SHADY ABDULLAH ALSHEWAIER

Dr. SHADY ABDULLAH ALSHEWAIER

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Faizan KashooFaizan Kashoo
Faizan Kashoo
RARaid Albaradie
Raid Albaradie
MAMsaad Alzhrani
Msaad Alzhrani
AAAhmad Alanazi
Ahmad Alanazi
MMMd Dilshad Manzar
Md Dilshad Manzar
ACAksh Chahal
Aksh Chahal
Background: Combining transcranial direct current stimulation (tDCS) with other therapies is reported to produce promising results in patients with stroke. The purpose of the study was to determine the effect of combining tDCS with motor imagery (MI) and upper-limb functional training for upper-limb rehabilitation among patients with chronic stroke. Methods: A single-center, prospective, randomized controlled trial was conducted among 64 patients with chronic stroke. The control group received sham tDCS with MI, while the experimental group received real tDCS with MI. Both groups performed five different upper-limb functional training exercises coupled with tDCS for 30 min, five times per week for two weeks. Fugl-Meyer’s scale (FMA) and the Action Research Arm Test (ARAT) were used to measure the outcome measures at baseline and after the completion of the 10th session. Results: Analysis of covariance showed significant improvements in the post-test mean scores for FMA (F (414.4) = 35.79, p < 0.001; η2 = 0.37) and ARAT (F (440.09) = 37.46, p < 0.001; η2 = 0.38) in the experimental group compared to the control group while controlling for baseline scores. Conclusions: Anodal tDCS stimulation over the affected primary motor cortex coupled with MI and upper-limb functional training reduces impairment and disability of the upper limbs among patients with chronic stroke.
1

26 August 2022 in Healthcare
Verified
Journal Article
Open access
PDF file
MAMahamed Ateef
Mahamed Ateef
MAMazen Alqahtani
Mazen Alqahtani
MAMsaad Alzhrani
Msaad Alzhrani
Abdulaziz A AlkathiryAbdulaziz A Alkathiry
Abdulaziz A Alkathiry
AAAhmad Alanazi
Ahmad Alanazi
SASHADY ABDULLAH ALSHEWAIER
SHADY ABDULLAH ALSHEWAIER
During the previous two decades, patient-reported outcome measures (PROMs) have been well tested, and the tools were validated in different languages across the globe. This systematic review aimed to identify the knee disease-specific outcome tools in Arabic and evaluate their methodological quality of psychometric properties of the most promising tools based on the COSMIN checklist and PRISMA guidelines. Articles published in English, from the inception of databases until the date of search (10 August 2022), were included. Articles without at least one psychometric property (reliability, validity, and responsiveness) evaluation, and articles other than in the English language, were excluded from the study. The key terms [“Arabic” AND “Knee” AND (“Questionnaire” OR “Scale”)] were used in three databases, i.e., PubMed, Scopus, and Web of Science (WoS) in the advanced search strategy. Key terms were either in the title or abstract for PubMed. Key words were in the topic (TS) for WoS. COSMIN (COnsensus-based Standards for the selection of health Measurement Instruments) risk of bias checklist was used to evaluate the methodological quality of psychometric properties of the Arabic knee-related outcome measures. A total of 99 articles were identified in PubMed, SCOPUS, and WoS. After passing inclusion and exclusion criteria, 20 articles describing 22 scales from five countries were included in this review. The instruments validated in the Arabic language are Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), knee injury and osteoarthritis outcome score (KOOS), knee outcome survey- activities of daily living scale (KOS-ADLS), Oxford knee score (OKS), anterior knee pain scale, osteoarthritis of knee and hip health-related quality of life (OAKHQoL) scale, Lysholm knee score (LKS), international documentation committee subjective knee form (IKDC), intermittent and constant osteoarthritis pain (ICOAP) questionnaire, Kujala patellofemoral pain scoring system (PFPSS), anterior knee pain scale (AKPS) and osteoarthritis quality of life questionnaire (OAQoL),. All were found to have good test-retest reliability (Intra Correlation Coefficient), internal consistency (Cronbach’s alpha), and construct validity (Visual Analog Scale, Short Form-12, RAND-36, etc.). Of 20 instruments available to assess self-reported knee symptoms and function, 12 were validated in the Saudi Arabian population. Among them, KOS-ADLS is the best PROM to be used in various knee conditions, followed by KOOS and WOMAC. The assessed methodological quality of evidence says that the knee Arabic PROMs are reliable instruments to evaluate knee symptoms/function.

