Andreas Boss

Dr. Andreas Boss

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2011 in European Radiology
Verified
Journal Article
Closed access
PDF file
ABAndreas Boss
Andreas Boss
LSLars Stegger
Lars Stegger
SBSotirios Bisdas
Sotirios Bisdas
AKArmin Kolb
Armin Kolb
NSNina Schwenzer
Nina Schwenzer
CPChristina Pfannenberg
Christina Pfannenberg

1 November 2016 in European Journal of Radiology
Verified
Journal Article
Closed access
ABAndreas Boss
Andreas Boss
BBBorna Barth
Borna Barth
LFLukas Filli
Lukas Filli
DKDavid Kenkel
David Kenkel
MWMoritz C. Wurnig
Moritz C. Wurnig
CRCaecilia S. Reiner
Caecilia S. Reiner

1 December 2014 in Investigative Radiology
Verified
Journal Article
Closed access
LFLukas Filli
Lukas Filli
MWMoritz Wurnig
Moritz Wurnig
DNDaniel Nanz
Daniel Nanz
RLRoger Luechinger
Roger Luechinger
DKDavid Kenkel
David Kenkel
ABAndreas Boss
Andreas Boss
Introduction Diffusion kurtosis imaging (DKI) is based on a non-Gaussian diffusion model that should inherently better account for restricted water diffusion within the complex microstructure of most tissues than the conventional diffusion-weighted imaging (DWI), which presumes Gaussian distributed water molecule displacement probability. The aim of this investigation was to test the technical feasibility of in vivo whole-body DKI, probe for organ-specific differences, and compare whole-body DKI and DWI results. Materials and Methods Eight healthy subjects underwent whole-body DWI on a clinical 3.0 T magnetic resonance imaging system. Echo-planar images in the axial orientation were acquired at b-values of 0, 150, 300, 500, and 800 mm2/s. Parametrical whole-body maps of the diffusion coefficient (D), the kurtosis (K), and the traditional apparent diffusion coefficient (ADC) were generated. Goodness of fit was compared between DKI and DWI fits using the sums of squared residuals. Data groups were tested for significant differences of the mean by paired Student t tests. Results Good-quality parametrical whole-body maps of D, K, and ADC could be computed. Compared with ADC values, D values were significantly higher in the cerebral gray matter (by 30%) and white matter (27%), renal cortex (23%) and medulla (21%), spleen (101%), as well as erector spinae muscle (34%) (each P value <0.001). No significant differences between D and ADC were found in the cerebrospinal fluid (P = 0.08) and in the liver (P = 0.13). Curves of DKI fitted the measurement points significantly better than DWI curves did in most organs. Conclusions Whole-body DKI is technically feasible and may reflect tissue microstructure more meaningfully than whole-body DWI.

1 November 2018 in Heliyon
Verified
Journal Article
Open access
DSDaniel Stocker
Daniel Stocker
HMHerman P. Marquez
Herman P. Marquez
MWMatthias W. Wagner
Matthias W. Wagner
DRDimitri A. Raptis
Dimitri A. Raptis
PCPierre-Alain Clavien
Pierre-Alain Clavien
MWMoritz C. Wurnig
Moritz C. Wurnig
To find potentially diagnostic texture analysis (TA) features and to evaluate the diagnostic accuracy of two-dimensional (2D) magnetic resonance (MR) TA for differentiation between hepatocellular carcinoma (HCC) and benign hepatocellular tumors in the non-cirrhotic liver in an exploratory MR-study. 108 non-cirrhotic patients (62 female; 41.5 ± 18.3 years) undergoing preoperative contrast-enhanced MRI were retrospectively included in this multi-center-study. TA including gray-level histogram, co-occurrence and run-length matrix features (total 19 features) was performed by two independent readers. Native fat-saturated-T1w and T2w as well as arterial and portal-venous post contrast-enhanced 2D-image-slices were assessed. Conventional reading was performed by two separate independent readers. Differences in TA features between HCC and benign lesions were investigated using independent sample t-tests. Logistic regression analysis was performed to obtain the optimal number/combination of TA-features and diagnostic accuracy of TA analysis. Sensitivity and specificity of the better performing radiologist were compared to TA analysis. The highest number of significantly differing TA-features (n = 5) was found using the arterial-phase images including one gray-level histogram (skewness, p = 0.018) and four run-length matrix features (all, p < 0.02). The optimal binary logistic regression model for TA-features of the arterial-phase images contained 13 parameters with an accuracy of 84.5% (sensitivity 84.1%, specificity 84.9%) and area-under-the-curve of 0.92 (95%-confidence-interval 0.85-0.98) for diagnosis of HCC. Conventional reading yielded a significantly lower sensitivity (63.6%, p = 0.027) and no significant difference in specificity (94.6%, p = 0.289) at best. 2D-TA of MR images is a feasible objective method that may help to distinguish HCC from benign hepatocellular tumors in the non-cirrhotic liver. Most promising results were found in TA features in the arterial phase images.

