Nondestructive testing (NDT) methods are widely used in the rail industry to detect rolling contact damage (RCD) defects to ensure railway safety. With the need of monitoring millions of miles of rail tracks more effectively and efficiently that leads to improved rail safety, reliability, and optimized assets management, the research on high-speed and high-accuracy NDT methods that can obtain high signal-to-noise ratio (SNR) and high sensitivity defect signals at higher speeds is of vital importance. Magnetic flux leakage (MFL) is one of the NDT methods used for high-speed rail inspection, which is suitable for detecting surface and subsurface RCD defects on railhead, but the measured MFL signals are distorted severely by the effect of motion-induced eddy currents (MIEC). However, the fundamental understanding of the mechanism of MIEC generation, distribution, and magnitude is lacking, and the physical interaction between MIEC and MFL measurement during high-speed rail inspection has not been well studied. This article investigates the effect of MIEC on three-axis MFL signals through 3-D finite-element method (FEM) simulations. The 3-D distributions of MIEC and 2-D image signals of MFL measurements for high-speed rail MFL inspection are presented and analyzed. The simulations are conducted with an inspection speed range of 0-62.5 mi/h, and a surface hemisphere-type defect and subsurface hole-type defect are both considered. The results show that the motion between the magnetizer and the rail will generate two types of MIEC, which in turn decreases the peak values of three-axis MFL signals from the subsurface defect and affects the MFL signals spatially, especially the base values along rail transverse and vertical directions. The effect of MIEC on the three-axis MFL signals in terms of SNR, sensitivity, and asymmetry is discussed.
Nondestructive testing (NDT) methods are widely used in the rail industry to detect and characterize rolling contact fatigue (RCF) defects in railroads, which is very important for railway inspection and maintenance to prevent catastrophic accidents. Existing NDT methods, e.g., ultrasonic testing (UT), magnetic flux leakage (MFL), and eddy current testing (ECT) have been successfully applied in the rail industry, and the state-of-the-art UT method reported recently achieved a high speed of 40 mi/h with a probability of detection (POD) over 80% under 30% false alarms. However, NDT methods still suffer from a bottleneck in that a higher inspection speed causes lower detection sensitivity due to their physical limits, such as negative velocity effect and long sensing time. One of the leading challenges to the rail NDT community is to develop a high-speed high-sensitivity (HSHS) capability that can provide an improved POD of rail defects in high-speed inspection scenarios over 60 mi/h. This article proposes a horizontal U-shaped magnets-based motion-induced eddy current array (MIECA) method to detect rail surface defects with the HSHS capability. The MIECA method deploys a three-axis magnetic sensor array along the rail transverse direction at the middle of the magnets to measure the MIECA signals, which utilizes the wake effect of the diffused motion-induced eddy current (MIEC) caused by the relative high-speed motion between the magnets and the rail track. Finite-element method (FEM) simulations with a wide speed range from 0 to 62.5 mi/h are carried out to investigate the relationships between the MIEC generation, diffusion and magnitude, and the three-axis MIECA signals. The simulation results show that the higher the speed, the greater the magnitude of diffused MIEC, and the greater the peak-to-peak values of three-axis MIECA signals caused by rail surface defects, which shows a great promise for detecting rail surface defects in high-speed scenarios and is superior inspection relative to existing NDT methods in terms of inspection speed, detection sensitivity, and defect characterization capability.
22 April 2019 in Research in Nondestructive Evaluation
The magnetic flux leakage (MFL) inspection technology is widely used in pipeline industry to detect defects to ensure pipeline safety. During the high-speed inspection, a relative motion occurred between the pipeline inspection gauge (PIG) and the steel pipe wall will generate motion-induced eddy current (MIEC). There is a lack of research on analyzing the effect of MIEC on high-speed MFL inspection for thick-wall steel pipe. In this article, a three-dimensional (3D) finite-element method (FEM) simulations are conducted with an inspection speed range of 0 m/s to 8 m/s and a wall thickness range of 8 mm to 15 mm. Simulation results show that both high-speed inspection and thick-wall thickness will decrease the magnetization of steel pipe. It is observed that, at the speed of 8 m/s and the thickness of 15 mm, the magnetic field strength is lower than 2 kA/m and the steel pipe exits from the magnetic saturation zone, which causes the severe distortion of three-axis MFL signals, and the signal-to-noise ratio (SNR) is lower than 6 dB. A high-speed PIG is developed here for experiments to measure the three-axis MFL signals. The characteristics of simulated and measured MFL signals are found to be quite consistent.
5 June 2023 in International Journal of Adhesion and Adhesives