This article proposes an efficient and complete wireless power transfer (WPT) system (WPTS) for multipurpose biomedical implants. The WPTS is composed of a self-diplexing implantable antenna, efficient rectifier, and WPT transmitter (WPT Tx). The proposed system is capable of simultaneously transmitting recorded data and recharging the batteries of the devices (so as to elongate the implant life). The WPT Tx occupies dimensions of 50 ×50 ×1.6 mm 3 and is optimized to effectively transfer power at 1470 MHz to a 55-mm deep implantable device. An efficient and compact ( 3.4 ×6.7 mm 2 ) rectifier is used at 1470 MHz to convert the harvested RF power into a useful direct current (dc) power. The proposed rectifier circuit exhibits a high conversion efficiency of 50% even at an input power of -14 dBm and maximum efficiency of 76.1% at 2 dBm. The proposed self-diplexing implantable antenna occupies small dimensions (9.4 mm 3 ) and operates at 915 and 1470 MHz by exciting ports 1 and 2, respectively. The biotelemetry operation is performed using a 915 MHz band (port 1), and the rectifier circuit is connected to port 2 (1470 MHz) to perform wireless powering. The simulated results are validated by examining the individual elements (WPT Tx, rectifier, and self-diplexing antenna) and overall WPTS in a saline solution and minced pork. The results prove that the proposed scheme is suitable for biotelemetry and wireless powering of biomedical implants.
Passive operation and battery-charging of deep-body implants can be insured through wireless power transfer (WPT) technologies. However, the power transfer efficiency (PTE) is constrained by device miniaturization and implantation depth. This study proposes a complete WPT system consisting of a patterned WPT transmitter (Tx), an efficient rectifier, and an antenna integrated with the system. The WPT Tx had a size of 6 cm x 6 cm and was optimized to focus the power on the deep-tissue implants at 1470 MHz. The voltage doubler was optimized at 1470 MHz, had a small size of 5 mm x 10 mm, and exhibited a high radio frequency (RF)-to-direct current (dc) conversion efficiency of 90% at 2-dBm RF input power. Moreover, the implantable antenna occupies a small volume of 8.43 mm³ and supports quad-band operations: telemetry at 403 and 915 MHz, WPT at the midfield band of 1470 MHz, and control signaling at 2.4 GHz. First, the fabricated prototypes were measured individually in minced pork, in the American Society for Testing and Materials (ASTM) model, and in the saline-filled 3-D head phantom. While operating collectively as an integrated system, the PTE of the system was measured. Additionally, to enhance the PTE of the WPT system, a high-dielectric matching layer (ϵr = 78) was used between the WPT Tx and the phantom. Furthermore, to demonstrate the PTE of the WPT system, the voltage doubler was integrated with the implantable antenna, encapsulated in a 3-D-printed capsule endoscope, and its PTE was measured in a saline solution and minced pork. Finally, the compliance of the WPT system with the human safety standards was analyzed and found that the system solely satisfied the safety limits. It is evident from the experimental results that the system can transfer 6.7-mW power to millimeter-sized implants located 5-cm deep in tissues.
9 June 2020 in IEEE Transactions on Antennas and Propagation
In this study, the first-ever dual-circular-polarized wideband conformal endoscopic antenna is designed at the medical implant communication service band (402 MHz) and industrial, scientific, and medical bands (915 MHz, and 2.4 GHz). The proposed antenna with a small footprint of 8 mm3 (32 mm × 10 mm × 0.025 mm) is printed on flexible polyamide and wrapped onto the inner wall of the capsule to spare the space for the capsule integrated components. For evaluation of the antennas performance within a full-package endoscopic device, a homogeneous muscle box and realistic Duke human phantoms were used. For measurement, the fabricated antenna is enclosed inside a 3D-printed capsule along with the endoscopic system, and the enclosed system is waterproofed. The S-parameters and radiation patterns are measured in a saline-filled American Society for Testing and Materials (ASTM) model and in a mincedpork phantom. The measured impedance bandwidths and gains at 402 MHz, 915 MHz, and 2.4 GHz are 236.2%, 104%, and 55.4%; and -29.71 dBi, -28.7 dBi, and -20.8 dBi, respectively. The measured axial-ratio bandwidths are 45.9% and 21.3% at 915 MHz and 2.4 GHz, respectively. Further, the link budget is numerically analyzed and measured via real-time telemetry using software-defined radios. The proposed antenna complies well with the human safety standards and satisfies the range and high data-rate requirements.
14 July 2020 in IEEE Transactions on Antennas and Propagation
Advancement in the technology of leadless cardiac pacemakers (LCPs) has led to ultra-compact designs of implantable antennas. In this study, we developed a small-sized antenna for integration with an LCP that can be operated in the industrial, scientific, and medical (ISM) band of 2.4 GHz. The proposed antenna was constructed in a spiral shape to provide superior miniaturization, less sensitivity to body tissue variation, low specific absorption (SAR) values, and avoid fabrication complexities owing to its small size. The antenna with a footprint of 3 × 4 × 0.5 mm3 was constructed on a high dielectric material, namely Rogers RT/duroid 6010. To the best of our knowledge, this is the smallest footprint with enhanced performance when compared to previous reports related to implantable antennas. Additionally, the antenna was integrated with a 3D printed LCP having dummy electronics and experimentally validated in saline solution and minced pork. The antenna sustained good impedance matching at the ISM band with a measured bandwidth of 21.88% and 15.46% with the device and without the device, respectively. Owing to the smooth electric field (surface currents) over the patch, the antenna system had, respectively, 270.28 and 31.04 W/kg peak SAR for 1 and 10 g of tissues with a maximum peak gain of -25.95 dBi. We also discussed the effects of a coaxial cable and the antenna orientation on its performance. From the measured received signal strength, a stable biotelemetric link can be established between the implant and external controlling device up to a distance of 2 m.
In this paper, a metamaterial structure is presented to lower the mutual coupling between the closely spaced microstrip patch antenna elements. Two elements Multiple Input Multiple Output (MIMO) antenna is closely placed with each other at edge to edge separation of 0.135 (7 mm). Isolation improvement of 9 dB is achieved by keeping the metamaterial structure in between the MIMO elements. With the proposed structure, the isolation is achieved around −24.5 dB. Due to low ECC, high gain, low channel capacity loss and very low mutual coupling between elements, the proposed antenna is a good candidate for the MIMO applications. The proposed antenna is fabricated and tested. A reasonable agreement between simulated and measured results is observed.