Yiming Deng

Prof. Dr. Yiming Deng

Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824, USA
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2019 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
Saptarshi MukherjeeSaptarshi Mukherjee
Saptarshi Mukherjee
LULalita Udpa
Lalita Udpa
SUSatish Udpa
Satish Udpa
EREdward Rothwell
Edward Rothwell
YDYiming Deng
Yiming Deng
Time reversal (TR) relies on the reciprocity nature of the wave equation. Waves diverging away from a source can be time reversed and back-propagated to focus back at the source. The transmitting and receiving antenna arrays utilized for TR are collectively termed as the TR mirror (TRM). TR imaging in the microwave regime has shown its promise in nondestructive inspection and target localization. This paper deals with the design of a microwave TRM for the detection of breast tumors. The first part of this paper discusses TR simulations based on a signal processing algorithm, to obtain the tumor location from the total fields. The processed time-reversed fields can be back-propagated in a numerical model to focus the wave at the tumor locations. Simulation results aid in investigating the feasibility and the robustness of the method. The second part of this paper deals with experimental studies for the breast tumor detection, using a pulsed time-domain system and the back-propagation model. The successful detection of single and multiple tumors embedded in a liquid breast tissue-based phantom is shown using the microwave system.

19 February 2021 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
GPGuanyu Piao
Guanyu Piao
JLJiaoyang LI
Jiaoyang LI
LULalita Udpa
Lalita Udpa
SUSatish Udpa
Satish Udpa
YDYiming Deng
Yiming Deng
Nondestructive testing (NDT) methods are widely used in the rail industry to detect rolling contact damage (RCD) defects to ensure railway safety. With the need of monitoring millions of miles of rail tracks more effectively and efficiently that leads to improved rail safety, reliability, and optimized assets management, the research on high-speed and high-accuracy NDT methods that can obtain high signal-to-noise ratio (SNR) and high sensitivity defect signals at higher speeds is of vital importance. Magnetic flux leakage (MFL) is one of the NDT methods used for high-speed rail inspection, which is suitable for detecting surface and subsurface RCD defects on railhead, but the measured MFL signals are distorted severely by the effect of motion-induced eddy currents (MIEC). However, the fundamental understanding of the mechanism of MIEC generation, distribution, and magnitude is lacking, and the physical interaction between MIEC and MFL measurement during high-speed rail inspection has not been well studied. This article investigates the effect of MIEC on three-axis MFL signals through 3-D finite-element method (FEM) simulations. The 3-D distributions of MIEC and 2-D image signals of MFL measurements for high-speed rail MFL inspection are presented and analyzed. The simulations are conducted with an inspection speed range of 0-62.5 mi/h, and a surface hemisphere-type defect and subsurface hole-type defect are both considered. The results show that the motion between the magnetizer and the rail will generate two types of MIEC, which in turn decreases the peak values of three-axis MFL signals from the subsurface defect and affects the MFL signals spatially, especially the base values along rail transverse and vertical directions. The effect of MIEC on the three-axis MFL signals in terms of SNR, sensitivity, and asymmetry is discussed.

20 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Zhiyuan XuZhiyuan Xu
Zhiyuan Xu
WXwang xiang
wang xiang
YDYiming Deng
Yiming Deng
This paper presents a rotating focused field eddy-current (EC) sensing technique, which leverages the advantages of magnetic field focusing and rotating magnetic field, for arbitrary orientation defects detection. The sensor consists of four identical excitation coils orthogonally arranged in an upside-down pyramid configuration and a giant magneto-resistive (GMR) detection element. The four coils are connected to form two figure-8-shaped focusing sub-probes, which are fed by two identical harmonic currents with 90 degrees phase difference. A finite element model-based study of arbitrary orientation defects detection was performed to understand the probe operational characteristics and optimize its design parameters. Probe prototyping and experimental validation were also carried out on a carbon steel plate specimen with four prefabricated surface-breaking defects. In-situ spot inspection with the probe rotating above the defect and a manual line-scan inspection were both conducted. Results showed that the probe has the capability of detecting defects with any orientations while maintaining the same sensitivity and the defect depth can be quantitatively evaluated by using the signal amplitude. Compared with the existing rotating field probes, the presented probe does not require additional excitation adjustment or data fusion. Meanwhile, due to its focusing effect, it can generate a strong rotating magnetic field at the defect location with a weak background noise, thus yielding superior signal-to-noise ratio.

