Xianbo Qiu

Prof. Xianbo Qiu

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2010 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
DCDafeng Chen
Dafeng Chen
MMMichael Mauk
Michael Mauk
XQXianbo Qiu
Xianbo Qiu
CLChangchun Liu
Changchun Liu
JKJitae Kim
Jitae Kim
HBHaim H Bau
Haim H Bau

1 April 2011 in The Analyst
Verified
Journal Article
Closed access
PDF file
CLChangchun Liu
Changchun Liu
EGEran Geva
Eran Geva
MMMichael Mauk
Michael Mauk
XQXianbo Qiu
Xianbo Qiu
WAWilliam R. Abrams
William R. Abrams
HBHaim H Bau
Haim H Bau
A simple, point of care, inexpensive, disposable cassette for the detection of nucleic acids extracted from pathogens was designed, constructed, and tested. The cassette utilizes a single reaction chamber for isothermal amplification of nucleic acids. The chamber is equipped with an integrated, flow-through, Flinders Technology Associates (Whatman FTA®) membrane for the isolation, concentration, and purification of DNA and/or RNA. The nucleic acids captured by the membrane are used directly as templates for amplification without elution, thus simplifying the cassette's flow control. The FTA membrane also serves another critical role—enabling the removal of inhibitors that dramatically reduce detection sensitivity. Thermal control is provided with a thin film heater external to the cassette. The amplification process was monitored in real time with a portable, compact fluorescent reader. The utility of the integrated, single-chamber cassette was demonstrated by detecting the presence of HIV-1 in oral fluids. The HIV RNA was reverse transcribed and subjected to loop-mediated, isothermal amplification (LAMP). A detection limit of less than 10 HIV particles was demonstrated. The cassette is particularly suitable for resource poor regions, where funds and trained personnel are in short supply. The cassette can be readily modified to detect nucleic acids associated with other pathogens borne in saliva, urine, and other body fluids as well as in water and food.

21 August 2019 in Nanotechnology
Verified
Journal Article
Closed access
PWPeiqi Wei
Peiqi Wei
XGXiao-Liang Guo
Xiao-Liang Guo
XQXianbo Qiu
Xianbo Qiu
DYDuli Yu
Duli Yu
In recent years, the development of electronic skin and smart wearable body sensors has put forward high requirements for flexible pressure sensors with high sensitivity and large linear measuring range. However, it turns out to be difficult to increase both of them simultaneously. In this paper, a flexible capacitive pressure sensor based on a porous carbon conductive paste-polydimethylsiloxane composite is reported, the sensitivity and the linear measuring range of which were developed using multiple methods including adjusting the stiffness of the dielectric layer material, fabricating a microstructure and increasing the dielectric permittivity of the dielectric layer. The capacitive pressure sensor reported here has a relatively high sensitivity of 1.1 kPa −1 and a large linear measuring range of 10 kPa, making the product of the sensitivity and linear measuring range 11, which is higher than that of the most reported capacitive pressure sensors to our best knowledge. The sensor has a detection of limit of 4 Pa, response time of 60 ms and great stability. Some potential applications of the sensor were demonstrated, such as arterial pulse wave measuring and breath measuring, which shows it as a promising candidate for wearable biomedical devices. In addition, a pressure sensor array based on the material was also fabricated and it could identify objects in the shape of different letters clearly, which shows promising application in future electronic skins.

6 July 2011 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
CLChangchun Liu
Changchun Liu
MMMichael G. Mauk
Michael G. Mauk
RHRobert Hart
Robert Hart
XQXianbo Qiu
Xianbo Qiu
HBHaim H Bau
Haim H Bau
A disposable, water-activated, self-heating, easy-to-use, polymeric cartridge for isothermal nucleic acid amplification and visual fluorescent detection of the amplification products is described. The device is self-contained and does not require any special instruments to operate. The cartridge integrates chemical, water-triggered, exothermic heating with temperature regulation facilitated with a phase-change material (PCM) and isothermal nucleic acid amplification. The water flows into the exothermic reactor by wicking through a porous paper. The porous paper's characteristics control the rate of water supply, which in turn controls the rate of exothermic reaction. The PCM material enables the cartridge to maintain a desired temperature independent of ambient temperatures in the range between 20 °C and 40 °C. The utility of the cartridge is demonstrated by amplifying and detecting Escherichia coli DNA with loop mediated isothermal amplification (LAMP). The device can detect consistently as few as 10 target molecules in the sample. With proper modifications, the cartridge also can work with other isothermal nucleic acid amplification technologies for detecting nucleic acids associated with various pathogens borne in blood, saliva, urine, and other body fluids as well as in water and food. The device is suitable for use at home, in the field, and in poor-resource settings, where access to sophisticated laboratories is impractical, unaffordable, or nonexistent.

5 December 2008 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
CLChangchun Liu
Changchun Liu
XQXianbo Qiu
Xianbo Qiu
SOSerge Ongagna
Serge Ongagna
DCDafeng Chen
Dafeng Chen
ZCZongyuan Chen
Zongyuan Chen
HBHaim H. Bau
Haim H. Bau
An inexpensive, hand-held, point-of-care, disposable, self-contained immunoassay cassette comprised of air pouches for pumping, a metering chamber, reagents storage chambers, a mixer, and a lateral flow strip was designed, constructed, and tested. The assay was carried out in a consecutive flow format. The detection was facilitated with up-converting phosphor (UCP) reporter particles. The automated, timely pumping of the various reagents was driven by a spring-loaded timer. The utility of the cassette was demonstrated by detecting antibodies to HIV in saliva samples and further evaluated with a non-contagious, haptenized DNA assay. The cassette has several advantages over dip sticks such as sample preprocessing, integrated storage of reagents, and automated operation that reduces operator errors and training. The cassette and actuator described herein can readily be extended to detect biomarkers of other diseases in body fluids and other fluids at the point of care. The system is particularly suitable for resource-poor countries, where funds and trained personnel are in short supply.

14 July 2009 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
XQXianbo Qiu
Xianbo Qiu
JTJason A. Thompson
Jason A. Thompson
ZCZongyuan Chen
Zongyuan Chen
CLChangchun Liu
Changchun Liu
DCDafeng Chen
Dafeng Chen
HBHaim H Bau
Haim H Bau