Junwei Yin

Dr. Junwei Yin


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2022 in Coatings
Verified
Journal Article
Open access
PDF file
YCYunxian Cui
Yunxian Cui
HLHui Liu
Hui Liu
HWhaoyu Wang
haoyu Wang
SGShuning Guo
Shuning Guo
MEMingfeng E
Mingfeng E
JYJunwei Yin
Junwei Yin
An accurate and continuous measurement of heat flux is needed in many long-term operation facilities in order to monitor and improve the life of its machinery. A thin film heat flux sensor is usually fabricated via sputtering, according to different spatial arrangements of thermocouple junctions. A novel thin film heat flux sensor was designed, fabricated, and calibrated, but the connection between the thin film and the leads could not be fixed quickly and steadily. For this purpose, in this paper a method to seamlessly integrate the leads and the thin film has been proposed to improve the sensor output signal. The sensor is capable of simultaneously measuring surface heat flux and temperature magnitude, to address the current situation of the single design of heat flux sensors. The novel thin film heat flux sensor is structured as follows: Thirty pairs of NiCr-NiSi thermocouple junctions are deposited in an annular pattern on a well-designed ceramic substrate. Over the annular thermopile, a 2000 nm-thick thermal insulator layer is deposited to create a temperature gradient across the layers. In addition, in this study a new calibration method was used to evaluate the static and dynamic properties of this novel thin film heat flux sensor. The analysis and experimental results show that the heat flux calculated from the sensor output was in good agreement with the value obtained from the pre-calibrated standard sensor. The sensitivity and response time of the novel sensor were measured at 0.06 mV/(kW/m2) and 475 ms, respectively. The heat flux measurements made with the sensor presented good repeatability. The heat-transfer coefficient of the Al2O3 thin film was 4.477 w/(m∙k) for the novel thin film heat flux sensor described in this paper.

7 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
YCYunxian Cui
Yunxian Cui
PGPenngfei Gao
Penngfei Gao
WTWuchu Tang
Wuchu Tang
GMGuowei Mo
Guowei Mo
JYJunwei Yin
Junwei Yin
With the continuous improvement of train speeds, it is necessary to find the possible problems of bearings in time, otherwise they will cause serious consequences. Aiming at the characteristics of rapid temperature change of bearings, a thin film thermocouple temperature sensor was developed to measure the real-time temperature of the bearing’s rolling elements during train operation. Using dc pulse magnetron sputtering technology, Al2O3 film, NiCr film, NiSi film, and SiO2 film were successively deposited on an aluminum alloy substrate. We studied their microstructure, static characteristics, dynamic characteristics, and repeatability. Finally, we installed an adaptive film temperature sensor on the bearing testing machine to measure the temperature of the rolling elements. The results show that the developed temperature sensor has good linearity in the range of 30~180 ℃. The Seebeck coefficient is 40.69 μV/℃, the nonlinear fitting error is less than 0.29%, the maximum repeatability error is less than 4.55%, and the dynamic response time is 1.42 μs. The temperature of the measured rolling elements is 6~10 ℃ higher than that of the outer ring, which can reflect the actual temperature of the bearing operation.

14 September 2023 in Journal of Intelligent Manufacturing
Verified
Journal Article
Closed access
PDF file
SWShugui Wang
Shugui Wang
YCYunxian Cui
Yunxian Cui
YSYuxin Song
Yuxin Song
CDChenggang Ding
Chenggang Ding
WDWanyu Ding
Wanyu Ding
JYJunwei Yin
Junwei Yin

8 June 2022 in Energies
Verified
Journal Article
Open access
PDF file
PGPenngfei Gao
Penngfei Gao
WTWuchu Tang
Wuchu Tang
YCYunxian Cui
Yunxian Cui
YWYuchen Wang
Yuchen Wang
GMGuowei Mo
Guowei Mo
JYJunwei Yin
Junwei Yin
The research on the thermal characteristics of railway double-row tapered roller bearing is of great significance for its structural design and operation monitoring. We established the quasi-static mechanical model of the bearing according to the test conditions, and we obtained the load distribution and kinematic parameters of the bearing. We studied the temperature distribution of railway double-row tapered roller bearing under test conditions through finite element analysis, which was consistent with the test results. We built a bearing testbed to study the effects of different rotating speeds on the temperature distribution of the bearing inner ring, outer ring, and roller. The results show that the speed dramatically affects the bearing inner ring. With the rate increase, the temperature difference between the inner and outer rings decreases gradually, and the temperature at the large end of the roller is the highest.