11 November 2022 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
GNGopal Nambi
Gopal Nambi
Mshari AlghadierMshari Alghadier
Mshari Alghadier
EEElturabi Elsayed Ebrahim
Elturabi Elsayed Ebrahim
AVAnju Verma
Anju Verma
OAOsama R. Aldhafian
Osama R. Aldhafian
RURadhakrishnan Unnikrishnan
Radhakrishnan Unnikrishnan
Objective: The knowledge about the effective implementation of corticosteroid injection and extracorporeal shockwave therapy on radiological changes in chronic lateral epicondylitis is lacking. Therefore, the objective of this study is to find and compare the effects of corticosteroid injection and extracorporeal shockwave therapy on radiological changes in chronic lateral epicondylitis. Methods: A randomized, double-blinded controlled study was conducted on 60 LE participants at a university hospital. The active extracorporeal shockwave therapy group (n = 30) received a corticosteroid injection with active extracorporeal shockwave therapy one session a week for 4 weeks, and the placebo extracorporeal shockwave therapy group received a corticosteroid injection with placebo extracorporeal shockwave therapy. The primary outcome was pain intensity, measured with the visual analog scale. The other outcome measures were the percentage of injury measured by magnetic resonance imaging and ultrasound, functional disability, handgrip strength, patient perception, kinesiophobia, depression status, and quality of life. Results: The between-group difference in pain intensity at 4 weeks was 1.4 (CI 95% 0.77 to 2.02), which shows more improvement in the active group than in the placebo group. Improvements in the effects were noted after 8 weeks and at 6 months (1.8; CI 95% 1.50 to 2.09) follow-up. Similar improvements were also found in the percentage of injury, functional disability, handgrip strength, patient perception, kinesiophobia, depression status, and quality of life. Conclusion: Extracorporeal shockwave therapy has added effects on corticosteroid injection for improving pain, percentage of injury, functional disability, handgrip strength, patient perception, kinesiophobia, depression status and quality of life in people with chronic lateral epicondylitis.

25 July 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
MSMOHAMED YACIN SIKKANDAR
MOHAMED YACIN SIKKANDAR
SPSridharan Padmanabhan
Sridharan Padmanabhan
BMBobby Mohan
Bobby Mohan
IAIbrahim AlMohimeed
Ibrahim AlMohimeed
AAAhmad Alassaf
Ahmad Alassaf
SSSabarunisha Begum S
Sabarunisha Begum S
This paper presents the feasibility of automated and accurate in vivo measurements of vascular parameters using an ultrasound sensor. The continuous and non-invasive monitoring of certain parameters, such as pulse wave velocity (PWV), blood pressure (BP), arterial compliance (AC), and stiffness index (SI), is crucial for assessing cardiovascular disorders during surgeries and follow-up procedures. Traditional methods, including cuff-based or invasive catheter techniques, serve as the gold standard for measuring BP, which is then manually used to calculate AC and SI through imaging algorithms. In this context, the Continuous and Non-Invasive Vascular Stiffness and Arterial Compliance Screener (CaNVAS) is developed to provide continuous and non-invasive measurements of these parameters using an ultrasound sensor. By driving 5 MHz (ranging from 2.2 to 10 MHz) acoustic waves through the arterial walls, capturing the reflected echoes, and employing pre-processing techniques, the frequency shift is utilized to calculate PWV. It is observed that PWV measured by CaNVAS correlates exponentially with BP values obtained from the sphygmomanometer (BPMR-120), enabling the computation of instantaneous BP values. The proposed device is validated through measurements conducted on 250 subjects under pre- and post-exercise conditions, demonstrating an accuracy of 95% and an average coefficient of variation of 12.5%. This validates the reliability and precision of CaNVAS in assessing vascular parameters.

26 May 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
MSMOHAMED YACIN SIKKANDAR
MOHAMED YACIN SIKKANDAR
SPSridharan Padmanabhan
Sridharan Padmanabhan
BMBobby Mohan
Bobby Mohan
IAIbrahim AlMohimeed
Ibrahim AlMohimeed
AAAhmad Alassaf
Ahmad Alassaf
SSSabarunisha Begum S
Sabarunisha Begum S
In this paper, the feasibility of automated and accurate in vivo measurements of vascular parameters continuously and non-invasively using ultrasound sensor is presented. Vascular parameters such as pulse wave velocity (PWV), blood pressure (BP), arterial compliance (AC) and stiffness index (SI) are affluent indicators of cardiovascular disorders and needs to be monitored non-invasively and continuously during surgeries and follow-up procedures. Cuff based or invasive catheter techniques are considered as gold standard to measure BP and are fed manually to compute AC and SI which employ imaging algorithms. In this context, a Continuous and Non-Invasive Vascular Stiffness and Arterial Compliance Screener (CaNVAS) is developed to measure said parameters continuously and non-invasively using ultrasound sensor. Acoustic waves of 5 MHz (2.2 – 10 MHz) are driven through target arterial walls, reflected echoes captured, pre-processed and frequency shift is used to calculate PWV. It is observed that PWV measured using CaNVAS varies exponentially with BP values obtained from sphygmomanometer (BPMR-120) and this relationship is used to compute instantaneous values of BP. The proposed device is validated by performing measurements on 250 subjects in pre and post exercise conditions and found to have 95% accuracy and an average of 12.5% coefficient of variation.