Katarzyna Chliszcz

Ms. Katarzyna Chliszcz

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2022 in Energies
Verified
Journal Article
Open access
PDF file
Marcin KruzelMarcin Kruzel
Marcin Kruzel
Tadeusz BohdalTadeusz Bohdal
Tadeusz Bohdal
KDKrzysztof Dutkowski
Krzysztof Dutkowski
WKWaldemar Kuczyński
Waldemar Kuczyński
KCKatarzyna Chliszcz
Katarzyna Chliszcz
This paper is an introduction to the cycle proposed by the authors related to research directions concerning the problems of condensation of zeotropic refrigerant mixtures. For over a hundred years, research has been conducted on the search for new working fluids in the cycles for cooling devices and heat pumps. Initially, the natural refrigerants used were replaced with homogeneous synthetic refrigerants, followed by mixtures of two or more refrigerants. Among the mixtures, there are azeotropic and zeotropic mixtures. In the case of an azeotrope mixture, a liquid solution of two or more chemical compounds is in thermodynamic equilibrium with the saturated vapor resulting from this mixture. The chemical composition of the liquid and vapor is identical. A zeotropic mixture is a liquid-vapor system in which the composition of a liquid mixture (solution) of two or more chemical compounds is always different from that of the saturated vapor generated from this liquid. This is due to the different boiling and condensation temperatures of the individual components of the mixture at the same pressure. There is a so-called temperature glide. The phase transformations of individual components do not run simultaneously, which means that the boiling or condensation phase transition temperature changes during the process being carried out. This raises a number of computational, design, and operational problems for power equipment. Today, however, zeotropic mixtures find an alternative to refrigerants with a high GWP potential. Despite the disadvantage of temperature glide, they also have advantages. These include ecological, energy, and economic indicators. As a result, they are increasingly used in the energy economy. This prompts researchers to conduct further research in the field of a detailed description of the phenomenon of boiling and condensation phase transformations of zeotropic mixtures under temperature glide, searching for new computational relationships, new design solutions, and applications. It is still an insufficiently recognized research problem. Bearing the above in mind, the authors made an attempt to review the state of knowledge in this area. Particular attention was paid to the progress in modeling the condensation phenomenon of zeotropic mixtures for application in compact heat exchangers. Miniaturization of cooling devices creates great application possibilities in this area.

16 January 2021 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
WKWaldemar Kuczyński
Waldemar Kuczyński
HCHenryk Charun
Henryk Charun
PPPiotr Piątkowski
Piotr Piątkowski
Błażej BałaszBłażej Bałasz
Błażej Bałasz
KCKatarzyna Chliszcz
Katarzyna Chliszcz

14 March 2022 in Energies
Verified
Journal Article
Open access
PDF file
WKWaldemar Kuczyński
Waldemar Kuczyński
Marcin KruzelMarcin Kruzel
Marcin Kruzel
KCKatarzyna Chliszcz
Katarzyna Chliszcz
This paper presents the results of experimental research and mathematical modelling in terms of the influence periodic dynamic instabilities have on condensation phase change in R1234yf and R1234ze refrigerants in tubular minichannels. The main reason for this research was the fact that under the Montreal Protocol (1986), as well as Regulation No 517/2014 of the European Parliament and of the Council of 16 April 2014, the F-gases such as hydrofluorocarbons (HFC), perfluorocarbons (PFC), sulphur hexafluoride, and other agents containing fluorine have to be withdrawn. This includes one of the most commonly used refrigerants—R134a—which, since 1 January 2017, has already been withdrawn. It also includes the R404A refrigerant. R1234ze and R1234yf are suggested as substitutions for R134a. The basic parameters determining the application of those agents are their global warming potential (GWP) indicator, which is below 150, and reduction in fluorinated greenhouse gases emission by a third, simply by withdrawing them (with 2010 as a reference level). The current state of knowledge enables researchers to foresee the influence of some hydrodynamic instabilities on the condensation of fluorinated refrigerants in minichannels. Therefore, an expansion of this knowledge regarding the suggested substitutes is absolutely necessary. Research concerning the condensation in minichannels under dynamic instabilities was already conducted for the refrigerants currently being withdrawn. However, the influence of those instabilities on a phase change in the suggested pro-ecologic substitutes is not known. It is known that during the condensation of refrigerants under dynamic instabilities, the propagation of instabilities occurs in a waveform. Two-phase media are particularly susceptible to this phenomenon. Propagation of instabilities in the form of acoustic wave or wave change in other parameters such as temperature, the density of mass, or heat flux plays a special role. All of them have their own characteristics, with evidently different propagation velocities. Both mechanisms include irreversible dissipation and dispersion. The dissipative effects, by their irreversibility, cause entropy generation and dump the instability propagation in a two-phase medium. The dispersive effects influence the instability propagation that is a function of the generation frequency. Besides the experimental results, the paper contains a dimensional analysis procedure based on the Π–Buckingham theorem that has allowed for the development of a regressive model for the velocities of pressure dynamic instabilities. The experimental part of this paper was conducted using tubular minichannels with an internal diameter of dID = 1.40–3.3 mm.