7 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
YCYunxian Cui
Yunxian Cui
XLXin Li
Xin Li
TZTenglun Zhang
Tenglun Zhang
WDWanyu Ding
Wanyu Ding
JYJunwei Yin
Junwei Yin
Aero-engine turbine stator blades are often used in harsh environments with high temperatures and high pressure and are prone to fatigue fractures. Real-time and accurate monitoring of blade surface stress and strain is critical to ensure safe operation. In this study, thin-film strain gauges (TFSGs) that can be used in high-temperature environments above 1000 °C were designed and fabricated using a PtRh6 thin film as the sensitive material. The hysteresis effect of the stress transfer upon establishing a thermo-mechanical coupling finite element model of the Inconel718 high-temperature nickel-based alloy equal-strength beam PtRh6 TFSGs was analyzed and the optimal combination of thin-film thickness and longitudinal grid length of wire-grid TFSGs was determined. In order to solve the problem of high-temperature insulation, the insulating properties of a single-layer Al2O3 insulating film, a single-layer ZrO2 insulating film, a double-layer Al2O3/ZrO2 composite insulating film, and a four-layer Al2O3/ZrO2/Al2O3/ZrO2 composite insulating film at high temperature were compared and studied using scanning electron microscopy to analyze the microscopic morphology and composition of the four insulating film structures. The results showed that the four-layer Al2O3/ZrO2/Al2O3/ZrO2 composite insulating film had the best insulating properties at high temperatures. On this basis, an Al2O3/ZrO2/Al2O3/ZrO2 composite insulating film, PtRh6 sensitive layer, and Al2O3 protective film were sequentially deposited on a high-temperature nickel-based alloy equal-strength beam using DC pulsed magnetron sputtering technology to obtain an Inconel718 high-temperature nickel-based alloy equal-strength beam PtRh6 TFSG. Its gauge factor (GF) and temperature coefficient of resistance (TCR) were calibrated, and the results showed that the sensor could be used in harsh environments of 1000 °C. The above results provide new ideas for measuring stress and strain in aerospace under high-temperature and high-pressure environments.

13 October 2022 in Materials
Verified
Journal Article
Open access
PDF file
YCYunxian Cui
Yunxian Cui
HWhaoyu Wang
haoyu Wang
KCKaidi Cao
Kaidi Cao
QZQunli Zhou
Qunli Zhou
WDWanyu Ding
Wanyu Ding
JYJunwei Yin
Junwei Yin
During the titanium alloy milling process, high temperatures in the tool-chip contact area will affect the tool life and precision of titanium alloy machining. Therefore, it is essential to measure the temperature of the tool-chip contact area continuously. In this paper, a finite element simulation model of the milling process was established using ABAQUS2020 to obtain the highest temperature location in the tool-chip contact area when milling titanium alloy. The integration of the wire with the alumina ceramic substrate formed an integrated wire substrate. Furthermore, NiCr, NiSi, and SiO2 films were deposited on the substrate sequentially using the DC pulsed magnetron sputtering technique. Finally, its microscopic morphology and static and dynamic performance were tested. The results show that the developed thin-film thermocouple temperature sensor has a Seebeck coefficient of 40.72 μV/°C and a dynamic response time of 0.703 ms. The application of the sensor to our titanium alloy milling experiments showed that the sensor can monitor the transient temperature in the tool-chip contact area, and its temperature measurement performance showed no detrimental effect from wearing. The effect of each milling parameter on the milling temperature was analyzed using ANOVA, and a regression model with an R-sq of 96.76% was obtained for the milling temperature.