21 February 2020 in IEEE Robotics and Automation Letters
Verified
Journal Article
Open access
MTMartin Tschiersky
Martin Tschiersky
EHEdsko Hekman
Edsko Hekman
DBDannis M. Brouwer
Dannis M. Brouwer
JHJust L. Herder
Just L. Herder
Koichi SuzumoriKoichi Suzumori
Koichi Suzumori
In this paper we demonstrate a pneumatic bending actuator for upper-limb assistive wearable robots which uses thin McKibben muscles in combination with a flexure strip. The actuator features both active soft actuation and passive gravity support, and in terms of force transmission bridges the gap between the classic rigid type actuators and the emerging soft actuator technologies. Its flexure strip leverages the high-force low-displacement properties of McKibben muscles towards a large rotational range of motion and reduces localized forces at the attachments. We explain the synthesis method by which these actuators can be obtained and optimized for high specific moment output. Physical specimens of three optimized actuator designs are built and tested on a dedicated experimental setup, verifying the computational models. Furthermore, a proof-of-concept upper-limb assistive wearable robot is presented to illustrate a practical application of this actuator and its potential for close-to-body alignment. We found that based on our currently available components actuators can be built which, given a width of 80 mm, are able to produce a moment exceeding 4 Nm at an arm elevation of 90 deg.

7 April 2015 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
NSNavid Shahriari
Navid Shahriari
EHEdsko Hekman
Edsko Hekman
MOMatthijs Oudkerk
Matthijs Oudkerk
SMSarthak Misra
Sarthak Misra
Purpose Percutaneous needle insertion procedures are commonly used for diagnostic and therapeutic purposes. Although current technology allows accurate localization of lesions, they cannot yet be precisely targeted. Lung cancer is the most common cause of cancer-related death, and early detection reduces the mortality rate. Therefore, suspicious lesions are tested for diagnosis by performing needle biopsy. Methods In this paper, we have presented a novel computed tomography (CT)-compatible needle insertion device (NID). The NID is used to steer a flexible needle (\({\phi }0.55\,\hbox {mm}\)) with a bevel at the tip in biological tissue. CT images and an electromagnetic (EM) tracking system are used in two separate scenarios to track the needle tip in three-dimensional space during the procedure. Our system uses a control algorithm to steer the needle through a combination of insertion and minimal number of rotations. Results Noise analysis of CT images has demonstrated the compatibility of the device. The results for three experimental cases (case 1: open-loop control, case 2: closed-loop control using EM tracking system and case 3: closed-loop control using CT images) are presented. Each experimental case is performed five times, and average targeting errors are \(2.86\pm 1.14\), \(1.11\pm 0.14\) and \(1.94\pm 0.63\,\hbox {mm}\) for case 1, case 2 and case 3, respectively. Conclusions The achieved results show that our device is CT-compatible and it is able to steer a bevel-tipped needle toward a target. We are able to use intermittent CT images and EM tracking data to control the needle path in a closed-loop manner. These results are promising and suggest that it is possible to accurately target the lesions in real clinical procedures in the future.

13 May 2017 in Medical Engineering & Physics
Verified
Journal Article
Open access
NSNavid Shahriari
Navid Shahriari
WHWout Heerink
Wout Heerink
TKTim van Katwijk
Tim van Katwijk
EHEdsko Hekman
Edsko Hekman
MOMatthijs Oudkerk
Matthijs Oudkerk
SMSarthak Misra
Sarthak Misra
Lung cancer is the most common cause of cancer-related death, and early detection can reduce the mortality rate. Patients with lung nodules greater than 10 mm usually undergo a computed tomography (CT)-guided biopsy. However, aligning the needle with the target is difficult and the needle tends to deflect from a straight path. In this work, we present a CT-compatible robotic system, which can both position the needle at the puncture point and also insert and rotate the needle. The robot has a remote-center-of-motion arm which is achieved through a parallel mechanism. A new needle steering scheme is also developed where CT images are fused with electromagnetic (EM) sensor data using an unscented Kalman filter. The data fusion allows us to steer the needle using the real-time EM tracker data. The robot design and the steering scheme are validated using three experimental cases. Experimental Case I and II evaluate the accuracy and CT-compatibility of the robot arm, respectively. In experimental Case III, the needle is steered towards 5 real targets embedded in an anthropomorphic gelatin phantom of the thorax. The mean targeting error for the 5 experiments is 1.78 ± 0.70 mm. The proposed robotic system is shown to be CT-compatible with low targeting error. Small nodule size and large needle diameter are two risk factors that can lead to complications in lung biopsy. Our results suggest that nodules larger than 5 mm in diameter can be targeted using our method which may result in lower complication rate.

