22 March 2018 in IEEE Robotics & Automation Magazine
Verified
Journal Article
Open access
CHChristoff Heunis
Christoff Heunis
JSJakub Sikorski
Jakub Sikorski
SMSarthak Misra
Sarthak Misra
Endovascular surgery has gained broad acceptance in the last few years. The current practice of endovascular procedures is limited by factors including patient-specific operation requirements, high-risk surgery procedures, and time-consuming operations. To address this, magnetically actuated surgical catheters have been introduced to the field of surgical robotics. Recently, advances in steerable catheters and developments in magnetic steering have been studied. However, limited research has been conducted to quantify the effectiveness of magnetic actuation for catheterization procedures. Endovascular interventions employing magnetically actuated catheters deliver the promise of higher accuracy and shorter duration when compared to current, manual techniques. Moreover, they allow surgeons access to areas of cardiovascular systems that cannot be reached with standard, minimally invasive techniques.

19 June 2019 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
JSJakub Sikorski
Jakub Sikorski
CHChristoff Heunis
Christoff Heunis
FFFederico Franco
Federico Franco
SMSarthak Misra
Sarthak Misra

9 January 2020 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
CHChristoff Heunis
Christoff Heunis
YWYannik Paul Wotte
Yannik Paul Wotte
JSJakub Sikorski
Jakub Sikorski
GFGuilherme Phillips Furtado
Guilherme Phillips Furtado
SMSarthak Misra
Sarthak Misra
Robot-assisted technologies are increasingly being developed for their use in endovascular surgery. These technologies can aid clinicians in providing higher precision, increased accuracy, and reproducibility. This paper further extends the clinical feasibility of an autonomous system designed to provide assistance during endovascular procedures. We develop a control strategy that allows a user to guide a magnetic catheter to target sites. The system handles the full synchronization of co-operating manipulators that both actuate a clinical tool. The catheter is positioned using magnetic actuation and proportional-integral (PI) control in conjunction with real-time ultrasound images. Our results indicate an average error between the tracked catheter tip and target positions of 2.09±0.49 mm. We expect that our system will provide a step towards collaborative manipulators employing mobile electromagnets, and possibly improve autonomous catheterization procedures within endovascular surgeries.

3 May 2021 in IEEE Access
Verified
Journal Article
Open access
Filip ŠuligojFilip Šuligoj
Filip Šuligoj
CHChristoff Heunis
Christoff Heunis
JSJakub Sikorski
Jakub Sikorski
SMSarthak Misra
Sarthak Misra
Medical ultrasound (US) systems are widely used for the diagnosis of internal tissues. However, there are challenges associated with acquiring and interpreting US images, such as incorrect US probe placement and limited available spatial information. In this study, we expand the capabilities of medical US imaging using a robotic framework with a high level of autonomy. A 3D camera is used to capture the surface of an anthropomorphic phantom as a point cloud, which is then used for path planning and navigation of the US probe. Robotic positioning of the probe is realised using an impedance controller, which maintains stable contact with the surface during US scanning and compensates for uneven and moving surfaces. Robotic US positioning accuracy is measured to be 1.19± 0.76mm. The mean force along US probe z-direction is measured to be 6.11±1.18N on static surfaces and 6.63±2.18N on moving surfaces. Overall lowest measured force of 1.58N demonstrates constant probe-to-surface contact during scanning. Acquired US images are used for the 3D reconstruction and multi-modal visualization of the surface and the inner anatomical structures of the phantom. Finally, K-means clustering is used to segment different tissues. Best segmentation accuracy of the jugular vein according to Jaccard similarity coefficient is measured to be 0.89. With such an accuracy, this system could substantially improve autonomous US acquisition and enhance the diagnostic confidence of clinicians.

19 November 2021 in IEEE Transactions on Robotics
Verified
Journal Article
Open access
JSJakub Sikorski
Jakub Sikorski
CHChristoff Heunis
Christoff Heunis
RORafic Obeid
Rafic Obeid
VVVenkatasubramanian Kalpathy Venkiteswaran
Venkatasubramanian Kalpathy Venkiteswaran
SMSarthak Misra
Sarthak Misra
Magnetic actuation is a versatiletechnology, widely applied in medical robotics for noncontact steering of flexible instruments and untethered agents. In this article, we exploit the benefits of this technology by developing a magnetically actuated flexible catheter capable of the controlled ejection and retrieval of an untethered magnetic capsule. The catheter is actuated by the advanced robotics for magnetic manipulation system. The scanning ultrasound is used for 3-D shape reconstruction of the catheter, with a mean error of 0.37 mm. We use a closed-loop position controller to steer the catheter, reporting a mean error of 0.82 mm. We develop a dynamic model of the capsule and use it to predict the trajectory of the projectile. We demonstrate the targeting of the capsule utilizing the null-space of the catheter actuation (mean residual tip displacement of 0.8 mm). Finally, we perform a delivery of a capsule to and retrieval from a target inaccessible for the catheter tip, demonstrating the capability of our instrument to reach challenging locations.

28 June 2021 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
CHChristoff Heunis
Christoff Heunis
KBKasper J. Behrendt
Kasper J. Behrendt
EHEdsko Hekman
Edsko Hekman
CMCyril Moers
Cyril Moers
JVJean-Paul P.M. de Vries
Jean-Paul P.M. de Vries
SMSarthak Misra
Sarthak Misra
Arterial stenosis is a high-risk disease accompanied by large amounts of calcified deposits and plaques that develop inside the vasculature. These deposits should be reduced to improve blood flow. However, current methods used to reduce stenosis require externally controlled actuation systems resulting in limited workspace or patient risks. This results in an unexplored preference regarding the revascularization strategy for symptomatic artery stenosis. In this article, we propose a novel internally actuated solution: a magnetic spring-loaded rotablation catheter. The catheter is developed to achieve stenosis-debulking capabilities by actuating drill bits using two internal electromagnetic coils and a magnetic reciprocating spring-loaded shaft. The state-space model of the catheter is validated by comparing the simulation results of the magnetic fields of the internal coils with the experimental results of a fabricated prototype. Contact forces of the catheter tip are measured experimentally, resulting in a maximum axial force of 2.63 N and a torque of 5.69 mN-m. Finally, we present interventions in which the catheter is inserted to reach a vascular target site and demonstrate plaque-specific treatment using different detachable actuator bits. Calcified deposits are debulked and visualized via ultrasound imaging. The catheter can reduce a stenosis cross-sectional area by up to 35%, indicating the potential for the treatment of calcified lesions, which could prevent restenosis.