Viviana Benfante

Dr. Viviana Benfante

University of Palermo, Palermo, Sicilia, Italy
orcid
Ph.D., Researcher, Scientist in Radiobiology and Molecular I...

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2025 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
Muhammad AliMuhammad Ali
Muhammad Ali
Viviana BenfanteViviana Benfante
Viviana Benfante
GBGhazal Basirinia
Ghazal Basirinia
Pierpaolo AlongiPierpaolo Alongi
Pierpaolo Alongi
ASAlessandro Sperandeo
Alessandro Sperandeo
Albert ComelliAlbert Comelli
Albert Comelli
Artificial intelligence (AI) transforms image data analysis across many biomedical fields, such as cell biology, radiology, pathology, cancer biology, and immunology, with object detection, image feature extraction, classification, and segmentation applications. Advancements in deep learning (DL) research have been a critical factor in advancing computer techniques for biomedical image analysis and data mining. A significant improvement in the accuracy of cell detection and segmentation algorithms has been achieved as a result of the emergence of open-source software and innovative deep neural network architectures. Automated cell segmentation now enables the extraction of quantifiable cellular and spatial features from microscope images of cells and tissues, providing critical insights into cellular organization in various diseases. This review aims to examine the latest AI and DL techniques for cell analysis and data mining in microscopy images, aid the biologists who have less background knowledge in AI and machine learning (ML), and incorporate the ML models into microscopy focus images.

18 January 2024 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
Muhammad AliMuhammad Ali
Muhammad Ali
Viviana BenfanteViviana Benfante
Viviana Benfante
Domenico Di RaimondoDomenico Di Raimondo
Domenico Di Raimondo
Giuseppe SalvaggioGiuseppe Salvaggio
Giuseppe Salvaggio
Antonino TuttolomondoAntonino Tuttolomondo
Antonino Tuttolomondo
Albert ComelliAlbert Comelli
Albert Comelli
Resveratrol is a polyphenolic compound that has gained considerable attention in the past decade due to its multifaceted therapeutic potential, including anti-inflammatory and anticancer properties. However, its anticancer efficacy is impeded by low water solubility, dose-limiting toxicity, low bioavailability, and rapid hepatic metabolism. To overcome these hurdles, various nanoparticles such as organic and inorganic nanoparticles, liposomes, polymeric nanoparticles, dendrimers, solid lipid nanoparticles, gold nanoparticles, zinc oxide nanoparticles, zeolitic imidazolate frameworks, carbon nanotubes, bioactive glass nanoparticles, and mesoporous nanoparticles were employed to deliver resveratrol, enhancing its water solubility, bioavailability, and efficacy against various types of cancer. Resveratrol-loaded nanoparticle or resveratrol-conjugated nanoparticle administration exhibits excellent anticancer potency compared to free resveratrol. This review highlights the latest developments in nanoparticle-based delivery systems for resveratrol, focusing on the potential to overcome limitations associated with the compound’s bioavailability and therapeutic effectiveness.

30 October 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Alessandro StefanoAlessandro Stefano
Alessandro Stefano
APAntonio Leal Plaza
Antonio Leal Plaza
Selene RichiusaSelene Richiusa
Selene Richiusa
PTPhan Trang
Phan Trang
Albert ComelliAlbert Comelli
Albert Comelli
Giorgio RussoGiorgio Russo
Giorgio Russo
Radiomics holds great promise in the field of cancer management. However, the clinical application of radiomics has been hampered by uncertainty about the robustness of the features extracted from the images. Previous studies have reported that radiomics features are sensitive to changes in voxel size resampling and interpolation, image perturbation, or slice thickness. This study aims to observe the variability of positron emission tomography (PET) radiomics features under the impact of co-registration with magnetic resonance imaging (MRI) using the difference percentage coefficient, and the Spearman’s correlation coefficient for three groups of images: (i) original PET, (ii) PET after co-registration with T1-weighted MRI and (iii) PET after co-registration with FLAIR MRI. Specifically, seventeen patients with brain cancers undergoing [11C]-Methionine PET were considered. Successively, PET images were co-registered with MRI sequences and 107 features were extracted for each mentioned group of images. The variability analysis revealed that shape features, first-order features and two subgroups of higher-order features possessed a good robustness, unlike the remaining groups of features, which showed large differences in the difference percentage coefficient. Furthermore, using the Spearman’s correlation coefficient, approximately 40% of the selected features differed from the three mentioned groups of images. This is an important consideration for users conducting radiomics studies with image co-registration constraints to avoid errors in cancer diagnosis, prognosis, and clinical outcome prediction.