23 July 2019 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Open access
MTMartin Tschiersky
Martin Tschiersky
EHEdsko Hekman
Edsko Hekman
DBDannis M. Brouwer
Dannis M. Brouwer
JHJust L. Herder
Just L. Herder
In this paper we propose a flexure spring based gravity compensation device which provides assistance to lift the forearm. Three different spring designs are obtained and evaluated. The synthesis method to obtain these is explained in detail and an experimental evaluation validates the desired gravity balancing properties. It is found that in comparison to a flexure spring with constant thickness, a variable thickness distribution along the spring leads to a drastic reduction of its width, which amounts to 81 % in the presented case, and offers an energy to weight ratio that is 94 % higher. Employing a nested spring design further increases the storable elastic energy of the variable thickness design by 145 % through utilization of the otherwise unused space within the original spring envelope. A proof-of-concept prototype is built to illustrate a practical implementation. The presented synthesis method provides a tool to obtain gravity balancing flexure springs that offer a promising solution for the design of assistive devices which aim to be both wearable and inconspicuous.

28 June 2021 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
CHChristoff Heunis
Christoff Heunis
KBKasper J. Behrendt
Kasper J. Behrendt
EHEdsko Hekman
Edsko Hekman
CMCyril Moers
Cyril Moers
JVJean-Paul P.M. de Vries
Jean-Paul P.M. de Vries
SMSarthak Misra
Sarthak Misra
Arterial stenosis is a high-risk disease accompanied by large amounts of calcified deposits and plaques that develop inside the vasculature. These deposits should be reduced to improve blood flow. However, current methods used to reduce stenosis require externally controlled actuation systems resulting in limited workspace or patient risks. This results in an unexplored preference regarding the revascularization strategy for symptomatic artery stenosis. In this article, we propose a novel internally actuated solution: a magnetic spring-loaded rotablation catheter. The catheter is developed to achieve stenosis-debulking capabilities by actuating drill bits using two internal electromagnetic coils and a magnetic reciprocating spring-loaded shaft. The state-space model of the catheter is validated by comparing the simulation results of the magnetic fields of the internal coils with the experimental results of a fabricated prototype. Contact forces of the catheter tip are measured experimentally, resulting in a maximum axial force of 2.63 N and a torque of 5.69 mN-m. Finally, we present interventions in which the catheter is inserted to reach a vascular target site and demonstrate plaque-specific treatment using different detachable actuator bits. Calcified deposits are debulked and visualized via ultrasound imaging. The catheter can reduce a stenosis cross-sectional area by up to 35%, indicating the potential for the treatment of calcified lesions, which could prevent restenosis.

8 February 2023 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
CHClaudia J. W. Haarman
Claudia J. W. Haarman
EHEdsko Hekman
Edsko Hekman
JRJohan S. Rietman
Johan S. Rietman
HKHerman Van Der Kooij
Herman Van Der Kooij
In this paper we presented the mechanical design and evaluation of a low-profile and lightweight exoskeleton that supports the finger extension of stroke patients during daily activities without applying axial forces to the finger. The exoskeleton consists of a flexible structure that is secured to the index finger of the user while the thumb is fixed in an opposed position. Pulling on a cable will extend the flexed index finger joint such that objects can be grasped. The device can achieve a grasp size of at least 7 cm. Technical tests confirmed that the exoskeleton was able to counteract the passive flexion moments corresponding to the index finger of a severely affected stroke patient (with an MCP joint stiffness of k = 0.63Nm/rad), requiring a maximum cable activation force of 58.8N. A feasibility study with stroke patients (n=4) revealed that the body-powered operation of the exoskeleton with the contralateral hand caused a mean increase of 46° in the range of motion of the index finger MCP joint. The patients (n=2) who performed the Box & Block Test were able to grasp and transfer maximally 6 blocks in 60 sec. with exoskeleton, compared to 0 blocks without exoskeleton. Our results showed that the developed exoskeleton has the potential to partially restore hand function of stroke patients with impaired finger extension capabilities. An actuation strategy that does not involve the contralateral hand should be implemented during further development to make the exoskeleton suitable for bimanual daily activities.