28 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
WKWaldemar Kuczyński
Waldemar Kuczyński
Marcin KruzelMarcin Kruzel
Marcin Kruzel
KCKatarzyna Chliszcz
Katarzyna Chliszcz
This paper presents experimental research and mathematical modeling data concerning the impact of unit dynamic instabilities on the phase-transition condensation processes of the zeotropic mixtures R404A and R448A and azeotropic R507A refrigerants in pipe minichannels. The R507 refrigerant is currently used as a temporary substitute for R404A, whereas R448A is a sustainable prospective substitute for R404A. The study presents experimental testing data for the condensation processes of these refrigerants in pipe minichannels and a proposal for the use of dimensional analysis, including the Π-Buckingham theorem, to determine the regression relationship explaining the propagation of unit dynamic instabilities. Based on the experimental studies performed, regression computational models were developed and showed satisfactory agreement in the range of 20% to 25%. They give the possibility to identify, in a utilitarian, way the speed of propagation of temperature and pressure instabilities during the liquefaction of refrigerants. The study was carried out on pipe minichannels with an internal diameter of di = 3.3, 2.3, 1.92, 1.44 and 1.40 mm.

26 June 2025 in Materials
Verified
Journal Article
Open access
PDF file
KCKatarzyna Chliszcz
Katarzyna Chliszcz
DLDorota Laskowska
Dorota Laskowska
WKWaldemar Kuczyński
Waldemar Kuczyński
Błażej BałaszBłażej Bałasz
Błażej Bałasz
Maciej Bartłomiej KasperowiczMaciej Bartłomiej Kasperowicz
Maciej Bartłomiej Kasperowicz
KMKevin Moj
Kevin Moj
The miniaturization of heat exchangers requires advanced manufacturing methods, as conventional techniques such as milling or casting are insufficient for producing complex microscale geometries. This study investigates the feasibility of using selective laser melting (SLM) with 316L stainless steel powder to fabricate compact heat exchangers with minichannels. The exchanger was designed using Autodesk Inventor 2023.3 software and produced under optimized process parameters. Measurements using a hydrostatic balance demonstrated that the applied process parameters resulted in a relative material density of 99.5%. The average microhardness in the core region of the SLM-fabricated samples was 255 HV, and the chemical composition of the final material differed only slightly from that of the feedstock material (stainless steel powder). Dimensional accuracy, surface quality, and internal structure integrity were assessed using computed tomography, optical microscopy, and contact profilometry. The fabricated component demonstrated high geometric fidelity and channel permeability, with local surface deformations associated with the absence of support structures. The average surface roughness (Ra) of the minichannels was 11.11 ± 1.63 µm. The results confirm that SLM technology enables the production of functionally viable heat exchangers with complex geometries. However, limitations remain regarding dimensional accuracy, powder removal, and surface roughness. These findings highlight the potential of metal additive manufacturing for heat transfer applications while emphasizing the need for further research on performance testing under real operating conditions, especially involving two-phase flow.