Xiao-Liang Guo

Prof. Xiao-Liang Guo


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2019 in Nanotechnology
Verified
Journal Article
Closed access
PWPeiqi Wei
Peiqi Wei
XGXiao-Liang Guo
Xiao-Liang Guo
XQXianbo Qiu
Xianbo Qiu
DYDuli Yu
Duli Yu
In recent years, the development of electronic skin and smart wearable body sensors has put forward high requirements for flexible pressure sensors with high sensitivity and large linear measuring range. However, it turns out to be difficult to increase both of them simultaneously. In this paper, a flexible capacitive pressure sensor based on a porous carbon conductive paste-polydimethylsiloxane composite is reported, the sensitivity and the linear measuring range of which were developed using multiple methods including adjusting the stiffness of the dielectric layer material, fabricating a microstructure and increasing the dielectric permittivity of the dielectric layer. The capacitive pressure sensor reported here has a relatively high sensitivity of 1.1 kPa −1 and a large linear measuring range of 10 kPa, making the product of the sensitivity and linear measuring range 11, which is higher than that of the most reported capacitive pressure sensors to our best knowledge. The sensor has a detection of limit of 4 Pa, response time of 60 ms and great stability. Some potential applications of the sensor were demonstrated, such as arterial pulse wave measuring and breath measuring, which shows it as a promising candidate for wearable biomedical devices. In addition, a pressure sensor array based on the material was also fabricated and it could identify objects in the shape of different letters clearly, which shows promising application in future electronic skins.

12 July 2019 in Advanced Materials Technologies
Verified
Journal Article
Closed access
PDF file
PWPeiqi Wei
Peiqi Wei
XYXin Yang
Xin Yang
ZCZimei Cao
Zimei Cao
XGXiao-Liang Guo
Xiao-Liang Guo
HJHonglan Jiang
Honglan Jiang
DYDuli Yu
Duli Yu

18 September 2018 in Sensors
Verified
Journal Article
Open access
PDF file
XGXiao-Liang Guo
Xiao-Liang Guo
CYChen Yan
Chen Yan
HJHong-Lan Jiang
Hong-Lan Jiang
XQXianbo Qiu
Xianbo Qiu
DYDu-Li Yu
Du-Li Yu
Formaldehyde is one of the most dangerous air pollutants, which can cause sick building syndrome. Thus, it is very crucial to precisely determine formaldehyde with a low cost and simple operation. In this paper, a smartphone-based microfluidic colorimetric sensor is devised for gaseous formaldehyde determination with high sensitivity and selectivity. Specifically, a novel microfluidic chip is proposed based on the 4-aminohydrazine-5-mercapto-1,2,4-triazole (AHMT) method to determine formaldehyde; the chip consists of two reagent reservoirs, one reaction reservoir and a mixing column. In this design to prevent the fluid from flowing out while letting the gas molecule in, a hydrophobic porous poly tetra fluoroethylene (PTFE) membrane is put on the top of the reaction reservoir. Using the microfluidic chip sensor, a smartphone-based formaldehyde determination system is developed, which makes the measuring process automated and simple. As per the experiment results, the limit-of-detection (LOD) of the system is as low as 0.01 ppm, which is much lower than the maximum exposure concentration (0.08 ppm) recommended by the World Health Organization (WHO). Moreover, the sensor is hardly affected by acetaldehyde, volatile organic compounds (VOCs) or acidic-alkaline, which shows great selectivity. Finally, the performance of the proposed sensor is verified by using it for the determination of formaldehyde in a newly decorated house.

10 August 2016 in Scientific Reports
Verified
Journal Article
Open access
XGXiao-Liang Guo
Xiao-Liang Guo
RZRONG ZHU
RONG ZHU
This paper reports a novel microarray chip for in-situ, real-time and selective electroporation on individual cells integrated with cell positioning and impedance monitoring. An array of quadrupole-electrode units (termed positioning electrodes) and pairs of planar center electrodes located at the centers of each quadrupole-electrode unit were fabricated on the chip. The positioning electrodes are used to trap and position living cells onto the center electrodes based on negative dielectrophoresis (nDEP). The center electrodes are used for in-situ cell electroporation and also used to measure cell impedance for monitoring cellular dynamics in real time. Controllably selective electroporation and electrical measurement on the cells in array are realized. We present an evidence of selective electroporation through use of fluorescent dyes. Subsequently we use in-situ and real-time impedance measurement to monitor the process, which demonstrates the dynamic behavior of the cell electroporation. Finally, we show the use of this device to perform successful transfection onto individual HeLa cells with vector DNA encoding a green fluorescent.


3 August 2015 in The Analyst
Verified
Journal Article
Closed access
PDF file
XGXiao-Liang Guo
Xiao-Liang Guo
RZRong Zhu
Rong Zhu
XZXianli Zong
Xianli Zong
This paper presents a novel microarray chip integrating cell positioning with in situ, real-time and long-time impedance measurement on a single cell. The microchip integrates a plurality of quadrupole-electrode units (termed positioning electrodes) patterned into an array with pairs of planar electrodes (termed measuring electrodes) located at the centers of each quadrupole-electrode unit. The positioning electrodes are utilized to trap and position living cells onto the measuring electrodes based on negative dielectrophoresis (nDEP), while the measuring electrodes are used to measure impedances of the trapped single cells. Each measuring electrode has a small footprint area of 7 × 7 μm2 to ensure inhabiting only one single cell on it. However, the electrode with a small surface area has a low double-layer capacitance when it is immersed in a liquid solution, thus generating a large double-layer impedance, which reduces the sensitivity for impedance measurement on the single cell. To enlarge the effective surface areas of the measuring electrodes, a novel surface-modification process is proposed to controllably construct gold nanostructures on the surfaces of the measuring electrodes while the positioning electrodes are unstained. The double layer capacitances of the modified electrodes are increased by about one order after surface-modification. The developed microchip is used to monitor the adhering behavior of a single HeLa cell by measuring its impedance spectra in real time. The measured impedance is analyzed and used to extract cellular electrical parameters, which demonstrated that the cell compresses the electrical double layer in the process of adherence and adheres onto the measuring electrodes after 4–5 hours.