Shangkun Liu

Ms. Shangkun Liu

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2023 in Expert Systems with Applications
Verified
Journal Article
Closed access
NLNing Liu
Ning Liu
SLShangkun Liu
Shangkun Liu
QCQingwei Chai
Qingwei Chai
WZWeimin Zheng
Weimin Zheng

18 September 2023 in Entropy
Verified
Journal Article
Open access
PDF file
SGShi-Cheng Guo
Shi-Cheng Guo
SLShangkun Liu
Shangkun Liu
JWJing-Yu Wang
Jing-Yu Wang
WZWeimin Zheng
Weimin Zheng
CJCheng-Yu Jiang
Cheng-Yu Jiang
Recent research has shown that visual–text pretrained models perform well in traditional vision tasks. CLIP, as the most influential work, has garnered significant attention from researchers. Thanks to its excellent visual representation capabilities, many recent studies have used CLIP for pixel-level tasks. We explore the potential abilities of CLIP in the field of few-shot segmentation. The current mainstream approach is to utilize support and query features to generate class prototypes and then use the prototype features to match image features. We propose a new method that utilizes CLIP to extract text features for a specific class. These text features are then used as training samples to participate in the model’s training process. The addition of text features enables model to extract features that contain richer semantic information, thus making it easier to capture potential class information. To better match the query image features, we also propose a new prototype generation method that incorporates multi-modal fusion features of text and images in the prototype generation process. Adaptive query prototypes were generated by combining foreground and background information from the images with the multi-modal support prototype, thereby allowing for a better matching of image features and improved segmentation accuracy. We provide a new perspective to the task of few-shot segmentation in multi-modal scenarios. Experiments demonstrate that our proposed method achieves excellent results on two common datasets, PASCAL-5i and COCO-20i.

4 October 2023 in Expert Systems with Applications
Verified
Journal Article
Closed access
SLShangkun Liu
Shangkun Liu
YLYanxin Li
Yanxin Li
QCQingwei Chai
Qingwei Chai
WZWeimin Zheng
Weimin Zheng

9 February 2021 in Ultrasonic Imaging
Verified
Journal Article
Closed access
PDF file
WZWeimin Zheng
Weimin Zheng
SLShangkun Liu
Shangkun Liu
QCQing-Wei Chai
Qing-Wei Chai
Jeng-Shyang PanJeng-Shyang Pan
Jeng-Shyang Pan
SCShu-Chuan Chu
Shu-Chuan Chu
In this study, an automatic pennation angle measuring approach based on deep learning is proposed. Firstly, the Local Radon Transform (LRT) is used to detect the superficial and deep aponeuroses on the ultrasound image. Secondly, a reference line are introduced between the deep and superficial aponeuroses to assist the detection of the orientation of muscle fibers. The Deep Residual Networks (Resnets) are used to judge the relative orientation of the reference line and muscle fibers. Then, reference line is revised until the line is parallel to the orientation of the muscle fibers. Finally, the pennation angle is obtained according to the direction of the detected aponeuroses and the muscle fibers. The angle detected by our proposed method differs by about 1° from the angle manually labeled. With a CPU, the average inference time for a single image of the muscle fibers with the proposed method is around 1.6 s, compared to 0.47 s for one of the image of a sequential image sequence. Experimental results show that the proposed method can achieve accurate and robust measurements of pennation angle.

1 January 2022 in Wireless Communications and Mobile Computing
Verified
Journal Article
Open access
PDF file
NLNing Liu
Ning Liu
QCQingwei Chai
Qingwei Chai
SLShangkun Liu
Shangkun Liu
WZWeimin Zheng
Weimin Zheng
The problem of 3D coverage in a wireless sensor network (WSN) has always been an urgent problem to be solved. A novel compact particle swarm optimization algorithm (ncPSO) to solve this problem is proposed in this paper. This algorithm uses a Pareto distribution to describe the position of particle swarms. The ncPSO reduces memory usage compared to traditional heuristics. The ncPSO using the Pareto distribution is less likely to fall into local optima than other compact algorithms using the Gaussian distribution. We also add Gaussian perturbation strategy to the algorithm to better avoid the algorithm falling into local optimum. Among the test functions of CEC2013, the ncPSO achieves remarkable optimization ability on most test functions. Finally, we apply ncPSO to the 3D coverage problem of sensors. Compared with other algorithms, the ncPSO achieves satisfactory results.

30 March 2022 in Electronics
Verified
Journal Article
Open access
PDF file
WZWeimin Zheng
Weimin Zheng
LZLinxueying Zhou
Linxueying Zhou
QCQingwei Chai
Qingwei Chai
JXJianguo Xu
Jianguo Xu
SLShangkun Liu
Shangkun Liu
The parameters of muscle ultrasound images reflect the function and state of muscles. They are of great significance to the diagnosis of muscle diseases. Because manual labeling is time-consuming and laborious, the automatic labeling of muscle ultrasound image parameters has become a research topic. In recent years, there have been many methods that apply image processing and deep learning to automatically analyze muscle ultrasound images. However, these methods have limitations, such as being non-automatic, not applicable to images with complex noise, and only being able to measure a single parameter. This paper proposes a fully automatic muscle ultrasound image analysis method based on image segmentation to solve these problems. This method is based on the Deep Residual Shrinkage U-Net(RS-Unet) to accurately segment ultrasound images. Compared with the existing methods, the accuracy of our method shows a great improvement. The mean differences of pennation angle, fascicle length and muscle thickness are about 0.09°, 0.4 mm and 0.63 mm, respectively. Experimental results show that the proposed method realizes the accurate measurement of muscle parameters and exhibits stability and robustness.