Detection of lung sounds and their propagation is a powerful tool for analysing the behaviour of the respiratory system. A common approach to detect the respiratory sounds is lung auscultation, however, this method has significant limitations including low sensitivity of human ear or ambient background noise. This article targets the major limitations of lung auscultation and presents a new approach to analyse the respiratory sounds and visualise them together with the respiratory phases. The respiratory sounds from 41 patients were recorded and filtered to eliminate the ambient noise and noise artefacts. The filtered signal is processed to identify the respiratory phases. The article also contains an approach for removing the noise that is very difficult to filter but the removal is crucial for identifying the respiratory phases. Finally, the respiratory phases are overlaid with the frequency spectrum which simplifies the orientation in the recording and additionally offers the information on the inter-individual ratio of the inhalation and exhalation phases. Such interpretation provides a powerful tool for further analysis of lung sounds, simplifythe diagnosis of various types of respiratory tract dysfunctions, and returns data which are comparable among the patients.
Homebalance Stability medical device, based on audio-visual feedback and Nintendo Wii Balance Board, is a suitable tool for telerehabilitation of balance issues in patients with brain damage. The main goal was to expand the system by energy expenditure measurements and to verify the usability of the telemetric mobile device FlexiGuard. We used the FlexiGuard system (developed at our institute) and Oxycon (JAEGER® Oxycon Mobile, Germany) to measure the energy expenditure. We performed measurements on eight probands. Each proband underwent six activities for a total length of 90 min. During these activities, we measured energy expenditure using Oxycon and heart rate using the FlexiGuard system, from which we calculated the energy expenditure. By comparing the energy expenditure from measuring the heart rate with the FlexiGuard system with that from the Oxycon reference device, we verified the applicability of the FlexiGuard system for estimation energy expenditure. The average deviation from the reference instrument was under 30%. The conventional method, such as Oxycon, cannot be used during home therapy. Therefore, we upgraded the platform of our telemetry system (FlexiGuard), which can measure the heart rate and calculate the energy expenditure.
The estimation of energy expenditure (EE) is often an integral part of algorithms for wearable electronics. In field practice, procedures based on an indirect estimation of EE from the heart rate (using empirically or statistically based relationships) work correctly only in a narrow range of physical loads, yet they are current considered state of the art. This pilot study aims to experimentally assess novel method using a wide range of input sensors and parameters (heart rate, RR intervals, and 3D motion activity in several places on the body) and neural network (NN) algorithms. Our proposed method consists of training an NN on a specific subject, with a specific set and placement of sensors during the so-called training run, using the golden standard method of indirect calorimetry as a reference. Then, the subject’s EE can be estimated using trained NN. The results of the experiments (carried out on a total of 12 subjects during various physical activities) show a statistically significant improvement in EE estimation with the new prospective method, and it outperforms the state-of-the-art method based on the heart rate and regression model.
Various types of interfering signals are an integral part of ECGs recorded using wearable electronics, specifically during field monitoring, outside the controlled environment of a medical doctor’s office, or laboratory. The frequency spectrum of several types of interfering signals overlaps significantly with the ECG signal, making effective filtration impossible without losing clinically relevant information. In this article, we proceed from the practical assumption that it is unnecessary to analyze the entire ECG recording in real long-term recordings. Conversely, in the preprocessing phase, it is necessary to detect unreadable segments of the ECG signal. This paper proposes a novel method for automatically detecting unreadable segments distorted by superimposed interference in ECG recordings. The method is based on a convolutional neural network (CNN) and is comparable in quality to annotation performed by a medical expert, but incomparably faster. In a series of controlled experiments, the ECG signal was recorded during physical activities of varying intensities, and individual segments of the recordings were manually annotated based on visual assessment by a medical expert, i.e., divided into four different classes based on the intensity of distortion to the useful ECG signal. A deep convolutional model was designed and evaluated, exhibiting a 87.62% accuracy score and the same F1-score in automatic recognition of segments distorted by superimposed interference. Furthermore, the model exhibits an accuracy and F1-score of 98.70% in correctly identifying segments with visually detectable and non-detectable heart rate. The proposed interference detection procedure appears to be sufficiently effective despite its simplicity. It facilitates subsequent automatic analysis of undisturbed ECG waveform segments, which is crucial in ECG monitoring using wearable electronics.
The quantification of skin resistance in individuals after spinal cord injury for the purpose of neurophysiological research is difficult, mainly as a consequence of decreased activity of sweat glands in the injured human organism. In this original work, we propose a custom electrical skin resistance transducer, featuring extremely low patient auxiliary current, linear response and high dynamic range. After the design and fabrication of the prototype device, we conducted preliminary benchmark tests. We found that our prototype transducer was able to linearly report a broad range of resistance presented to its input terminals, which is not usually found in skin resistance research instrumentation. The basic design idea is viable and, following further research, an improved version of presented prototype device may be used for the purpose of neurophysiological research in individuals after spinal cord injury.