John J . Hermans

Dr. John J . Hermans

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2010 in Journal of Anatomy
Verified
Journal Article
Closed access
PDF file
JHJohn J . Hermans
John J . Hermans
ABAnnechien Beumer
Annechien Beumer
TJTon A. W. De Jong
Ton A. W. De Jong
GKGert‐Jan Kleinrensink
Gert‐Jan Kleinrensink

20 October 2011 in Skeletal Radiology
Verified
Journal Article
Open access
PDF file
JHJohn J . Hermans
John J . Hermans
NWN. Wentink
N. Wentink
ABA. Beumer
A. Beumer
WHW. C. J. Hop
W. C. J. Hop
MHM. P. Heijboer
M. P. Heijboer
AGA. Z. Ginai
A. Z. Ginai
Objective Owing to the shortcomings of clinical examination and radiographs, injury to the syndesmotic ligaments is often misdiagnosed. When there is no indication requiring that the fractured ankle be operated on, the syndesmosis is not tested intra-operatively, and rupture of this ligamentous complex may be missed. Subsequently the patient is not treated properly leading to chronic complaints such as instability, pain, and swelling. We evaluated three fracture classification methods and radiographic measurements with respect to syndesmotic injury. Materials and methods Prospectively the radiographs of 51 consecutive ankle fractures were classified according to Weber, AO-Müller, and Lauge-Hansen. Both the fracture type and additional measurements of the tibiofibular clear space (TFCS), tibiofibular overlap (TFO), medial clear space (MCS), and superior clear space (SCS) were used to assess syndesmotic injury. MRI, as standard of reference, was performed to evaluate the integrity of the distal tibiofibular syndesmosis. The sensitivity and specificity for detection of syndesmotic injury with radiography were compared to MRI. Results The Weber and AO-Müller fracture classification system, in combination with additional measurements, detected syndesmotic injury with a sensitivity of 47% and a specificity of 100%, and Lauge-Hansen with both a sensitivity and a specificity of 92%. TFCS and TFO did not correlate with syndesmotic injury, and a widened MCS did not correlate with deltoid ligament injury. Conclusion Syndesmotic injury as predicted by the Lauge-Hansen fracture classification correlated well with MRI findings. With MRI the extent of syndesmotic injury and therefore fracture stage can be assessed more accurately compared to radiographs.

13 January 2022 in Cancers
Verified
Journal Article
Open access
PDF file
NANatália Alves
Natália Alves
MSMegan Schuurmans
Megan Schuurmans
GLGeke Litjens
Geke Litjens
JBJoeran S. Bosma
Joeran S. Bosma
JHJohn J . Hermans
John J . Hermans
HHHenkjan J. Huisman
Henkjan J. Huisman
Early detection improves prognosis in pancreatic ductal adenocarcinoma (PDAC), but is challenging as lesions are often small and poorly defined on contrast-enhanced computed tomography scans (CE-CT). Deep learning can facilitate PDAC diagnosis; however, current models still fail to identify small (<2 cm) lesions. In this study, state-of-the-art deep learning models were used to develop an automatic framework for PDAC detection, focusing on small lesions. Additionally, the impact of integrating the surrounding anatomy was investigated. CE-CT scans from a cohort of 119 pathology-proven PDAC patients and a cohort of 123 patients without PDAC were used to train a nnUnet for automatic lesion detection and segmentation (nnUnet_T). Two additional nnUnets were trained to investigate the impact of anatomy integration: (1) segmenting the pancreas and tumor (nnUnet_TP), and (2) segmenting the pancreas, tumor, and multiple surrounding anatomical structures (nnUnet_MS). An external, publicly available test set was used to compare the performance of the three networks. The nnUnet_MS achieved the best performance, with an area under the receiver operating characteristic curve of 0.91 for the whole test set and 0.88 for tumors <2 cm, showing that state-of-the-art deep learning can detect small PDAC and benefits from anatomy information.

26 August 2011 in BMC Surgery
Verified
Journal Article
Open access
PDF file
JHJoris J Harlaar
Joris J Harlaar
EDEva B Deerenberg
Eva B Deerenberg
GRGabrielle H van Ramshorst
Gabrielle H van Ramshorst
HLHarold E Lont
Harold E Lont
EBEd Cmh van der Borst
Ed Cmh van der Borst
JLJohan F Lange
Johan F Lange
The median laparotomy is frequently used by abdominal surgeons to gain rapid and wide access to the abdominal cavity with minimal damage to nerves, vascular structures and muscles of the abdominal wall. However, incisional hernia remains the most common complication after median laparotomy, with reported incidences varying between 2-20%. Recent clinical and experimental data showed a continuous suture technique with many small tissue bites in the aponeurosis only, is possibly more effective in the prevention of incisional hernia when compared to the common used large bite technique or mass closure. The STITCH trial is a double-blinded multicenter randomized controlled trial designed to compare a standardized large bite technique with a standardized small bites technique. The main objective is to compare both suture techniques for incidence of incisional hernia after one year. Secondary outcomes will include postoperative complications, direct costs, indirect costs and quality of life. A total of 576 patients will be randomized between a standardized small bites or large bites technique. At least 10 departments of general surgery and two departments of oncological gynaecology will participate in this trial. Both techniques have a standardized amount of stitches per cm wound length and suture length wound length ratio's are calculated in each patient. Follow up will be at 1 month for wound infection and 1 year for incisional hernia. Ultrasound examinations will be performed at both time points to measure the distance between the rectus muscles (at 3 points) and to objectify presence or absence of incisional hernia. Patients, investigators and radiologists will be blinded during follow up, although the surgeon can not be blinded during the surgical procedure. The STITCH trial will provide level 1b evidence to support the preference for either a continuous suture technique with many small tissue bites in the aponeurosis only or for the commonly used large bites technique. Clinicaltrials.gov NCT01132209

