Brillouin fiber laser with ultranarrow linewidth of 30 Hz is demonstrated for the first time without phase locking loop, the laser operates single longitudinal mode, while mode selection is achieved by a Fabry-Perot interferometer and a section of coreless fiber with Farday rotation mirror through optical phase conjugation, the Brillouin gain is provided by a 25-km fiber. The output linewidth is a factor of 100 reductions comparing with pump laser. Moreover, the laser exhibits an ultralow-frequency noise (<;15 Hz/Hz 1/2 at 10 Hz). The proposed laser configuration provides an ideal tool to achieve linewidth reduction of any laser from kilohertz level to subhundred hertz with lower frequency noise.
17 September 2019 in Journal of Lightwave Technology
Single photon detector (SPD) has a maximum count rate due to its dead time, which results in that the dynamic range of photon counting optical time-domain reflectometry (PC-OTDR) de-creases with the length of monitored fiber. To further improve the dynamic range of PC-OTDR, we propose and demonstrate an externally time-gated scheme. The externally time-gated scheme is realized by using a high-speed optical switch, i.e. a Mach-Zehnder interferometer, to modulate the back-propagation optical signal, and to allow that only a certain segment of the fiber under test is monitored by the SPD. The feasibility of proposed scheme is first examined with theoretical analysis and simulation; then we experimentally demonstrate it with our experimental PC-OTDR testbed operating at 850 nm wavelength. In our studies, a dynamic range of 30.0 dB is achieved in a 70 meters long PC-OTDR system with 50 ns ex-ternal gates, corresponding to an improvement of 11.0 dB in dynamic range comparing with no gating operation. Further-more, with the improved dynamic range, a successful identifica-tion of a 0.37 dB loss event is detected with 30-seconds accu-mulation, which could not be identified without gating operation. Our scheme paves an avenue for developing PC-OTDR systems with high dynamic range.
We first report a single-light-source orthogonally pumped triaxial atomic magnetometer with a double-cell structure. By using a beam splitter to equally allocate the pump beam, the proposed triaxial atomic magnetometer is responsive to magnetic fields in all three directions, and without sacrificing system sensitivity. The experimental results indicate that, the magnetometer achieves a sensitivity of 22 fT/Hz1/2 in x-direction with a 3-dB bandwidth of 22 Hz, a sensitivity of 23 fT/Hz1/2 in y-direction with a 3-dB bandwidth of 23 Hz, and a sensitivity of 21 fT/Hz1/2 in z-direction with a 3-dB bandwidth of 25 Hz. This magnetometer is useful for the applications that require the measurements of the three components of the magnetic field.
We show how dual wavelength differential detection can be used to measure fiber Bragg grating sensors using nanosecond pulses from a single DFB laser diode, by taking advantage of its dynamic chirp. This can be performed in two ways: by measuring the reflected power from two separate pulses driven by two different currents, or by taking two delayed digitized samples within a single pulse. A prototype instrument using fast digitizing and processing with an FPGA is used to characterize the chirp, from which the performance can be optimized for both measurement schemes.
We propose what we believe to be a new single-beam three-axis spin exchange relaxation free (SERF) vector atomic magnetometer scheme based on coordinate system deflection. A theoretical model for the system response under arbitrary angle deflection was established for the first time, and the system response at different angles was simulated and analyzed. The simulation results show that the system response increases in the direction of the non-sensitive axis and decreases in the direction of the sensitive axis as the deflection angle increases, and the two responses tend to be the same when the angle is deflected to 45-degrees. Experimental measurements were carried out at a deflection angle of 45-degrees and the results showed that the sensitivity of the magnetometer was 55fT/Hz1/2 in the x1-axis, 38fT/Hz1/2 in the y1-axis and 60fT/Hz1/2 in the z1-axis. This single-beam magnetometer can be used to construct a miniaturized and low-cost weak magnetic sensor, which is expected to be used for vector measurement of biomagnetism.
A cascading Brillouin random fiber laser with a dual pump (DP-CBRFL) is proposed and demonstrated. The DP-CBRFL can improve the Brillouin gain significantly to achieve an ultra-narrow linewidth (95.5 Hz) with 200 mW pump power, due to two cascading Brillouin gain fibers with an identical Brillouin frequency shift. Compared with the general Brillouin random fiber laser, the proposed random fiber laser has a more stable Brillouin gain spectrum and a lower mode density, which makes it have a lower intensity noise and frequency noise, especially in the low-frequency range. Meanwhile, it exhibits a high slope efficiency of 28% even if the pump power has reached 1.1 W due to the strong suppression ability of the high-order Stokes light.