A simple and sensitive cloud point extraction method for the preconcentration of ultra-trace amounts of nickel as a prior step to its determination by graphite furnace atomic absorption spectrometry was proposed. It is based on the reaction of nickel with 2-(5-bromo-2-pyridylazo)-5-dimethylaminoaniline (5-Br-PADMA) in HAc–NaAc buffer media and mixed micelle-mediated extraction of the complex using the anionic surfactant sodium dodecyl sulfate sodium (SDS) and non-ionic surfactant (1,1,3,3-Tetramethylbutyl)phenyl-polyethylene (Triton X-114). The optimal reaction and extraction conditions such as pH, concentration of 5-Br-PADMA, SDS and Triton X-114, equilibrium temperature, incubation, and centrifuge time were evaluated and optimized. Under the optimal conditions, the calibration graph was linear over the range 0.1–5.5 ng/mL of nickel with a correlation coefficient of 0.9942. The detection limit obtained was 0.031 ng/mL, and the relative standard deviation was 2.1% for nickel (c = 2 ng/mL, n = 6). The proposed method was successfully applied to the determination of nickel in water samples.
A new method of dispersive liquid-liquid microextraction (DLLME) combined with graphite furnace atomic absorption spectrometry (GFAAS) was proposed for the determination of ultra-trace copper. It was based on the reaction of Cu(II) with the laboratory-prepared chelating agent 2-(5-bromo-2-pyridylazo)-5-dimethylaminoaniline (5-Br-PADMA) in a HAc-NaAc buffer solution at pH 5.0 to form stable hydrophobic chelates, which were separated and enriched by DLLME with chlorobenzene (C6H5Cl) and acetonitrile (CH3CN) as extraction and disperser solvents, respectively. The sedimented phase containing the chelates was then determined with GFAAS. Various operating variables that may be affected by the extraction process such as the pH of the solution, the concentration of the chelating agent 5-Br-PADMA, the types and volumes of extraction and disperser solvents, the extraction time, and the centrifugation time were investigated. Under optimum conditions, the calibration curve was linear in the range from 0.02 ng/mL to 0.16 ng/mL of copper with a correlation coefficient of r = 0.9961, and the detection limit was 0.01 ng/mL based on 3Sb. The relative standard deviation for six replicate measurements of 0.05 ng /mL of copper was 3.9%. An enrichment factor (EF) of 110 was obtained. The method has the advantages of low detection limit, high sensitivity, simple operation, less consumption of organic solvents, higher enrichment factor, and environmental friendliness and was applied to the determination of trace copper in environmental water samples with satisfactory results.
A novel method for the determination of ultra-trace cobalt by dispersive liquid–liquid microextraction (DLLME) coupled with graphite furnace atomic absorption spectrometry has been developed. It is based on the color reaction of Co2+ with 2-(5-bromo-2-pyridylazo)-5-dimethylaminoaniline (5-Br-PADMA) in a Britton–Robinson buffer solution at pH 6.0 to form stable hydrophobic chelates, which were separated and enriched by DLLME with 1,2-dichloroethane (CH2ClCH2Cl) as extraction and acetonitrile (CH3CN) as a dispersive solvent. The sedimented phase containing the chelates is then determined with GFAAS. Parameters that affect extraction efficiency, such as types and volumes of extraction and disperser solvents, pH of sample solution, extraction time, concentration of the chelating agent 5-Br-PADMA, and salt effect, were investigated. Under optimal conditions, the calibration graph was linear over the range 0.05–1.0 ng/mL, with a correlation coefficient of 0.9922 and a detection limit of 0.03 ng/mL. Preconcentration factor (PF) is calculated as the ratio of the aqueous solution volume (5 mL) to that of the organic phase volume (40 μL), and enrichment factor (EF) is calculated as the ratio of the slopes of the calibration graphs obtained with and without DLLME for 5.0 mL of sample solution, which were 120 and 112.5, respectively. The extraction efficiency, calculated by EF/PF·100, was 93.8%. The relative standard deviation (RSD) at the 0.5 ng/mL Co2+ level was 3.8% (n = 6). The method has been applied to the determination of trace cobalt in water samples with satisfactory results.
A highly sensitive method based on cloud point extraction (CPE) separation/preconcentration and graphite furnace atomic absorption spectrometry (GFAAS) detection has been developed for the determination of ultra-trace amounts of rhodium in water samples. A new reagent, 2-(5-iodo-2-pyridylazo)-5-dimethylaminoaniline (5-I-PADMA), was used as the chelating agent and the nonionic surfactant TritonX-114 was chosen as extractant. In a HAc-NaAc buffer solution at pH 5.5, Rh(III) reacts with 5-I-PADMA to form a stable chelate by heating in a boiling water bath for 10 min. Subsequently, the chelate is extracted into the surfactant phase and separated from bulk water. The factors affecting CPE were investigated. Under the optimized conditions, the calibration graph was linear in the range of 0.1–6.0 ng/mL, the detection limit was 0.023 ng/mL for rhodium and relative standard deviation was 3.67% (c = 1.0 ng/mL, n = 11).The method has been applied to the determination of trace rhodium in water samples with satisfactory results
The sweetener Rebaudioside M (Reb M) has broad application prospects and can be produced on a large scale by enzymatic methods. However, detecting exogenous protein residues in Reb M products remains a major challenge, and methods for detecting protein residues in Reb M have rarely been reported. In this study, Reb M was dissolved in a sodium hydroxide solution to improve its solubility, and proteins were precipitated using deoxycholic acid sodium and trichloroacetic acid solutions. This precipitation method also eliminated the interference of Reb M in the detection results. After reconstituting the residual protein with water, the protein content in Reb M was measured using the bicinchoninic acid (BCA) method. The analytical method was internally validated according to the following parameters: range of linearity, limits of detection, limits of quantification, sensitivity, accuracy, and precision. The recoveries ranged from 100.90 to 109.40%, and the relative standard deviation (RSD) for precision was less than 4%. Results from 10 samples, including process products, final products, and products from different manufacturers, demonstrated that the method was suitable for the quantitative detection of residual proteins in enzyme-catalyzed Reb M, providing technical support for the quality control of Reb M.
A new method has been established for determining trace amounts of platinum in water using ion liquid (IL)-dispersive liquid–liquid microextraction (DLLME) combined with graphite furnace atomic absorption spectroscopy (GFAAS). The method is based on the use of a self-prepared reagent, 5-(5-cyano-2-pyridineazo)-2,4-diaminotoluene (5-CN-PADAT), as a chelating agent, which reacts with Pt(IV) to form a hydrophobic chelate. The extraction solvent is 1-octyl-3-methylimidazolium hexafluorophosphate ([C8mim][PF6]), and ethyl acetate is used as the dispersive solvent. After the extraction is completed, the extraction phase formed by [C8mim][PF6] and ethyl acetate has a relatively low viscosity and can be directly used for the determination of GFAAS. A single-factor rotational method was employed to optimize conditions affecting DLLME extraction efficiency. The interactions among the factors affecting DLLME were analyzed using response surface optimization (RSM). Under optimal conditions, platinum concentrations exhibited good linearity within the range of 40–280 ng/mL, with a detection limit of 0.3 ng/mL. AGREEprep was used to discuss the ecological friendliness of the method, demonstrating its low cost, ease of operation, simple equipment requirements, and environmental friendliness. When applied to determining trace amounts of platinum in water samples, the results were satisfactory.