一喜 久我

Dr. 一喜 久我

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2022 in Building and Environment
Verified
Journal Article
Open access
XFXiaojun Fan
Xiaojun Fan
HSHuiqi Shao
Huiqi Shao
MSMitsuharu Sakamoto
Mitsuharu Sakamoto
一久一喜 久我
一喜 久我
LLLi Lan
Li Lan
PWPawel Wargocki
Pawel Wargocki


11 March 2020 in Indoor Air
Verified
Journal Article
Closed access
PDF file
一久一喜 久我
一喜 久我
KIKazuhide Ito
Kazuhide Ito
WCWenhao Chen
Wenhao Chen
PWPing Wang
Ping Wang
KKKazukiyo Kumagai
Kazukiyo Kumagai

22 March 2023 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
一久一喜 久我
一喜 久我
RKRyusei Kizuka
Ryusei Kizuka
KNKhoa Dang Nguyen
Khoa Dang Nguyen
KIKazuhide Ito
Kazuhide Ito

1 August 2021 in Indoor Air
Verified
Journal Article
Open access
PDF file
XFXiaojun Fan
Xiaojun Fan
MSMitsuharu Sakamoto
Mitsuharu Sakamoto
HSHuiqi Shao
Huiqi Shao
一久一喜 久我
一喜 久我
KIKazuhide Ito
Kazuhide Ito
PWPawel Wargocki
Pawel Wargocki
Humans emit carbon dioxide (CO2) as a product of their metabolism. Its concentration in buildings is used as a marker of ventilation rate (VR) and degree of mixing of supply air, and indoor air quality (IAQ). The CO2 emission rate (CER) may be used to estimate the ventilation rate. Many studies have measured CERs from subjects who were awake but little data are available from sleeping subjects and the present publication was intended to reduce this gap in knowledge. Seven females (29 ± 5 years old; BMI: 22.2 ± 0.8 kg/m2) and four males (27 ± 1 years old; BMI: 20.5 ± 1.5 kg/m2) slept for four consecutive nights in a specially constructed capsule at two temperatures (24 and 28°C) and two VRs that maintained CO2 levels at ca. 800 ppm and 1700 ppm simulating sleeping conditions reported in the literature. The order of exposure was balanced, and the first night was for adaptation. Their physiological responses, including heart rate, pNN50, core body temperature, and skin temperature, were measured as well as sleep quality, and subjective responses were collected each evening and morning. Measured steady-state CO2 concentrations during sleep were used to estimate CERs with a mass-balance equation. The average CER was 11.0 ± 1.4 L/h per person and was 8% higher for males than for females (P < 0.05). Increasing the temperature or decreasing IAQ by decreasing VR had no effects on measured CERs and caused no observable differences in physiological responses. We also calculated CERs for sleeping subjects using the published data on sleep energy expenditure (SEE) and Respiratory Quotient (RQ), and our measured CERs confirmed both these calculations and the CERs predicted using the equations provided by ASHRAE Standard 62.1, ASHRAE Handbook, and ASTM D6245-18. The present results provide a valuable and helpful reference for the design and control of bedroom ventilation but require confirmation and extension to other age groups and populations.

1 March 2022 in Building and Environment
Verified
Journal Article
Open access
MSMitsuharu Sakamoto
Mitsuharu Sakamoto
MLMengze Li
Mengze Li
一久一喜 久我
一喜 久我
KIKazuhide Ito
Kazuhide Ito
GBGabriel Bekö
Gabriel Bekö
PWPawel Wargocki
Pawel Wargocki