Daniel Sim

Dr. Daniel Sim


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
IDIl Doh
Il Doh
DSDaniel Sim
Daniel Sim
SKSteve Kim
Steve Kim
This paper presents a microfluidic thermal flowmeter for monitoring injection pumps, which is essential to ensure proper patient treatment and reduce medication errors that can lead to severe injury or death. The standard gravimetric method for flow-rate monitoring requires a great deal of preparation and laboratory equipment and is impractical in clinics. Therefore, an alternative to the standard method suitable for remote, small-scale, and frequent infusion-pump monitoring is in great demand. Here, we propose a miniaturized thermal flowmeter consisting of a silicon substrate, a platinum heater layer on a silicon dioxide thin-membrane, and a polymer microchannel to provide accurate flow-rate measurement. The present thermal flowmeter is fabricated by the micromachining and micromolding process and exhibits sensitivity, linearity, and uncertainty of 0.722 mW/(g/h), 98.7%, and (2.36 ± 0.80)%, respectively, in the flow-rate range of 0.5–2.5 g/h when the flowmeter is operated in the constant temperature mode with the channel width of 0.5 mm. The measurement range of flow rate can be easily adjusted by changing the cross-sectional microchannel dimension. The present miniaturized thermal flowmeter shows a high potential for infusion-pump calibration in clinical settings.

14 October 2023 in Sensors
Verified
Journal Article
Open access
PDF file
DSDaniel Sim
Daniel Sim
THTiffany Huang
Tiffany Huang
SKSteve Kim
Steve Kim
Biorecognition element (BRE)-based carbon nanotube (CNT) chemiresistors have tremendous potential to serve as highly sensitive, selective, and power-efficient volatile organic compound (VOC) sensors. While many research groups have studied BRE-functionalized CNTs in material science and device development, little attention has been paid to optimizing CNT density to improve chemiresistor performance. To probe the effect of CNT density on VOC detection, we present the chemiresistor-based sensing results from two peptide-based CNT devices counting more than 60 different individual measurements. We find that a lower CNT density shows a significantly higher noise level and device-to-device variation while exhibiting mildly better sensitivity. Further investigation with SEM images suggests that moderately high CNT density with a stable connection of the nanotube network is desirable to achieve the best signal-to-noise ratio. Our results show an essential design guideline for tuning the nanotube density to provide sensitive and stable chemiresistors.