Bing-Ru Peng

Dr. Bing-Ru Peng

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 March 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Ching-Hsiu KeChing-Hsiu Ke
Ching-Hsiu Ke
WLWan-Ju Liu
Wan-Ju Liu
BPBing-Ru Peng
Bing-Ru Peng
LPLung-Fa Pan
Lung-Fa Pan
Lung-Kwag PanLung-Kwag Pan
Lung-Kwag Pan
This study tried to propose an innovated idea of solidifying the resolution of gamma camera in routine quality control and recommended a quantified index as minimum detectable difference (MDD) of gamma camera SPECT images using the Taguchi analysis and an indigenous V-shaped slit gauge. The gauge was customized to fulfill the quantitative requirement of the Taguchi analysis. The MDD among slit gauge of derived SPECT image was calculated from two overlapped peak profiles collected from a tangent slice of the V-shaped slit gauge with two nearby peaks. In particular, MDD was evaluated as minimum distance between two peak centers through the Student’s t-test with a constant, 1.96, which indicates that two peak centers separated distant enough to create a 95% confidence level of separation. Eighteen combinations of six gamma camera scanned factors were organized according to Taguchi analysis. Accordingly, (A) collimator, (B) detector to targe distance, (C) total counts, (D) acquired energy width, (E) Matrix size, and (F) zoom of collected ROI with each of two or three levels were organized into 18 groups to collect the slit gauge images according to Taguchi L18 orthogonal array. Then, three well-trained radiologists were ranked the scanned gauge images to derive the fish-bone-plot of signal-to-noise ratio (S/N, dB) and correlated ANOVA. Furthermore, the quantified MDD was proposed to verify the optimal suggestion of gamma camera scanned protocol, and obtained the MDD as 8.4, 7.9, and 7.1 mm for the second group of original L18 preset, conventional, and the optimal preset, respectively. Thus, the optimal preset of gamma camera was achieved in this study. The MDD proved to be a successful index in quantifying the imaging resolution of a gamma camera.

28 September 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KHKai-Yu Hsiao
Kai-Yu Hsiao
CLChih-Sheng Lin
Chih-Sheng Lin
WLWan-Ming Li
Wan-Ming Li
SHShih-Hsun Huang
Shih-Hsun Huang
YCYu-Ting Cho
Yu-Ting Cho
LPLung Fa Pan
Lung Fa Pan
This study optimized the ultrasound image of carotid artery stenosis using Taguchi dynamic analysis and an indigenous water phantom. Eighteen combinations of seven essential factors of the ultrasound scan facility were organized according to Taguchi’s L18 orthogonal array. The seven factors were assigned as follows: (1) angle of probe; (2) signal gain; (3) resolution vs. speed; (4) dynamic range; (5) XRES; (6) zoom; (7) time gain compensation. An indigenous water phantom was customized to satisfy the quantified need in Taguchi’s analysis. Unlike the conventional dynamic Taguchi analysis, an innovative quantified index, the figure of merit (FOM), was proposed to integrate four specific quality characteristics, namely (i) average difference between the practical scan and theoretically preset area (78.5, 50.2 and 12.6 mm2) of stenosis, (ii) standard deviation of the average, (iii) practical scan’s sensitivity β to various stenosis diameters (10, 8, and 4 mm), and (iv) correlation coefficient r2 of the linear regressed sensitivity curve. The highest value (FOM = 0.413) was furnished by the optimal combination of factors on 18 groups under study, yielding high r2 and low β or standard deviation values and the best quality of ultrasound images for the further clinical diagnosis. The comparison between FOM and the conventional signal-to-noise (S/N) ratio in Taguchi’s analysis revealed that FOM compiled more quality characteristics that were superior by nature to fulfill the practical need in clinical diagnosis. The alternative choice in ultrasound scan optimization can be based on stenosis diameter variation from a different perspective to be explored in the follow-up study.

30 May 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LPLung Fa Pan
Lung Fa Pan
CCChao-Yu Chiang
Chao-Yu Chiang
CHChao-Chun Huang
Chao-Chun Huang
HKHUA-Tsan Kao
HUA-Tsan Kao
CCChih-Feng Chen
Chih-Feng Chen
Lung-Kwag PanLung-Kwag Pan
Lung-Kwag Pan
The thyroid biokinetic model of radioactive I-131 was re-evaluated using a refined nine-compartmental model and applied to twelve thyroid cancer patients. In contrast to the simplified four-compartmental model regulated by the ICRP-56 report, the revised model included nine compartments specified in the ICRP-128 report, namely, oral, stomach, body fluid, thyroid, whole body, liver, kidney, bladder, and remainder (i.e., the whole body minus kidney and bladder). A self-developed program run in MATLAB was designed to solve the nine first-order simultaneous linear differential equations. The model was realized in standard and simplified versions. The latter neglected two feedback paths (body fluid to oral, i31, and kidney to the whole body, i87) to reduce computations. Accordingly, the biological half-lives for the major compartments (thyroid and body fluid + whole body) were 36.00 ± 15.01, 15.04 ± 5.63, 34.33 ± 15.42, and 14.83 ± 5.91 of standard and simplified version. The correlations between theoretical and empirical data for each patient were quantified by the dimensionless AT (agreement) index and, the ATtot index integrated each individual AT of a specific organ of one patient. Since small AT values indicated a closer correlation, the obtained range of ATtot (0.048 ± 0.019) proved the standard model’s reliability and high accuracy, while the simplified one yielded slightly higher ATtot (0.058 ± 0.023). The detailed outcomes among various compartments of twelve patients were calculated and compared with other researchers’ work. The correlation results on radioactive I-131 evolution in thyroid cancer patients’ bodies are instrumental in viewpoint of radioactive protection of patients and radiological personnel.