13 June 2022 in Clinical and Translational Gastroenterology
Verified
Journal Article
Open access
ACAlexandre Coimbra
Alexandre Coimbra
JRJordi Rimola
Jordi Rimola
Miriam CuatrecasasMiriam Cuatrecasas
Miriam Cuatrecasas
GHGert De Hertogh
Gert De Hertogh
GAGert Van Assche
Gert Van Assche
JPJulián Panés
Julián Panés
INTRODUCTION: Magnetic resonance enterography (MRE) is useful for detecting bowel strictures, whereas a number of imaging biomarkers may reflect severity of fibrosis burden in Crohn's disease (CD). This study aimed to verify the association of MRE metrics with histologic fibrosis independent of inflammation. METHODS: This prospective European multicenter study performed MRE imaging on 60 patients with CD with bowel strictures before surgical resection. Locations of 61 histological samples were annotated on MRE examinations, followed by central readings using the Chiorean score and measurement of delayed gain of enhancement (DGE), magnetization transfer ratio, T2-weighted MRI sequences (T2R), apparent diffusion coefficient (ADC), and the magnetic resonance index of activity (MaRIA). Correlations of histology and MRE metrics were assessed. Least Absolute Shrinkage and Selection Operator and receiver operator characteristic (ROC) curve analyses were used to select composite MRE scores predictive of histology and to estimate their predictive value. RESULTS: ADC and MaRIA correlated with fibrosis (R = −0.71, P < 0.0001, and 0.59, P < 0.001) and more moderately with inflammation (R = −0.35, P < 0.01, and R = 0.53, P < 0.001). Lower or no correlations of fibrosis or inflammation were found with DGE, magnetization transfer ratio, or T2R. Least Absolute Shrinkage and Selection Operator and ROC identified a composite score of MaRIA, ADC, and DGE as a very good predictor of histologic fibrosis (ROC area under the curve = 0.910). MaRIA alone was the best predictor of histologic inflammation with excellent performance in identifying active histologic inflammation (ROC area under the curve = 0.966). Discussion: MRE-based scores for histologic fibrosis and inflammation may assist in the characterization of CD stenosis and enable development of fibrosis-targeted therapies and clinical treatment of stenotic patients.

20 December 2014 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
JGJeanne M Gunzinger
Jeanne M Gunzinger
GDGaspar Delso
Gaspar Delso
ABAndreas Boss
Andreas Boss
MPMiguel Porto
Miguel Porto
HDHelen Davison
Helen Davison
IBIrene A. Burger
Irene A. Burger
Background: Hybrid positron emission tomography/magnetic resonance imaging (PET/MRI) shows high potential for patients with oropharyngeal cancer. Dental implants can cause substantial artifacts in the oral cavity impairing diagnostic accuracy. Therefore, we evaluated new MRI sequences with multi-acquisition variable-resonance image combination (MAVRIC SL) in comparison to conventional high-bandwidth techniques and in a second step showed the effect of artifact size on MRI-based attenuation correction (AC) with a simulation study. Methods: Twenty-five patients with dental implants prospectively underwent a trimodality PET/CT/MRI examination after informed consent was obtained under the approval of the local ethics committee. A conventional 3D gradient-echo sequence (LAVA-Flex) commonly used for MRI-based AC of PET (acquisition time of 14 s), a T1w fast spin-echo sequence with high bandwidth (acquisition time of 3.2 min), as well as MAVRIC SL sequence without and with increased phase acceleration (MAVRIC, acquisition time of 6 min; MAVRIC-fast, acquisition time of 3.5 min) were applied. The absolute and relative reduction of the signal void artifact was calculated for each implant and tested for statistical significance using the Wilcoxon signed-rank test. The effect of artifact size on PET AC was simulated in one case with a large tumor in the oral cavity. The relative difference of the maximum standardized uptake value (SUVmax) in the tumor was calculated for increasing artifact sizes centered over the second molar. Results: The absolute reduction of signal void from LAVA-Flex sequences to the T1-weighted fast spin-echo (FSE) sequences was 416 mm2 (range 4 to 2,010 mm2) to MAVRIC 481 mm2 (range 12 to 2,288 mm2) and to MAVRIC-fast 486 mm2 (range 39 to 2,209 mm2). The relative reduction in signal void was significantly improved for both MAVRIC and MAVRIC-fast compared to T1 FSE (−75%/− 78% vs. − 62%, p < 0.001 for both). The relative error for SUVmax was negligible for artifacts of 0.5-cm diameter (−0.1%), but substantial for artifacts of 5.2-cm diameter (−33%). Conclusions: MAVRIC-fast could become useful for artifact reduction in PET/MR for patients with dental implants. This might improve diagnostic accuracy especially for patients with tumors in the oropharynx and substantially improve accuracy of PET quantification.