The paper addresses the ongoing and continuous interest in photovoltaic energy systems (PESs). In this context, the study focuses on an isolated photovoltaic system with hybrid battery-supercapacitor storage (HBSS). The integration of supercapacitors (SCs) in this system is particularly important because of their high specific power density. In photovoltaic (PV) systems, multi-storage systems use two or more energy storage technologies to enhance system performance and flexibility. When batteries and supercapacitors are combined in a PV system, their benefits are maximized and offer a more reliable, efficient, cost-effective energy storage option. In addition, effective multi-storage power management in a PV system needs a solid grasp of the energy storage technologies, load power demand profiles, and the whole system architecture. This work establishes a battery-supercapacitor storage system (HBSS) by combining batteries and supercapacitors. The primary objective is to devise a novel management algorithm that effectively controls the different power sources. The algorithm is designed to manage the charge and discharge cycles of the hybrid battery-supercapacitor energy storage system (HBSS), thereby guaranteeing that the state of charge (SOC) for both batteries and supercapacitors is maintained within the specified range. The proposed management algorithm is designed to be simple, efficient, and light on computational resources. It efficiently handles the energy flow within the HBSS, optimizing the usage of both batteries and supercapacitors based on real-time conditions and energy demands. The proposed method ensures their longevity and maximizes their performance by maintaining the SOC of these energy storage components within the specified limits. Simulation results obtained from applying the management strategy are found to be satisfactory. These results show that the proposed algorithm maintains the SOC of batteries and supercapacitors within the desired range, leading to improved energy management and enhanced system efficiency.
The paper addresses the ongoing and continuous interest in photovoltaic energy systems (PESs). In this context, the study focuses on an isolated photovoltaic system with hybrid bat-tery-supercapacitor storage (HBSS). The integration of supercapacitors (SCs) in this system is of particular importance because of their high specific power density. In photovoltaic (PV) systems, multi-storage systems use two or more energy storage technologies to enhance system perfor-mance and flexibility. When batteries and supercapacitors are combined in a PV system, their benefits are maximized and offer a more reliable, efficient, and cost-effective energy storage op-tion. In addition, effective multi-storage power management in a PV system needs a solid grasp of the energy storage technologies, load power demand profiles, and the whole system architecture. In this work, battery-supercapacitor storage system (HBSS) is established by combining batteries and supercapacitors. The primary objective is to devise a novel management algorithm that ef-fectively controls the different power sources. The algorithm's purpose is to regulate the charge and discharge cycles of the HBSS, ensuring that the state of charge (SOC) of both batteries and supercapacitors remains within the desired range. The proposed management algorithm is de-signed to be simple, efficient, and light on computational resources. It efficiently handles the energy flow within the HBSS, optimizing the usage of both batteries and supercapacitors based on real-time conditions and energy demands. By maintaining the SOC of these energy storage components within the specified limits, the proposed method ensures their longevity and max-imizes their performance. Simulation results obtained from applying the management strategy are found to be satisfactory. These results show that the proposed algorithm maintains the SOC of batteries and supercapacitors within the desired range, leading to improved energy management and enhanced system efficiency.
This article presents a study on the performance characteristics of a Francis turbine operating with various guide vane openings to determine the best operating point based on unit quantities. The guide vane openings were specified based on the width between the vanes at their exit, i.e., 10 mm, 13 mm, 16 mm, and 19 mm. The performance characteristic curves of the Francis turbine—head versus speed, torque versus speed, discharge versus speed, and efficiency versus speed—were obtained at various input power and guide vane openings. From these data, unit curves were plotted and the corresponding best efficiency points were obtained. The highest efficiency of 50.25% was obtained at a guide vane opening of 19 mm. The values of head, discharge, speed, and output power at BEP were 7.84 m, 13.55 lps, 1250 rpm, and 524 W, respectively.
This paper investigates the performance of the current model predictive control (CMPC) for controlling a two-stage transformerless grid-connected photovoltaic (PV) system under grid fault conditions. A maximum power point tracking (MPPT) controller was used to extract the maximum power of the PV panel. To stabilize the DC link and generate the reference current values, a proportional-integral (PI) controller was used. The CMPC strategy was implemented to control the output current of the inverter that connects the PV system to the utility grid. The system and control strategy were simulated via a MATLAB/Simulink environment. The performance of the proposed control strategy was investigated under fault conditions between the three-phase two-level inverter and the grid. Moreover, to validate the capability of the CMPC, comparative case studies were conducted between CMPC, PI, and sliding mode control (SMC) under grid fault. Case studies' results showed that under grid fault, CMPC did not introduce any overshoot or undershoot in the PV output DC current and power. However, PI and SMC produced undershoots of almost 15 kW for the output power and 45 A for the output current. Under the fault conditions, the active output power and three-phase current recovery time of the inverter was 50 ms using CMPC, compared to PI and SMC with recovery times of 80 ms and 60 ms, respectively. Moreover, a voltage dip of 75 V at the DC link voltage was recorded with CMPC under faulty conditions, while the voltage dips for PI and SMC were around 180 V.
This paper presents a comprehensive framework for fault detection, control, and operation within a DC microgrid (DCMG) incorporating diverse energy sources like wind, solar photovoltaic (PV), battery energy storage systems (BESS), utility grid, fuel cells (FC), and load. The DCMG faces challenges due to intermittent faults in the DC link and the necessity to distinguish between low and high fault levels. A resistance-based fault detection scheme is proposed to address these issues, enabling efficient fault detection without necessitating a complete shutdown of the DCMG. Perturb and Observe (P&O) techniques are employed for PV and wind power tracking, while proportional-integral (PI) controllers are utilized for FC and BESS control. In mitigating voltage and current (V-I) fluctuations, fuzzy logic controllers (FLCs) exhibit superior performance compared to traditional PI methods. For the favorable variation of the DC-link V-I level, the traditional PI controller is tuned with a genetic algorithm (GA-PIC) based optimization technique and evolution-inspired PI controller. Additionally, PI controllers undergo optimization via a genetic algorithm (GA), ensuring adherence to V-I limits. The proposed method to investigate fault responses is validated on test systems developed in the OPAL-RT simulator under different scenarios. It Demonstrates improvements over un-optimized counterparts with optimized configuration. This research advances DCMGs by improving their efficiency, stability, and performance.