The escalating demand for electric vehicles (EVs) arises from apprehensions regarding fossil fuel depletion and the ecological repercussions of conventional combustion engines, propelling the transition towards environmentally sustainable alternatives. EVs are conventionally comprised of a powertrain, battery management system, and communication infrastructure, with the battery playing a pivotal role. Achieving an efficient EV battery charger necessitates the implementation of a proficient charging algorithm and a high-power converter capable of adeptly regulating battery parameters. Among the array of available options, a bi-directional DC/DC converter is often employed for this purpose. This study predominantly focuses on the Bi-Directional Dual Active Bridge Converter with Single-Phase Shift Control. It is renowned for attaining a broad voltage range through transformer turn ratio adjustments. Its controllable parameters, such as phase shift ratio and duty cycle, bolster its versatility. Moreover, due to its input–output isolation and minimal passive elements, this converter exhibits superior efficiency due to its soft-switching capabilities. The analytical framework encompasses steady-state and dynamic assessments, small-signal modeling, and system transfer function analysis, all of which contribute to formulating an optimized controller design. Additionally, the study conducts simulations of various battery charging techniques, including constant current (CC), constant voltage (CV), and CCCV mode, employing a 1.5 kW Dual Active Bridge DAB-based charger through MATLAB/SIMULINK. Furthermore, voltage mode control simulations for a 5 kW DAB converter augment the study's insights into effective EV charging strategies.
21 April 2025 in Science and Technology for Energy Transition
The increasing complexity and demand for reliability in modern power systems necessitate advanced techniques for fault detection, classification, and location. This work presents a comprehensive study on the application of Artificial Neural Network (ANN) and Adaptive Neuro-Fuzzy Inference System (ANFIS) for fault management in power systems. ANFIS, combining the benefits of neural networks and fuzzy logic, offers a robust framework for handling the non-linearities and uncertainties inherent in power system faults. The proposed method leverages historical fault data to train the ANFIS model, enabling it to accurately detect, classify, and locate various types of faults, including line-to-ground, line-to-line, and three-phase faults. The model’s performance is evaluated using a simulated power system environment, and its effectiveness is validated through extensive testing under different fault scenarios. Results demonstrate that the ANFIS-based approach achieves high accuracy in fault detection and classification, significantly reducing the response time. Additionally, the system exhibits a strong capability in pinpointing fault locations with minimal error margins. This research underscores the potential of ANFIS as a powerful tool for improving the consistency and competence of fault management in power systems. The findings suggest that integrating ANFIS into existing protection schemes can lead to improved operational efficiency (97–99%), whereas in case of ANN, the efficiency is (92–95%) resilience and reduced downtime. Future work will focus on real-time implementation and the incorporation of ANFIS with other smart grid technologies to further augment fault management capabilities.
16 June 2025 in International Journal of Robust and Nonlinear Control
This paper presents a comprehensive framework for fault detection, control, and operation within a DC microgrid (DCMG) incorporating diverse energy sources like wind, solar photovoltaic (PV), battery energy storage systems (BESS), utility grid, fuel cells (FC), and load. The DCMG faces challenges due to intermittent faults in the DC link and the necessity to distinguish between low and high fault levels. A resistance-based fault detection scheme is proposed to address these issues, enabling efficient fault detection without necessitating a complete shutdown of the DCMG. Perturb and Observe (P&O) techniques are employed for PV and wind power tracking, while proportional-integral (PI) controllers are utilized for FC and BESS control. In mitigating voltage and current (V-I) fluctuations, fuzzy logic controllers (FLCs) exhibit superior performance compared to traditional PI methods. For the favorable variation of the DC-link V-I level, the traditional PI controller is tuned with a genetic algorithm (GA-PIC) based optimization technique and evolution-inspired PI controller. Additionally, PI controllers undergo optimization via a genetic algorithm (GA), ensuring adherence to V-I limits. The proposed method to investigate fault responses is validated on test systems developed in the OPAL-RT simulator under different scenarios. It Demonstrates improvements over un-optimized counterparts with optimized configuration. This research advances DCMGs by improving their efficiency, stability, and performance.