31 October 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
CLChih-Sheng Lin
Chih-Sheng Lin
BPBing-Ru Peng
Bing-Ru Peng
HMHong-Bing Ma
Hong-Bing Ma
KCKelin Chen
Kelin Chen
TLTsung-Han Lin
Tsung-Han Lin
YLYa-Hui Lin
Ya-Hui Lin
This study mitigated the challenge of head and neck CT angiography by IPA-based time-resolved imaging of contrast kinetics. To this end, 627 cerebral hemorrhage patients with dizziness, brain aneurysm, stroke, or hemorrhagic stroke diagnosis were randomly categorized into three groups, namely, the original dataset (450), verification group (112), and in vivo testified group (65), in the Affiliated BenQ Hospital of Nanjing Medical University. In the first stage, seven risk factors were assigned: age, CTA tube voltage, body surface area, heart rate per minute, cardiac output blood per minute, the actual injected amount of contrast media, and CTA delayed trigger timing. The expectation value of the semi-empirical formula was the CTA number of the patient’s left artery (LA). Accordingly, 29 items of the first-order nonlinear equation were calculated via the inverse problem analysis (IPA) technique run in the STATISTICA 7.0 program, yielding a loss function and variance of 3.1837 and 0.8892, respectively. A dimensionless AT was proposed to imply the coincidence, with a lower AT indicating a smaller deviation between theoretical and practical values. The derived formula was confirmed for the verification group of 112 patients, reaching high coincidence, with average ATavg and standard deviation values of 3.57% and 3.06%, respectively. In the second stage, the formula was refined to find the optimal amount of contrast media for the CTA number of LA approaching 400. Finally, the above procedure was applied to head and neck CTA images of the third group of 65 patients, reaching an average CTA number of LA of 407.8 ± 16.2 and finding no significant fluctuations.

31 May 2024 in Technology and Health Care
Verified
Journal Article
Open access
PDF file
CSCheng-Mao Shen
Cheng-Mao Shen
YLYa-Hui Lin
Ya-Hui Lin
DLDian-Fong Li
Dian-Fong Li
LPLung-Kwang Pan
Lung-Kwang Pan
BPBing-Ru Peng
Bing-Ru Peng
BACKGROUND: Cerebral examination via CTA is always the first choice for patients with unexpected brain injury or different types of brain lesions to detect ruptured hemangiomas, vascular infarcts, or other brain tissue lesions. OBJECTIVE: This study innovated the acrylic gauge with five eccentric circles for computed tomography angiography (CTA) analysis to optimize the spatial resolution via Taguchi’s methodology. METHODS: The customized gauge was revised from the V-shaped slit gauge and transferred into five eccentric circles’ slit gauge. The gauge was assembled with another six acrylic layers to simulate the human head. Taguchi’s L18 orthogonal array was adopted to optimize the spatial resolution of CTA imaging quality. In doing so, six essential factors of CTA are kVp, mAs, spiral rotation pitch, FOV, rotation time of the CT and reconstruction filter, and each factor has either two or three levels to organize into eighteen combinations to simulate the full factor combination of 486 (21 × 35 = 486) times according to Taguchi’s recommendation. Three well-trained radiologists ranked the gauge’s 18 CTA scanned imaging qualities according to contrast, sharpness, and spatial resolution and derived the unique fish-bone-plot of six factors for further analysis. The optimal factor combination of CTA was proven by follow-up verification and ANOVA to obtain this study’s dominant or minor factor. RESULTS: The optimal factor combination of CTA was A2 (120 kVp), B3 (200 mAs), C1 (Pitch 0.6), D2 (FOV 220 mm2), E1 (rotation time 0.33 s), and F3 (Brain sharp, UC). Furthermore, deriving a quantified MDD (minimum detectable difference) to imply the spatial resolution of CTA, a semiauto profile analysis program run in MATLAB and OriginPro was recommended to evaluate the MDD and to suppress the manual error in calculation. Eventually, the derived MDDs of the conventional and optimal factor combinations of CTA were 2.35 and 2.26 mm, respectively, in this study. CONCLUSION: Taguchi’s methodology was found applicable for quantifying the CTA imaging quality in practical applications.

24 August 2024 in Journal of Mechanics in Medicine and Biology
Verified
Journal Article
Closed access
YLYa-Hui Lin
Ya-Hui Lin
KCKelin Chen
Kelin Chen
KHKai-Yu Hsiao
Kai-Yu Hsiao
HHHsin-Tzu Huang
Hsin-Tzu Huang
CCChing-Yuan Chen
Ching-Yuan Chen
BPBing-Ru Peng
Bing-Ru Peng