Ching-Hsiu Ke

Ms. Ching-Hsiu Ke

Central Taiwan University of Science and Technology, Taichung, Taiwan

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 November 2021 in Children
Verified
Journal Article
Open access
PDF file
HKHui-Ying Kuo
Hui-Ying Kuo
Ching-Hsiu KeChing-Hsiu Ke
Ching-Hsiu Ke
SCShyan-Tarng Chen
Shyan-Tarng Chen
HSHan-Ying Sun
Han-Ying Sun
Taiwan is commonly noted for its high prevalence of myopia, as well as a long history of more than 20 years of using atropine to control myopia. However, the clinical implications are rarely discussed. This is a cross-sectional study investigating the influence of topical atropine instillation on ocular physiology, visual function, and visual discomfort in children. Aged 7 to 12 years, 212 schoolchildren were recruited and divided into the atropine group and the non-atropine group. Physiological characteristics such as pupil size and intraocular pressure were measured, and a variety of visual functions was also evaluated. A questionnaire was used to investigate the side effects and visual complaints caused by atropine treatment. There was a significant difference in pupil size (OD: 5.40 ± 0.90 vs. 6.60 ± 1.01 mm; OS: 5.42 ± 0.87 vs. 6.64 ± 1.00 mm, p < 0.001) between the two groups. Reductions in near visual acuity, accommodation, convergence ability, and stereopsis were observed in the atropine group. The horizontal pupil diameter enlarged, and visual functions were greatly affected after administration of topical atropine. The changes in visual function during atropine therapy need to be carefully monitored by clinicians, while patient compliance is usually the key to success.

5 March 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Ching-Hsiu KeChing-Hsiu Ke
Ching-Hsiu Ke
WLWan-Ju Liu
Wan-Ju Liu
BPBing-Ru Peng
Bing-Ru Peng
LPLung-Fa Pan
Lung-Fa Pan
Lung-Kwag PanLung-Kwag Pan
Lung-Kwag Pan
This study tried to propose an innovated idea of solidifying the resolution of gamma camera in routine quality control and recommended a quantified index as minimum detectable difference (MDD) of gamma camera SPECT images using the Taguchi analysis and an indigenous V-shaped slit gauge. The gauge was customized to fulfill the quantitative requirement of the Taguchi analysis. The MDD among slit gauge of derived SPECT image was calculated from two overlapped peak profiles collected from a tangent slice of the V-shaped slit gauge with two nearby peaks. In particular, MDD was evaluated as minimum distance between two peak centers through the Student’s t-test with a constant, 1.96, which indicates that two peak centers separated distant enough to create a 95% confidence level of separation. Eighteen combinations of six gamma camera scanned factors were organized according to Taguchi analysis. Accordingly, (A) collimator, (B) detector to targe distance, (C) total counts, (D) acquired energy width, (E) Matrix size, and (F) zoom of collected ROI with each of two or three levels were organized into 18 groups to collect the slit gauge images according to Taguchi L18 orthogonal array. Then, three well-trained radiologists were ranked the scanned gauge images to derive the fish-bone-plot of signal-to-noise ratio (S/N, dB) and correlated ANOVA. Furthermore, the quantified MDD was proposed to verify the optimal suggestion of gamma camera scanned protocol, and obtained the MDD as 8.4, 7.9, and 7.1 mm for the second group of original L18 preset, conventional, and the optimal preset, respectively. Thus, the optimal preset of gamma camera was achieved in this study. The MDD proved to be a successful index in quantifying the imaging resolution of a gamma camera.

25 September 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
YLYa-Hui Lin
Ya-Hui Lin
CLChun-Chieh Liang
Chun-Chieh Liang
YCYing-Liang Chou
Ying-Liang Chou
CLChih-Sheng Lin
Chih-Sheng Lin
KCKelin Chen
Kelin Chen
Ching-Hsiu KeChing-Hsiu Ke
Ching-Hsiu Ke
Objective: This study provided a quantitative prediction of best-corrected visual acuity (BCVA) for cataract patients using the inverse problem algorithm (IPA) technique earlier proposed by the authors. Methods: To this end, seven risk factors (age, BMI, MAP, IOP, HbA1c, LDL-C, and gender) were linked by a semi-empirical formula by normalizing each factor into a dimensionless range of −1.0 to +1.0. The adopted inverse problem algorithm (IPA) technique was run via a self-developed program in STATISTICA 7.0, featuring a 29-term nonlinear equation considering seven risk factors, cross-interaction between various pairs of factors, and one constant term [7 + (7 × 6)/2 + 1 = 29]. The IPA neglected quadratic, triple, or quadruple factors′ cross-interactions. This study used a dataset of 632 cataract patients to attain a reliable BCVA prediction with a variance of 0.929. A verification dataset of 160 patients with similar symptoms was used to verify this approach′s feasibility, reaching a good correlation with R2 = 0.909. Results: The verification group′s derived average AT (agreement) (9.12 ± 27.00%) indicated a slight deviation between the theoretical prediction and practical BCVA. The significant factors were age, body mass index (BMI), and intraocular pressure (IOP), whereas mean arterial pressure (MAP), hemoglobin A1c (HbA1c), low-density-lipoprotein cholesterol (LDL-C), and gender insignificantly contributed to BCVA. Conclusions: The proposed approach is instrumental in AI-assisted clinical diagnosis, yielding robust BCVA predictions for individual cataract patients based on their biological indices before the ophthalmological examination procedure.