Vanessa Alvané Gonçalves

Ms. Vanessa Alvané Gonçalves

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2023 in Water
Verified
Journal Article
Open access
PDF file
VGVanessa Alvané Gonçalves
Vanessa Alvané Gonçalves
Antonio AlbuquerqueAntonio Albuquerque
Antonio Albuquerque
PCPaulo Carvalho
Paulo Carvalho
PAPedro Gabriel Almeida
Pedro Gabriel Almeida
Victor CavaleiroVictor Cavaleiro
Victor Cavaleiro
Deposition of corpses in the ground is the most common burial practice, which can allow interactions between polluting compounds and the soil, groundwater, and surface water, which may afterwards lead to negative environmental impacts and risks to public health. The risk of cemeteries contaminating groundwater is related to their location, the quantity of clothes, metals and adornments buried, and geographical, geological, hydrogeological, and climatic factors. Using the DRASTIC index and geographical information system (GIS) tools, the potential for groundwater contamination was investigated in eight cemeteries located in the Figueira da Foz region (Portugal), which are the main anthropogenic pollution sources in the area. Aquifer vulnerability was assessed through the development of thirteen site characteristic maps, seven thematic maps, and a DRASTIC index vulnerability map, using GIS operation tools. No studies were found on the development of vulnerability maps with this method and digital tools. Cemeteries UC2, UC4, UC5, UC6, UC7, and UC8 are located within the zones susceptible to recharge, with an average recharge rate of 254 mm/year. Cemeteries UC5, UC7, and UC8 are expected to develop a greater water-holding capacity. The water table depth is more vulnerable at UC6, varying between 9.1 m and 15.2 m. However, results show only a high vulnerability associated with the UC4 cemetery with the contributions T,C > R,S > I > A > D, which should be under an environmental monitoring program. The area surrounding UC4 is characterized by a water table depth ranging between 15.2 m to 22.9 m, mainly fine-grained sands in both the vadose zone and the aquifer media, Gleyic Solonchaks at the topsoil, very unfavorable slope (0–2%), and high hydraulic conductivity (>81.5 m/day). The sensitivity analysis shows that the topography, soil media, and aquifer media weights were the most effective in the vulnerability assessment. However, the highest contributions to index variation were made by hydraulic conductivity, net recharge, and soil media. This type of approach not only makes it possible to assess the vulnerability of groundwater to contamination from cemeteries but also allows the definition of environmental monitoring plans as well as provides the entities responsible for its management and surveillance with a methodology and tools for its continuous monitoring.

9 August 2022 in Water
Verified
Journal Article
Open access
PDF file
VGVanessa Alvané Gonçalves
Vanessa Alvané Gonçalves
Antonio AlbuquerqueAntonio Albuquerque
Antonio Albuquerque
PAPedro Gabriel Almeida
Pedro Gabriel Almeida
Victor CavaleiroVictor Cavaleiro
Victor Cavaleiro
The sulphurous mineral waters of ‘Entre-os-Rios’, which is sited in NW Portugal, are famous for their long history as thermal baths dating back at least to the mid-sixteenth century. Because of the singularity of its water composition, especially the highest sulphur content, the mineral waters of ‘Entre-os-Rios’ are one of the most important sulphurous waters in Portugal. Despite these mineral waters having a protection perimeter buffer zone to avoid water contamination, there are potentially damaging installations (e.g., fuel station) in the closed protection buffer zone that, according to existing law, are not permitted within the protection perimeters, which defeats the purpose of their delineation. A vulnerability map was created using geographic information system (GIS) tools based on multi-criteria analysis, combining thematic maps and parameters of the DRASTIC index, for evaluating the risk of contamination in the protection area. The results showed that within the perimeter, there was a low risk of pollution. The alluvium-covered terrain was vulnerable to moderate contamination, but it was far from the catchment point. Areas of minimal risk corresponded to locations where the granitic massif had not been significantly weathered. The map enables information collection for a better definition of local resource structures and planning, namely, for restricted areas emplacement where some activities should not be allowed (e.g., agriculture and water prospection), given its influence on the confined granitic aquifer.

16 February 2024 in Water
Verified
Journal Article
Open access
PDF file
VGVanessa Alvané Gonçalves
Vanessa Alvané Gonçalves
Antonio AlbuquerqueAntonio Albuquerque
Antonio Albuquerque
PAPedro Gabriel Almeida
Pedro Gabriel Almeida
LFLuís Manuel Ferreira-Gomes
Luís Manuel Ferreira-Gomes
Victor CavaleiroVictor Cavaleiro
Victor Cavaleiro
The risk of aquifer contamination is determined by the interaction between the pollutant load and the vulnerability of an aquifer. Owing to the decomposition of bodies and degradation of artefacts, cemeteries may have a negative impact on groundwater quality and suitability for use due to the leaching of organic compounds (e.g., biodegradable organics, pharmaceuticals, and formaldehyde), inorganic compounds (e.g., nitrate and heavy metals), pathogenic bacteria, and viruses. Factors such as burial and soil type, rainfall amount, and groundwater depth may increase aquifer vulnerability to pollutants generated in cemeteries. The potential for groundwater contamination was investigated in two cemeteries of the Soure region in Portugal (Samuel–UC9 and Vinha da Rainha–UC10), using the classic DRASTIC model, followed by some adjustments, depending on the particularities of the locations, resulting in a Final Classification considered as Specific DRASTIC. By combining Remote Sensing (RS), Geographic Information System (GIS), and Analytical Hierarchy Process (AHP), groundwater potential zones (GWPZs) were identified, and aquifer vulnerability was assessed, which included the elaboration of thematic maps using GIS operation tools. The maps allowed for the identification of areas with different susceptibilities to contamination: from “Low” to “Very high” for the DRASTIC index and from “Very Low” to “Very high” for the Specific DRASTIC index. Although the difference between the UC9 and UC10 cemeteries is negligible, UC10 is more vulnerable because of its proximity to the community and critically important mineral water resources (such as Bicanho Medical Spa). The Specific model seems better-suited for describing vulnerability to cemeteries. Although there is limited groundwater quality data for the area, the development of vulnerability maps can identify areas that can be sensitive spots for groundwater contamination and establish procedures for pollution prevention.