19 November 2020 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
Albert ComelliAlbert Comelli
Albert Comelli
CCClaudia Coronnello
Claudia Coronnello
Navdeep DahiyaNavdeep Dahiya
Navdeep Dahiya
Viviana BenfanteViviana Benfante
Viviana Benfante
Stefano PalmucciStefano Palmucci
Stefano Palmucci
Alessandro StefanoAlessandro Stefano
Alessandro Stefano
Background: The aim of this work is to identify an automatic, accurate, and fast deep learning segmentation approach, applied to the parenchyma, using a very small dataset of high-resolution computed tomography images of patients with idiopathic pulmonary fibrosis. In this way, we aim to enhance the methodology performed by healthcare operators in radiomics studies where operator-independent segmentation methods must be used to correctly identify the target and, consequently, the texture-based prediction model. Methods: Two deep learning models were investigated: (i) U-Net, already used in many biomedical image segmentation tasks, and (ii) E-Net, used for image segmentation tasks in self-driving cars, where hardware availability is limited and accurate segmentation is critical for user safety. Our small image dataset is composed of 42 studies of patients with idiopathic pulmonary fibrosis, of which only 32 were used for the training phase. We compared the performance of the two models in terms of the similarity of their segmentation outcome with the gold standard and in terms of their resources’ requirements. Results: E-Net can be used to obtain accurate (dice similarity coefficient = 95.90%), fast (20.32 s), and clinically acceptable segmentation of the lung region. Conclusions: We demonstrated that deep learning models can be efficiently applied to rapidly segment and quantify the parenchyma of patients with pulmonary fibrosis, without any radiologist supervision, in order to produce user-independent results.

30 March 2022 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
Viviana BenfanteViviana Benfante
Viviana Benfante
Alessandro StefanoAlessandro Stefano
Alessandro Stefano
Albert ComelliAlbert Comelli
Albert Comelli
Paolo GiacconePaolo Giaccone
Paolo Giaccone
Francesco Paolo CammarataFrancesco Paolo Cammarata
Francesco Paolo Cammarata
Giorgio RussoGiorgio Russo
Giorgio Russo
The 64Cu-labeled chelator was analyzed in vivo by positron emission tomography (PET) imaging to evaluate its biodistribution in a murine model at different acquisition times. For this purpose, nine 6-week-old female Balb/C nude strain mice underwent micro-PET imaging at three different time points after 64Cu-labeled chelator injection. Specifically, the mice were divided into group 1 (acquisition 1 h after [64Cu] chelator administration, n = 3 mice), group 2 (acquisition 4 h after [64Cu]chelator administration, n = 3 mice), and group 3 (acquisition 24 h after [64Cu] chelator administration, n = 3 mice). Successively, all PET studies were segmented by means of registration with a standard template space (3D whole-body Digimouse atlas), and 108 radiomics features were extracted from seven organs (namely, heart, bladder, stomach, liver, spleen, kidney, and lung) to investigate possible changes over time in [64Cu]chelator biodistribution. The one-way analysis of variance and post hoc Tukey Honestly Significant Difference test revealed that, while heart, stomach, spleen, kidney, and lung districts showed a very low percentage of radiomics features with significant variations (p-value < 0.05) among the three groups of mice, a large number of features (greater than 60% and 50%, respectively) that varied significantly between groups were observed in bladder and liver, indicating a different in vivo uptake of the 64Cu-labeled chelator over time. The proposed methodology may improve the method of calculating the [64Cu]chelator biodistribution and open the way towards a decision support system in the field of new radiopharmaceuticals used in preclinical imaging trials.

26 June 2023 in Life
Verified
Journal Article
Open access
PDF file
ACAntonio Lo Casto
Antonio Lo Casto
GSGiacomo Spartivento
Giacomo Spartivento
Viviana BenfanteViviana Benfante
Viviana Benfante
RRRiccardo Di Raimondo
Riccardo Di Raimondo
Muhammad AliMuhammad Ali
Muhammad Ali
Albert ComelliAlbert Comelli
Albert Comelli
The purpose of this investigation was to evaluate the diagnostic performance of two convolutional neural networks (CNNs), namely ResNet-152 and VGG-19, in analyzing, on panoramic images, the rapport that exists between the lower third molar (MM3) and the mandibular canal (MC), and to compare this performance with that of an inexperienced observer (a sixth year dental student). Utilizing the k-fold cross-validation technique, 142 MM3 images, cropped from 83 panoramic images, were split into 80% as training and validation data and 20% as test data. They were subsequently labeled by an experienced radiologist as the gold standard. In order to compare the diagnostic capabilities of CNN algorithms and the inexperienced observer, the diagnostic accuracy, sensitivity, specificity, and positive predictive value (PPV) were determined. ResNet-152 achieved a mean sensitivity, specificity, PPV, and accuracy, of 84.09%, 94.11%, 92.11%, and 88.86%, respectively. VGG-19 achieved 71.82%, 93.33%, 92.26%, and 85.28% regarding the aforementioned characteristics. The dental student’s diagnostic performance was respectively 69.60%, 53.00%, 64.85%, and 62.53%. This work demonstrated the potential use of deep CNN architecture for the identification and evaluation of the contact between MM3 and MC in panoramic pictures. In addition, CNNs could be a useful tool to assist inexperienced observers in more accurately identifying contact relationships between MM3 and MC on panoramic images.