Aims: Periprosthetic fracture and implant loosening are two of the major reasons for revision surgery of cementless implants. Optimal implant fixation with minimal bone damage is challenging in this procedure. This pilot study investigates whether vibratory implant insertion is gentler compared to consecutive single blows for acetabular component implantation in a surrogate polyurethane (PU) model.Methods: Acetabular components (cups) were implanted into 1 mm nominal under-sized cavities in PU foams (15 and 30 per cubic foot (PCF)) using a vibratory implant insertion device and an automated impaction device for single blows. The impaction force, remaining polar gap, and lever-out moment were measured and compared between the impaction methods.Results: Impaction force was reduced by 89% and 53% for vibratory insertion in 15 and 30 PCF foams, respectively. Both methods positioned the component with polar gaps under 2 mm in 15 PCF foam. However, in 30 PCF foam, the vibratory insertion resulted in a clinically undesirable polar gap of over 2 mm. A higher lever-out moment was achieved with the consecutive single blow insertion by 42% in 15 PCF and 2.7 times higher in 30 PCF foam.Conclusion: Vibratory implant insertion may lower periprosthetic fracture risk by reducing impaction forces, particularly in low-quality bone. Achieving implant seating using vibratory insertion requires adjustment of the nominal press-fit, especially in denser bone. Further preclinical testing on real bone tissue is necessary to assess whether its viscoelasticity in combination with an adjusted press-fit can compensate for the reduced primary stability after vibratory insertion observed in this study.Cite this article: Bone Joint Res 2024;13(6):272–278.

7 April 2025 in Bone & Joint Research
Verified
Journal Article
Open access
PDF file
YNYasaman Niki
Yasaman Niki
GHGerd Huber
Gerd Huber
KBKambiz Behzadi
Kambiz Behzadi
MMMichael Morlock
Michael Morlock
Aims: Sufficient primary implant stability with minimal bone damage is one of the challenges for uncemented implant fixation to prevent periprosthetic fractures and implant loosening. A pilot study on a non-viscoelastic material (polyurethane foam) showed a reduced impaction force when using vibratory implant insertion. This study assessed the effectiveness of vibratory implant insertion compared to an established implant insertion method in physiological viscoelastic bone from porcine hips.Methods: Acetabular components were impacted line-to-line and into 1 mm nominal undersized cavities in porcine acetabula (n = 24 in total, n = 6 acetabula per group of study) using vibration (60 Hz) and 1 Hz (established) impaction methods. The impaction force, remaining polar gap, and lever-out moment were measured and compared between the impaction methods and different press-fits.Results: The vibratory impaction method produced almost 40% lower impaction forces at both press-fit levels. However, complete seating at the nominal press-fit of 1 mm was not achieved, and primary stability was lower for the vibratory impaction for either press-fit.Conclusion: Bone fracture risk due to high impaction forces could be reduced by vibrational implant insertion at the cost of a reduction in primary stability. The outcome of the vibratory impaction method in porcine bone was similar to a previous study using polyurethane foams, suggesting that the viscoelasticity of bone may not play a crucial role during press-fit implant impaction.Cite this article: Bone Joint Res 2025;14(4):306–314.