Jinghui Peng

Dr. Jinghui Peng

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
YZYayun Zhang
Yayun Zhang
JPJinghui Peng
Jinghui Peng
RYRui Yang
Rui Yang
YLYuan Lipeng
Yuan Lipeng
Songjing LiSongjing Li
Songjing Li

22 August 2024 in Flow Measurement and Instrumentation
Verified
Journal Article
Closed access
JPJinghui Peng
Jinghui Peng
BSBijan Krishna Saha
Bijan Krishna Saha
SSShah Najmus Shakib
Shah Najmus Shakib
SLSongjing Li
Songjing Li
JJJahidul Islam Jihan
Jahidul Islam Jihan

31 July 2018 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
GFGregory A. Formosa
Gregory A. Formosa
JPJoseph Micah Prendergast
Joseph Micah Prendergast
JPJinghui Peng
Jinghui Peng
DKDonald Kirkpatrick
Donald Kirkpatrick
MRMark E. Rentschler
Mark E. Rentschler
Much of ongoing robotic endoscope research is focused on locomotion, with only limited exploration into feedback control and autonomy in the unconventional and dynamic in vivo environment. This letter presents a modular endoscopy simulation apparatus (MESA) to quickly, affordably, and repeatedly test novel robotic endoscope control schemes in a synthetic colon at an accessible scale. The MESA allows for replication of many common physiologic barriers for current medical robotics, such as disturbances, patient positional changes, angulation of the colon, and a dynamic visual environment. The MESA will allow research teams to quickly and repeatedly validate new control strategies to minimize the effect of these physiological barriers before testing in costly in vivo procedures. The MESA platform and synthetic colon described in this letter have shown successful replication of colon geometry, visual appearance, peristaltic wave speeds and pressures, and disturbances from patient movement. The mold for the synthetic colon was built in sections to allow for geometry changes for future molds and has shown marked similarity to in vivo images from colonoscopies. The actuators chosen for the various controllable stages have proven ample power to produce maximum-case disturbances expected during procedures, and the stages are modular in structure to allow for a variety of testing scenarios. Inflatable rubber tubes and electronic solenoid valves are used to produce contractile forces, and have shown excess capability to reproduce physiological motility. The simulator presented here will aid in future feedback control, localization, and autonomy development for robotic endoscopes.

9 February 2024 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
XLXinbei Lv
Xinbei Lv
JYJunhao Yang
Junhao Yang
QQQingyuan Qi
Qingyuan Qi
JPJinghui Peng
Jinghui Peng
CWChonglei Wang
Chonglei Wang
The self-excited oscillation of an electro-hydraulic servo valve is a crucial factor that affects the operational stability of both the servo valve and the entire servo system. As the intermediary for electromagnetic force, hydraulic force, and feedback force, the dynamic characteristics of the armature assembly play a pivotal role in the emergence of self-excited oscillations. In this article, a mathematical model of the armature assembly is developed using the finite element method (FEM), which establishes a connection between the input signal and the dynamic characteristics of the armature assembly. The structure of the parameter matrix and the recursive relationship of discrete time steps are derived, while the discrete method of the feedback rod and the discrete time format of the FEM model are also analyzed to enhance the prediction accuracy of the model. To validate the efficacy of the FEM model, a numerical simulation model, a classical mathematical model, and an experimental platform are constructed to simulate or measure the dynamic characteristics of the armature assembly. Through the comparison of the dynamic characteristics obtained by the abovementioned methods, it is confirmed that the FEM model effectively predicts both the static and dynamic characteristics of the armature assembly. To suppress the vibration magnitude within the natural frequency range of the armature assembly, the external load that can effectively mitigate the resonance amplitude is calculated based on the FEM model, and the aim of ensuring the stable functionality of the armature assembly throughout its operational range is achieved.

1 April 2025 in Physics of Fluids
Verified
Journal Article
Closed access
YZYayun Zhang
Yayun Zhang
YLYunzhi Liu
Yunzhi Liu
YHYang He
Yang He
JDJianyang Deng
Jianyang Deng
CZChang Zhou
Chang Zhou
Songjing LiSongjing Li
Songjing Li
Cooling channels are typically integrated into high temperature flow regulating valves to mitigate the adverse effects of elevated temperatures on the operation of digital valves and embedded sensors. However, conventional straight cooling channels often suffer from inefficient heat dissipation and excessive pressure losses. In this study, a novel high temperature flow regulating valve incorporating 12 Tesla cooling channels is proposed to simultaneously optimize heat transfer enhancement and flow resistance reduction. Three-dimensional steady-state numerical simulations, based on the Navier–Stokes equations (Laminar flow model), were conducted to analyze the pressure, temperature, Colburn factor (j), and friction factor (f). The Colburn factor (j) was determined from the relationship between heat absorption, surface temperature difference, heat transfer area, and mass velocity of the fluid, while the friction factor (f) was derived from the correlation between the inlet-outlet pressure difference, hydraulic diameter, and mass velocity of the fluid. Numerical results reveal that the mixed cooling capacity of the Tesla structure improves with increasing inlet pressure. Among the 12 schemes, Scheme 1 exhibited the highest heat transfer enhancement with the maximum Colburn factor (j) of 0.173, while Scheme 5 demonstrated the best flow performance with the lowest friction factor (f) of 1.357. Experimental validation confirmed close agreement between the experimental data and numerical results, with discrepancies within 8.83% for j and 6.39% for f. Through analysis of the JF impactor factor, which evaluates the combined performance of heat transfer and flow, the high temperature flow regulating valve with Scheme 11 Tesla cooling channels achieved optimal overall performance, enhancing heat transfer capacity by up to 28.7% and reducing maximum pressure losses by 17.9%. This study provides valuable insight for the design of the valve, enhancing their thermal management and operational efficiency.

13 April 2023 in Energies
Verified
Journal Article
Open access
PDF file
JPJinghui Peng
Jinghui Peng
YZYayun Zhang
Yayun Zhang
Songjing LiSongjing Li
Songjing Li
WBWen Bao
Wen Bao
YTYutaka Tanaka
Yutaka Tanaka
The high-frequency vibration and resonance of armature assembly in the hydraulic servo valve are the main reasons for instability and failure. Magnetic fluid (MF) operating in the squeeze mode can be taken as an effective damper for resonance suppression in the servo valve. Due to excitation difficulty and the low signal-to-noise ratio of high-frequency vibration signals, the capability of MF to modify multiple-order modal damping ratios in a multi-degree-of-freedom system is still unclear. To reveal the mechanism of magnetic fluid for improving modal damping ratios, an algorithm for modal damping ratio identification is proposed. The modal damping ratios of the armature assembly with and without magnetic fluid are identified based on the tested resonance free decay responses. Four resonance frequencies of armature assembly are observed, and the corresponding damping ratios are identified. The equivalent modal damping ratios due to squeeze flow of MF are obtained. The results show that the proposed algorithm can identify damping ratios with an accuracy of up to 98.79%. The damping ratios are improved by double or more due to the magnetic fluid, and the maximum resonance amplitudes are significantly reduced by 65.2% (from 916.5 μm to 318.6 μm).