11 October 2021 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
GPGuanyu Piao
Guanyu Piao
JLJiaoyang LI
Jiaoyang LI
LULalita Udpa
Lalita Udpa
JQJianliang Qian
Jianliang Qian
YDYiming Deng
Yiming Deng
Nondestructive testing (NDT) methods are widely used in the rail industry to detect and characterize rolling contact fatigue (RCF) defects in railroads, which is very important for railway inspection and maintenance to prevent catastrophic accidents. Existing NDT methods, e.g., ultrasonic testing (UT), magnetic flux leakage (MFL), and eddy current testing (ECT) have been successfully applied in the rail industry, and the state-of-the-art UT method reported recently achieved a high speed of 40 mi/h with a probability of detection (POD) over 80% under 30% false alarms. However, NDT methods still suffer from a bottleneck in that a higher inspection speed causes lower detection sensitivity due to their physical limits, such as negative velocity effect and long sensing time. One of the leading challenges to the rail NDT community is to develop a high-speed high-sensitivity (HSHS) capability that can provide an improved POD of rail defects in high-speed inspection scenarios over 60 mi/h. This article proposes a horizontal U-shaped magnets-based motion-induced eddy current array (MIECA) method to detect rail surface defects with the HSHS capability. The MIECA method deploys a three-axis magnetic sensor array along the rail transverse direction at the middle of the magnets to measure the MIECA signals, which utilizes the wake effect of the diffused motion-induced eddy current (MIEC) caused by the relative high-speed motion between the magnets and the rail track. Finite-element method (FEM) simulations with a wide speed range from 0 to 62.5 mi/h are carried out to investigate the relationships between the MIEC generation, diffusion and magnitude, and the three-axis MIECA signals. The simulation results show that the higher the speed, the greater the magnitude of diffused MIEC, and the greater the peak-to-peak values of three-axis MIECA signals caused by rail surface defects, which shows a great promise for detecting rail surface defects in high-speed scenarios and is superior inspection relative to existing NDT methods in terms of inspection speed, detection sensitivity, and defect characterization capability.

3 September 2020 in IEEE Access
Verified
Journal Article
Open access
WLWei LU
Wei LU
YWYuning Wei
Yuning Wei
JYJinxia Yuan
Jinxia Yuan
YDYiming Deng
Yiming Deng
ASAiguo Song
Aiguo Song
Nowadays, fieldwork is often accompanied by tight schedules, which tends to strain the shoulder muscles due to high-intensity work. Moreover, it is difficult and stressful for the disabled to drive agricultural machinery. Besides, current artificial intelligence technology could not fully realize tractor autonomous driving because of a high uncertain filed environment and short interruptions of satellite navigation signal shaded by trees. To reduce manual operations, a tractor assistant driving control method was proposed based on the human-machine interface utilizing the electroencephalographic (EEG) signal. First, the EEG signals of the tractor drivers were collected by a low-cost brain-computer interface (BCI), followed by denoising using a wavelet packet. Then the spectral features of EEG signals were calculated and extracted as the input of Recurrent Neural Network (RNN). Finally, the EEG-aided RNN driving model was trained for tractor driving robot control such as straight going, brake, left turn, and right turn operations, which control accuracy was 94.5% and time cost was 0.61 ms. Also, 8 electrodes were selected by the PCA algorithm for the design of a portable EEG controller. And the control accuracy reached 93.1% with the time cost of 0.48 ms. To solve the incomplete driving data set in the actual world because some driving manners may cause dangerous or even death, RNN-TL algorithm was employed by creating the complete driving data in the virtual environment followed by transferring the driving control experience to the actual world with small actual driving data set in the field, which control accuracy was 93.5% and time consumption was 0.48 ms. The experimental results showed the feasibility of the proposed tractor driving control method based on EEG signal combined with RNN-TL deep learning algorithm which can work with the displacement error less than 6.7 mm when the tractor speed is less than 50 km/h.

1 July 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
HSHina Shakir
Hina Shakir
YDYiming Deng
Yiming Deng
HRHaroon Ur Rasheed
Haroon Ur Rasheed
TKTariq Mairaj Rasool Khan
Tariq Mairaj Rasool Khan
Radiomic features based classifiers and neural networks have shown promising results in tumor classification. The classification performance can be further improved greatly by exploring and incorporating the discriminative features towards cancer into mathematical models. In this research work, we have developed two radiomics driven likelihood models in Computed Tomography(CT) images to classify lung, colon, head and neck cancer. Initially, two diagnostic radiomic signatures were derived by extracting 105 3-D features from 200 lung nodules and by selecting the features with higher average scores from several supervised as well as unsupervised feature ranking algorithms. The signatures obtained from both the ranking approaches were integrated into two mathematical likelihood functions for tumor classification. Validation of the likelihood functions was performed on 265 public data sets of lung, colon, head and neck cancer with high classification rate. The achieved results show robustness of the models and suggest that diagnostic mathematical functions using general tumor phenotype can be successfully developed for cancer diagnosis.