Jamal  Nasir

Mr. Jamal Nasir

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 June 2021 in IEEE Access
Verified
Journal Article
Open access
MUMuhammad Usman
Muhammad Usman
EKEnis Kobal
Enis Kobal
JNJamal Nasir
Jamal Nasir
YZYuanwei Zhu
Yuanwei Zhu
CYChao Yu
Chao Yu
AZAnding Zhu
Anding Zhu
In this article, a compact dual-port single element MIMO antenna is presented for millimeter wave (mmWave) 5G wireless applications. The presented antenna design consists of an annular ring slot that is fed by a Substrate Integrated Waveguide (SIW) at the two opposite sides of the substrate. The antenna resonates at 28GHz and its 10dB impedance bandwidth is 400MHz. The isolation between the ports is reduced by introducing additional annular slot that acts as a cavity which results in an isolation better than 20dB at 28GHz. The measured gain of both ports are 6.9 dBi which is the highest gain per unit element at 28GHz in the literature. The measured diversity gain and envelope correlation coefficient are 9.98dB and 0.065, respectively, at the band of interest. The measured and simulated results are in good agreement.

15 February 2023 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
SSSyed Manaf Ali Shah
Syed Manaf Ali Shah
MZMuhammad Zada
Muhammad Zada
JNJamal Nasir
Jamal Nasir
OOOwais Owais
Owais Owais
AIAmjad Iqbal
Amjad Iqbal
HYHyoungsuk Yoo
Hyoungsuk Yoo
This study proposes a miniaturized four-port multiple-input-multiple-output (MIMO) implantable antenna for wireless capsule endoscopy (WCE). The proposed MIMO implantable antenna operates in the 2.45 GHz industrial, scientific, and medical (ISM) band, has a compact size of 6.2 × 5.2 × 0.127 mm 3 , and comprises four meandered resonators sharing a common slotless ground plane with an acceptable bandwidth (14.2%) and low mutual coupling. These features help the antenna achieve high data rates and countering multipath distortions, as confirmed using MIMO channel parameters. The calculated link budget analysis of the proposed antenna suggests that seamless high-rate (78 Mbps) information transmission can be efficiently achieved over a distance of up to 10 m (when placed in the large intestine). The proposed MIMO implantable antenna was optimized by placing it inside a capsule comprising sensors, batteries, and electronic components, and was subsequently fabricated. The simulated (S-parameters, gain, and radiation patterns) and measured (in the minced pork) results were in close agreement with a measured bandwidth of 350 MHz and a peak measured gain of -20.1 dBi. To ensure patient safety, the specific absorption rate (SAR) was evaluated for all four ports in different environments (stomach and small and large intestines), and satisfactory results were obtained. MIMO performance parameters, such as the envelope correlation coefficient (ECC), diversity gain (DG), and channel capacity (CC) were also evaluated and acceptable values were noted. To the best of our knowledge, this is the most compact 4-element implantable MIMO antenna designed so far for biomedical applications.

30 May 2022 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
SSSyed Manaf Ali Shah
Syed Manaf Ali Shah
MZMuhammad Zada
Muhammad Zada
JNJamal Nasir
Jamal Nasir
OWOwais
Owais
HYHyoungsuk Yoo
Hyoungsuk Yoo
In this study, an ultraminiaturized implantable antenna is developed for biotelemetry applications. It has triple-band characteristics in the industrial, scientific, and medical (ISM) bands of 902–928 MHz for data telemetry and 2400–2483.5 MHz for power-saving applications and midfield band (1824–1980 MHz) for wireless power transfer simultaneously. The size of the proposed antenna is 0.068 $\lambda _{g}\,\,\times0.048\,\,\lambda _{g}\,\,\times0.0036\,\,\lambda _{g}$ and it is the smallest size of any triple-band implantable antenna ever devised without using shortening vias. Such a compact size is achieved by meandering the shape of the radiating patch and adding open-ended ground slots. Unlike most miniaturized implantable antennas reported in the available literature, no shortening pin is used and this makes the fabrication of the antenna very easy. The bandwidths measured in minced pork muscles are 14% and 24% in the lower and upper ISM bands, respectively, and 12% in the midfield band. The maximum values of the realized gain of the proposed antenna obtained in the heterogeneous skin phantom at 915, 1900, and 2450 MHz are −27.2, −22.2, and −19.9 dBi, respectively. In addition, specific absorption rates (SARs) in the heterogeneous skin and muscle tissues at the three resonance frequencies are calculated and show compliance with the IEEE standards for ensuring human safety. Finally, the range of the biotelemetry link is evaluated by calculating the wireless communication link budget at data rates of 7 kb/s, 100 kb/s, and 10 Mb/s at resonance frequencies.