1 September 2023 in Radiology
Verified
Journal Article
Closed access
NANatália Alves
Natália Alves
JBJoeran S. Bosma
Joeran S. Bosma
KVKiran V. Venkadesh
Kiran V. Venkadesh
CJColin Jacobs
Colin Jacobs
ZSZaigham Saghir
Zaigham Saghir
HHHenkjan J. Huisman
Henkjan J. Huisman
Background A priori identification of patients at risk of artificial intelligence (AI) failure in diagnosing cancer would contribute to the safer clinical integration of diagnostic algorithms. Purpose To evaluate AI prediction variability as an uncertainty quantification (UQ) metric for identifying cases at risk of AI failure in diagnosing cancer at MRI and CT across different cancer types, data sets, and algorithms. Materials and Methods Multicenter data sets and publicly available AI algorithms from three previous studies that evaluated detection of pancreatic cancer on contrast-enhanced CT images, detection of prostate cancer on MRI scans, and prediction of pulmonary nodule malignancy on low-dose CT images were analyzed retrospectively. Each task's algorithm was extended to generate an uncertainty score based on ensemble prediction variability. AI accuracy percentage and partial area under the receiver operating characteristic curve (pAUC) were compared between certain and uncertain patient groups in a range of percentile thresholds (10%-90%) for the uncertainty score using permutation tests for statistical significance. The pulmonary nodule malignancy prediction algorithm was compared with 11 clinical readers for the certain group (CG) and uncertain group (UG). Results In total, 18 022 images were used for training and 838 images were used for testing. AI diagnostic accuracy was higher for the cases in the CG across all tasks (P < .001). At an 80% threshold of certain predictions, accuracy in the CG was 21%-29% higher than in the UG and 4%-6% higher than in the overall test data sets. The lesion-level pAUC in the CG was 0.25-0.39 higher than in the UG and 0.05-0.08 higher than in the overall test data sets (P < .001). For pulmonary nodule malignancy prediction, accuracy of AI was on par with clinicians for cases in the CG (AI results vs clinician results, 80% [95% CI: 76, 85] vs 78% [95% CI: 70, 87]; P = .07) but worse for cases in the UG (AI results vs clinician results, 50% [95% CI: 37, 64] vs 68% [95% CI: 60, 76]; P < .001). Conclusion An AI-prediction UQ metric consistently identified reduced performance of AI in cancer diagnosis. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Babyn in this issue.

13 June 2010 in Skeletal Radiology
Verified
Journal Article
Open access
PDF file
JHJohn J . Hermans
John J . Hermans
AGAbida Z. Ginai
Abida Z. Ginai
NWNoortje Wentink
Noortje Wentink
WHWim C. J. Hop
Wim C. J. Hop
ABAnnechien Beumer
Annechien Beumer
Objective The optimal MRI scan planes of collateral ligaments of the ankle have been described extensively, with the exception of the syndesmotic ligaments. We assessed the optimal scan plane for depicting the distal tibiofibular syndesmosis. Materials and Methods In order to determine the optimal oblique caudal-cranial and lateral-medial MRI scan plane, two fresh frozen cadaveric ankles were used. The angle of the scan plane that demonstrated the anterior and posterior distal tibiofibular ligament uninterrupted in their full length was determined. In a prospective study this oblique scan plane was then used in addition to the axial and coronal planes, for MRI scans of both ankles in 21 healthy volunteers. Two observers independently evaluated the anterior tibiofibular ligament (ATIFL) and posterior tibiofibular ligament (PTIFL) regarding the continuity of the individual fascicles, thickness and wavy contour of the ligaments in both the axial and the oblique plane. Kappa was calculated to determine the interobserver agreement. McNemar’s test was used to statistically quantify the significance of the two scan planes. Results In the axial plane the ATIFL was in 31% (13/42) partly and in 69% (29/42) completely discontinuous; in the oblique plane the ATIFL was continuous in 88% (37/42) and partly discontinuous in 12% (5/42). Compared with the axial plane, the oblique plane demonstrated significantly less discontinuity (p < 0.001), but not significantly less thickening (p = 1.00) or less wavy contour (p = 0.06) of the ATIFL. In the axial scan plane the PTIFL was continuous in 76% (32/42), partially discontinuous in 19% (8/42) and completely discontinuous in 5% (2/42); in the oblique plane the PTIFL was continuous in 100% (42/42). Compared with the axial plane, the oblique plane demonstrated significantly less discontinuity (p = 0.002), but not significantly less thickening (p = 1.00) or less wavy contour (p = 0.50) of the PTIFL. The interobserver agreement score and kappa (κ) regarding the continuity for the ATIFL in the axial and oblique planes was 91% (κ = 0.79) and 91% (κ = 0.55) respectively; for the PTIFL it was 86% (κ = 0.65) and 100% (κ = not defined). Conclusion The ATIFL and PTIFL are routinuely scanned in the orthogonal planes. The advantage of MRI scanning in an oblique image plane of about 45 degrees permits a better evaluation of the ligaments compared with the axial plane, particularly a better interpretation of ligament continuity, thickening and wavy contour. This may lead to a reduction in false-positive results, especially regarding partial or complete ligament ruptures. This can be of considerable aid in therapeutic management.