Industrial workplaces expose workers to a high risk of injuries such as Work-related Musculoskeletal Disorders (WMSDs). Exoskeletons are wearable robotic technologies that can be used to reduce the loads exerted on the body’s joints and reduce the occurrence of WMSDs. However, current studies show that the deployment of industrial exoskeletons is still limited, and widespread adoption depends on different factors, including efficacy evaluation metrics, target tasks, and supported body postures. Given that exoskeletons are not yet adopted to their full potential, we propose a review based on these three evaluation dimensions that guides researchers and practitioners in properly evaluating and selecting exoskeletons and using them effectively in workplaces. Specifically, evaluating an exoskeleton needs to incorporate: (1) efficacy evaluation metrics based on both subjective (e.g., user perception) and objective (e.g., physiological measurements from sensors) measures, (2) target tasks (e.g., manual material handling and the use of tools), and (3) the body postures adopted (e.g., squatting and stooping). This framework is meant to guide the implementation and assessment of exoskeletons and provide recommendations addressing potential challenges in the adoption of industrial exoskeletons. The ultimate goal is to use the framework to enhance the acceptance and adoption of exoskeletons and to minimize future WMSDs in industrial workplaces.
Workers in the construction industry are frequently exposed to physically demanding manual tasks with a high level of ergonomic risk. To prevent ergonomic injuries and disorders, posture-based ergonomic evaluation methods, which require inputs describing the worker’s posture (e.g., body joint angles), have been developed and are used widely in practice. However, the reliability of these ergonomic methods has not been investigated fully from the input measurement perspective, as when collected by a human observer or motion capture sensors, and which may inevitably contain measurement errors (e.g., human perception errors and sensing errors in estimating human postures). Thus, this study examines the imprecision associated with acquiring the required inputs for ergonomic assessment and investigates its impact on the final result of the analysis. The two primary methods of obtaining the inputs of posture-based evaluation tools, i.e., human observation and recordings of motion sensing devices, were examined, and a stochastic approach was proposed to evaluate the impact of the input errors on the final result of the ergonomic assessment. The findings indicate that the imprecision associated with inputs from both visual observers and sensors have significant impact on the results of ergonomic analysis and should be incorporated into the analysis accordingly. The contribution of this paper allows practitioners and researchers to understand possible ranges of outputs that can be caused by observation and measurement errors, and to determine allowable tolerance of sensing errors required for ergonomic evaluation through stochastic analysis.
24 December 2024 in Biomedical Signal Processing and Control