spondylolysis.

22 June 2016 in European Spine Journal
Verified
Journal Article
Closed access
PDF file
SWSebastian Winklhofer
Sebastian Winklhofer
UHUlrike Held
Ulrike Held
JBJakob M. Burgstaller
Jakob M. Burgstaller
TFTim Finkenstaedt
Tim Finkenstaedt
NBNicolae Bolog
Nicolae Bolog
FGFilippo Del Grande
Filippo Del Grande