Quan Han

Prof. Dr. Quan Han


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2022 in Molecules
Verified
Journal Article
Open access
PDF file
QHQuan Han
Quan Han
YLYaqi Liu
Yaqi Liu
YHYanyan Huo
Yanyan Huo
DLDan Li
Dan Li
XYXiaohui Yang
Xiaohui Yang
A novel method for the determination of ultra-trace cobalt by dispersive liquid–liquid microextraction (DLLME) coupled with graphite furnace atomic absorption spectrometry has been developed. It is based on the color reaction of Co2+ with 2-(5-bromo-2-pyridylazo)-5-dimethylaminoaniline (5-Br-PADMA) in a Britton–Robinson buffer solution at pH 6.0 to form stable hydrophobic chelates, which were separated and enriched by DLLME with 1,2-dichloroethane (CH2ClCH2Cl) as extraction and acetonitrile (CH3CN) as a dispersive solvent. The sedimented phase containing the chelates is then determined with GFAAS. Parameters that affect extraction efficiency, such as types and volumes of extraction and disperser solvents, pH of sample solution, extraction time, concentration of the chelating agent 5-Br-PADMA, and salt effect, were investigated. Under optimal conditions, the calibration graph was linear over the range 0.05–1.0 ng/mL, with a correlation coefficient of 0.9922 and a detection limit of 0.03 ng/mL. Preconcentration factor (PF) is calculated as the ratio of the aqueous solution volume (5 mL) to that of the organic phase volume (40 μL), and enrichment factor (EF) is calculated as the ratio of the slopes of the calibration graphs obtained with and without DLLME for 5.0 mL of sample solution, which were 120 and 112.5, respectively. The extraction efficiency, calculated by EF/PF·100, was 93.8%. The relative standard deviation (RSD) at the 0.5 ng/mL Co2+ level was 3.8% (n = 6). The method has been applied to the determination of trace cobalt in water samples with satisfactory results.

26 September 2024 in Journal of Water Chemistry and Technology
Verified
Journal Article
Closed access
PDF file
YLYaqi Liu
Yaqi Liu
QHQuan Han
Quan Han
YHYanyan Huo
Yanyan Huo
XYXiaohui Yang
Xiaohui Yang
A new method for the determination of ultra-trace cobalt by ionic liquid-dispersive liquid-liquid microextraction (IL-DLLME) and graphite furnace atomic ab

1 February 2022 in Journal of Water Chemistry and Technology
Verified
Journal Article
Closed access
PDF file
QHQuan Han
Quan Han
YHY. Y. Huo
Y. Y. Huo
XYX. H. Yang
X. H. Yang
YHY. P. He
Y. P. He
YZY. H. Zhai
Y. H. Zhai
A highly sensitive, simple and safe method has been developed for the determination of trace palladium by cloud point extraction (CPE) combined with therma

9 June 2026 in Molecules
Verified
Journal Article
Open access
PDF file
YLYaqi Liu
Yaqi Liu
YHYanyan Huo
Yanyan Huo
QHQuan Han
Quan Han
XYXiaohui Yang
Xiaohui Yang
A new method has been established for determining trace amounts of platinum in water using ion liquid (IL)-dispersive liquid–liquid microextraction (DLLME) combined with graphite furnace atomic absorption spectroscopy (GFAAS). The method is based on the use of a self-prepared reagent, 5-(5-cyano-2-pyridineazo)-2,4-diaminotoluene (5-CN-PADAT), as a chelating agent, which reacts with Pt(IV) to form a hydrophobic chelate. The extraction solvent is 1-octyl-3-methylimidazolium hexafluorophosphate ([C8mim][PF6]), and ethyl acetate is used as the dispersive solvent. After the extraction is completed, the extraction phase formed by [C8mim][PF6] and ethyl acetate has a relatively low viscosity and can be directly used for the determination of GFAAS. A single-factor rotational method was employed to optimize conditions affecting DLLME extraction efficiency. The interactions among the factors affecting DLLME were analyzed using response surface optimization (RSM). Under optimal conditions, platinum concentrations exhibited good linearity within the range of 40–280 ng/mL, with a detection limit of 0.3 ng/mL. AGREEprep was used to discuss the ecological friendliness of the method, demonstrating its low cost, ease of operation, simple equipment requirements, and environmental friendliness. When applied to determining trace amounts of platinum in water samples, the results were satisfactory.