2 October 2023 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
MZMuhammad Zada
Muhammad Zada
ISIzaz Ali Shah
Izaz Ali Shah
JNJamal Nasir
Jamal Nasir
ABAbdul Basir
Abdul Basir
HYHyoungsuk Yoo
Hyoungsuk Yoo
Remote patient monitoring can improve healthcare outcomes by enabling patients to receive continuous care at home. However, a reliable and convenient means of wireless communication and power transfer is needed to drive implantable biomedical devices. In this study, a complete wireless power transfer (WPT) system and data transmission for remote patient health monitoring is proposed, comprising an implantable receiver (Rx) antenna, an efficient rectifier integrated with the Rx, and a transmitter (Tx) antenna. The implantable Rx antenna has small footprints with dimensions π × 5 2 × 0.75 (58.9 mm 3 ) and exhibits dual-band characteristics: 915 and 2450 MHz for simultaneous wireless power reception and data transmission, respectively. The rectifier of a similar size to the antenna was optimized to operate at 915 MHz with an RF-DC conversion efficiency of 82%. The individual components of the WPT system were simulated, optimized, fabricated, and measured for scattering parameters and gain in a saline-filled 3-D head phantom and minced pork. The implantable antenna and rectifier were then integrated to form a compact rectenna system. A demonstration is performed in the realistic scenario to determine the power reception capability of the proposed implantable rectenna system. For safety purposes, specific absorption rate (SAR) and temperature analysis were conducted and found to be within acceptable limits. Finally, to verify the reliability of the communication link with an external unit, the received power was measured, and the implantable Rx element was found to be capable of effectively communicating over distances of up to 2 m. Our results suggest that this technology has the potential to greatly improve the adoption and effectiveness of remote patient health monitoring, by providing a convenient and reliable means of wireless communication and power transfer.

25 September 2023 in IEEE Access
Verified
Journal Article
Open access
MZMuhammad Zada
Muhammad Zada
JNJamal Nasir
Jamal Nasir
SSSyed Manaf Ali Shah
Syed Manaf Ali Shah
emilio arnieriemilio arnieri
emilio arnieri
HYHyoungsuk Yoo
Hyoungsuk Yoo
The demand for wireless communication in biomedical applications is increasing, thereby necessitating the development of reliable and efficient communication systems that can operate within the human body. This study introduces a novel dual-band two-port multiple-input multiple-output (MIMO) implantable antenna for deep tissue purposes with an overall size of 10.8 × 5.6 × 0.254 mm 3 = 15.3 mm 3 . The proposed MIMO antenna operates in the 915 and 2450 MHz industrial scientific medical bands with a measured bandwidth of 82.5, 148.5 MHz (port 1) and 130, 89 MHz (port 2), in addition peak realized gains of -32.15 and -22.2 dBi, respectively, are observed. High-measured port isolation (over 20 dB and 30 dB at 915 and 2450 MHz bands, respectively) was accomplished by means of meandered resonators. The determined specific absorption rate was within the safe limits. The MIMO performance factors, for instance, the envelope correlation coefficient and diversity gain, were also evaluated and determined to be in the acceptable range. According to our knowledge, this is the first dual-band implantable MIMO antenna developed for biomedical applications. The results from the simulations and measurements indicate that the developed antenna holds great promise for enabling effective communication within the human body for biomedical applications.

1 January 2018 in Wireless Communications and Mobile Computing
Verified
Journal Article
Open access
PDF file
HAHaitham Alsaif
Haitham Alsaif
MUMuhammad Usman
Muhammad Usman
MCMuhammad Tajammal Chughtai
Muhammad Tajammal Chughtai
JNJamal Nasir
Jamal Nasir
This paper presents a novel compact 2 × 2 planar MIMO antenna system with ultra‐wide band capability. Antenna system is specifically designed to target lower 5th generation operating bands ranging from 2 GHz to 12 GHz. This band also covers the IEEE 802.11 a/b/g/n/ac. The antenna array geometry has been simulated using CST MWS. The design is extremely miniaturized with total structure size of 13 × 25 × 0.254 mm3. The simulated and measured results have been presented. Measured and simulated return loss values for designed antenna are less than −10 dB over the operating band and lowest values of −35 dB and −32.5 dB can been seen at 5.2 GHz and 9.2 GHz, respectively, whereas at the center frequency the return loss is −25.2 dB. The mutual coupling between both elements is less than −20 dB over the transmission bandwidth. Simulated and measured radiation patterns in E and H planes at center frequency show nearly isotropic far fields. The maximum gain is measured as 4.8 dB. Promising results of Envelope Correlation Coefficient and gain diversity of the design have been achieved. Simulated and measured results are found in good agreement. The fractional bandwidth of antenna is measured as 143.2% which satisfies its ultra‐wide band response.