Background: Infrared thermography can be used to obtain more complete information about a patient’s condition. The method can be used in various medical applications for monitoring acute and chronic orofacial pain syndrome. With this diagnostic method, thermal differences in the examined region are usually compared to the same reference region on the opposite side of the body. Methods: Infrared quantitative thermography is a non-invasive method for contactless monitoring of dynamic thermal fields on a surface, or in this case, the human body. This method is based on detection of infrared radiation, which is naturally emitted from the surface of the body. In a pilot project with a patient having orofacial pain, changes before and after repetitive transcranial magnetic brain stimulation treatment were assessed. Results: First-day measurements found significantly higher maximum, minimum, and average temperatures, before and after therapy, in the area where the patient subjectively reported pain. The fifth and final measurements, before and after therapy, found only a slight elevation of the maximum temperature of the assessed regions, relative to the same regions on the opposite side of the face. Conclusion: During the measurements on the fifth day, a thermal difference greater than 0.4°C was only observed relative to the minimum temperatures associated with the regions of self-reported pain before and after therapy. For validation of the effects, this method will need to be tested using a randomized, double-blind study with a larger number of patients.
Homebalance Stability medical device, based on audio-visual feedback and Nintendo Wii Balance Board, is a suitable tool for telerehabilitation of balance issues in patients with brain damage. The main goal was to expand the system by energy expenditure measurements and to verify the usability of the telemetric mobile device FlexiGuard. We used the FlexiGuard system (developed at our institute) and Oxycon (JAEGER® Oxycon Mobile, Germany) to measure the energy expenditure. We performed measurements on eight probands. Each proband underwent six activities for a total length of 90 min. During these activities, we measured energy expenditure using Oxycon and heart rate using the FlexiGuard system, from which we calculated the energy expenditure. By comparing the energy expenditure from measuring the heart rate with the FlexiGuard system with that from the Oxycon reference device, we verified the applicability of the FlexiGuard system for estimation energy expenditure. The average deviation from the reference instrument was under 30%. The conventional method, such as Oxycon, cannot be used during home therapy. Therefore, we upgraded the platform of our telemetry system (FlexiGuard), which can measure the heart rate and calculate the energy expenditure.
The present review aims to 1) provide a comprehensive overview of remote patient monitoring (RPM) across the existing research literature involving people with MS (pwMS) and 2) provide updated information on the availability of these technologies. A systematic literature search was conducted in PubMed, Embase, Web of Science and Scopus. Studies were included if they evaluated adult pwMS, applied RPM over at least 1 week, and reported objective outcomes. Included studies were categorised as evaluating apps, wearables or combinations of the two. A total of 77 studies involving 9463 pwMS were included. Participants had a mean age of 46 years, 69.7% were female, and most presented with mild to moderate disability (EDSS 2-3.5). Wearables were used in 37 studies, 33 employed apps and 4 combined both. Wearables were most commonly wrist-worn, primarily assessing step count and gait, while mobile apps focused on motor function, cognition and quality of life. Most wearables and apps remain restricted to research use, with only few being commercially available. Application of RPM in MS is promising, offering broad possibilities for monitoring health status, but is limited by device heterogeneity and restricted availability. Future efforts should prioritise standardised, multi-domain RPM solutions that ensure data security and broad clinical applicability.