Zinan Wu

Zinan Wu

Auto-generated profile, based on publicly available information

Zinan Wu

University of Electronic Science and Technology of China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2023 in Optics Express
Verified
Journal Article
Closed access
ZWZinan Wu
Zinan Wu
JZJialong Zhang
Jialong Zhang
MHMengyang He
Mengyang He
BRBokang Ren
Bokang Ren
ZWZilong Wang
Zilong Wang
YLYong Liu
Yong Liu
We first report a single-light-source orthogonally pumped triaxial atomic magnetometer with a double-cell structure. By using a beam splitter to equally allocate the pump beam, the proposed triaxial atomic magnetometer is responsive to magnetic fields in all three directions, and without sacrificing system sensitivity. The experimental results indicate that, the magnetometer achieves a sensitivity of 22 fT/Hz1/2 in x-direction with a 3-dB bandwidth of 22 Hz, a sensitivity of 23 fT/Hz1/2 in y-direction with a 3-dB bandwidth of 23 Hz, and a sensitivity of 21 fT/Hz1/2 in z-direction with a 3-dB bandwidth of 25 Hz. This magnetometer is useful for the applications that require the measurements of the three components of the magnetic field.

13 May 2024 in Optics Letters
Verified
Journal Article
Closed access
ZWZinan Wu
Zinan Wu
JZJialong Zhang
Jialong Zhang
CWChen Wei
Chen Wei
ZOZhonghua Ou
Zhonghua Ou
HYHuimin Yue
Huimin Yue
YLYong Liu
Yong Liu
We report a single-beam synthetic gradiometer operated in the spin-exchange-relaxation free (SERF) regime, using the structure of two separate atomic vapor cells spaced 2 cm apart. To improve the capability of the gradiometer in suppressing the common-mode magnetic field noise, we are aiming at investigating the effects of the system parameters on the gradiometer common-mode rejection ratio (CMRR). The mathematical expression for the relationship between the gradiometer CMRR and the two variables including the linewidth ratio and the pumping factor ratio is constructed for the first time, to our knowledge. This means that the CMRR can be optimized by controlling the linewidth and the pumping factor, which is easy to implement in the operation process. As a result, a CMRR of 246 is achieved and a gradiometer sensitivity of 4.5 fT/cm/Hz1/2 is also measured. This method provides a theoretical and experimental basis for the automated operation of gradiometers, and the gradiometer system performance can be tuned to a desired state by simply controlling the linewidth and the incident light intensity.