Álvaro Roberto Gardenghi

Álvaro Roberto Gardenghi


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 November 2020 in Fluids
Verified
Journal Article
Open access
PDF file
ÁGÁlvaro Roberto Gardenghi
Álvaro Roberto Gardenghi
EFErivelto dos Santos Filho
Erivelto dos Santos Filho
DCDaniel Gregório Chagas
Daniel Gregório Chagas
GSGuilherme Scagnolatto
Guilherme Scagnolatto
RORodrigo Oliveira
Rodrigo Oliveira
CTCristiano Bigonha Tibiriça
Cristiano Bigonha Tibiriça
Void fraction is one of the most important parameters for the modeling and characterization of two-phase flows. This manuscript presents an overview of void fraction measurement techniques, experimental databases and correlations, in the context of microchannel two-phase flow applications. Void fraction measurement techniques were reviewed and the most suitable techniques for microscale measurements were identified along its main characteristics. An updated void fraction experimental database for small channel diameter was obtained including micro and macrochannel two-phase flow data points. These data have channel diameter ranging from 0.5 to 13.84 mm, horizontal and vertical directions, and fluids such as air-water, R410a, R404a, R134a, R290, R12 and R22 for both diabatic and adiabatic conditions. New published void fraction correlations as well high cited ones were evaluated and compared to this small-diameter void fraction database in order to quantify the prediction error of them. Moreover, a new drift flux correlation for microchannels was also developed, showing that further improvement of available correlations is still possible. The new correlation was able to predict the microchannel database with mean absolute relative error of 9.8%, for 6% of relative improvement compared to the second-best ranked correlation for small diameter channels.

25 March 2022 in Entropy
Verified
Journal Article
Open access
PDF file
VMVinicius Akyo Matsuda
Vinicius Akyo Matsuda
ÁGÁlvaro Roberto Gardenghi
Álvaro Roberto Gardenghi
CTCristiano Bigonha Tibiriça
Cristiano Bigonha Tibiriça
LCLuben Cabezas-Gómez
Luben Cabezas-Gómez
In this work, a transient analysis of a dual-skin chest-freezer refrigeration system, operating with R290, is studied numerically with the purpose of performing the characterization of the system through the second law of thermodynamics. A mathematical model which accounts for refrigerant mass distribution inside the system is used. In addition, this work addresses the calculation of entropy generation and exergy destruction for characterizing the system performance during its operations. In order to validate the model, a comparison with measured experimental data is performed for both pull-down and on-off operations. The characterization of the system through the second law of thermodynamics is conducted using two different methods. One consists of a direct calculation of the entropy generation rate and the second one in the calculation of exergy destruction rate. The equivalence of these two methods is used as an indicative of the “correctness” of the performed calculations. The model results agree near 97% with the experimental data used in the comparisons. Entropy generation and exergy destruction results along time for the whole system and in its individual components are characterized with the second law. These results are very useful for improving refrigeration system design.

17 April 2023 in Thermal Science and Engineering Progress
Verified
Journal Article
Closed access
ÁGÁlvaro Roberto Gardenghi
Álvaro Roberto Gardenghi
JLJônatas Ferreira Lacerda
Jônatas Ferreira Lacerda
MGMatheus dos Santos Guzella
Matheus dos Santos Guzella
CTCristiano Bigonha Tibiriça
Cristiano Bigonha Tibiriça
LCLuben Cabezas-Gómez
Luben Cabezas-Gómez

1 March 2021 in The Academic Society Journal
Verified
Journal Article
Closed access
EFEduardo P Falcetti
Eduardo P Falcetti
ÁGÁlvaro Roberto Gardenghi
Álvaro Roberto Gardenghi
ADAlvaro B Dietrich
Alvaro B Dietrich
LCLuben Cabezas-Gómez
Luben Cabezas-Gómez
It is presented a hermetic compressor startup simulation procedure considering a simplified approach to obtain the transient data of different compressor parameters. The main numerical technique is a four order Runge-Kutta procedure to numerically integrate the systems of ordinary differential equations, which describe the variables’ variation with time in each part of the compressor. The simulations were performed in the Windali software. The results show how the oil viscosity influences the electrical motor torque, the compressor load and crankshaft angular velocity with time for two electric motor input voltage values. The increase of oil viscosity by a factor of 2, retards the compressor startup for more than one second. The presented simple model could be valuable for studying the geometrical and operational influence on compressor startup.